Dose and perceived image quality in chest radiography.

Wouter J H Veldkamp1, Lucia J M Kroft, Jacob Geleijns.   

Abstract

Chest radiography is the most commonly performed diagnostic X-ray examination. The radiation dose to the patient for this examination is relatively low but because of its frequent use, the contribution to the collective dose is considerable. Consequently, optimization of dose and image quality offers a challenging area of research. In this article studies on dose reduction, different detector technologies, optimization of image acquisition and new technical developments in image acquisition and post processing will be reviewed. Studies indicate that dose reduction in PA chest images to at least 50% of commonly applied dose levels does not affect diagnosis in the lung fields; however, dose reduction in the mediastinum, upper abdomen and retrocardiac areas appears to directly deteriorate diagnosis. In addition to patient dose, also the design of the various digital detectors seems to have an effect on image quality. With respect to image acquisition, studies showed that using a lower tube voltage improves visibility of anatomical structures and lesions in digital chest radiographs but also increases the disturbing appearance of ribs. New techniques that are currently being evaluated are dual energy, tomosynthesis, temporal subtraction and rib suppression. These technologies may improve diagnostic chest X-ray further. They may for example reduce the negative influence of over projection of ribs, referred to as anatomic noise. In chest X-ray this type of noise may be the dominating factor in the detection of nodules. In conclusion, optimization and new developments will enlarge the value of chest X-ray as a mainstay in the diagnosis of chest diseases.

Entities:  

Mesh:

Year:  2009        PMID: 19577393     DOI: 10.1016/j.ejrad.2009.05.039

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  16 in total

1.  Diagnostic value of routine chest radiography in febrile, neutropenic children for early detection of pneumonia and mould infections.

Authors:  Stefan D Roberts; Gregory M Wells; Nilay M Gandhi; Nowell R York; Gabriela Maron; Bassem Razzouk; Randall T Hayden; Sue C Kaste; Jerry L Shenep
Journal:  Support Care Cancer       Date:  2012-01-26       Impact factor: 3.603

2.  Optimization of the radiological protection of patients undergoing digital radiography.

Authors:  Menglong Zhang; Cunkun Chu
Journal:  J Digit Imaging       Date:  2012-02       Impact factor: 4.056

3.  [Dose reduction and adequate image quality in digital radiography: a contradiction?].

Authors:  S Pötter-Lang; M Dünkelmeyer; M Uffmann
Journal:  Radiologe       Date:  2012-10       Impact factor: 0.635

4.  Optimization of dual-energy subtraction chest radiography by use of a direct-conversion flat-panel detector system.

Authors:  Mari Fukao; Kiyosumi Kawamoto; Hiroaki Matsuzawa; Osamu Honda; Takeshi Iwaki; Tsukasa Doi
Journal:  Radiol Phys Technol       Date:  2014-08-15

5.  [Detection of lung nodules. New opportunities in chest radiography].

Authors:  S Pötter-Lang; S Schalekamp; C Schaefer-Prokop; M Uffmann
Journal:  Radiologe       Date:  2014-05       Impact factor: 0.635

6.  Development of a computer simulation technique for low-dose chest radiographs: a phantom study.

Authors:  Rie Murakami; Shigehiko Katsuragawa
Journal:  Radiol Phys Technol       Date:  2020-02-05

7.  Use of a digitally reconstructed radiograph-based computer simulation for the optimisation of chest radiographic techniques for computed radiography imaging systems.

Authors:  C S Moore; G Avery; S Balcam; L Needler; A Swift; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2012-01-17       Impact factor: 3.039

8.  Routine chest X-ray prior to thyroid surgery: is it always necessary?

Authors:  Brian W Hong; Haggi Mazeh; Herbert Chen; Rebecca S Sippel
Journal:  World J Surg       Date:  2012-11       Impact factor: 3.352

Review 9.  Routine chest x-rays in intensive care units: a systematic review and meta-analysis.

Authors:  Anusoumya Ganapathy; Neill K J Adhikari; Jamie Spiegelman; Damon C Scales
Journal:  Crit Care       Date:  2012-12-12       Impact factor: 9.097

10.  Correlation of clinical and physical-technical image quality in chest CT: a human cadaver study applied on iterative reconstruction.

Authors:  An De Crop; Peter Smeets; Tom Van Hoof; Merel Vergauwen; Tom Dewaele; Mathias Van Borsel; Eric Achten; Koenraad Verstraete; Katharina D'Herde; Hubert Thierens; Klaus Bacher
Journal:  BMC Med Imaging       Date:  2015-08-19       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.