Literature DB >> 26115773

Frequency domain analysis of cerebral near infrared spectroscopy signals during application of an impedance threshold device in spontaneously ventilating volunteers.

Douglas A Colquhoun1, Kimberly Naden2, Robert H Thiele3.   

Abstract

Currently available near infrared spectroscopy (NIRS) devices are unable to discriminate between arterial and venous blood, a potential source of artifact. The purpose of this study was to test the hypothesis that oscillations in NIR signals at the respiratory and cardiac frequency could be attributed to venous and arterial blood, respectively, and thereby isolated. After written informed consent was obtained, a two-wavelength NIRS device was placed over the left frontal cortex in 20 volunteers. After 5 min of unimpeded spontaneous ventilation, an impedance threshold device (ITD, average resistance-7 cm H2O) was applied and an additional two minutes of data recorded. Tissue saturation (StO2) calculated at the ventilatory and cardiac frequencies was compared to non-pulsatile StO2, before and after application of the ITD using spectral peak and power algorithms. The ITD increased non-pulsatile cerebral saturation by 3.6 %. The ITD had no discernable effect on pulsatile estimates of StO2 at either the ventilatory or cardiac frequencies. StO2 estimated at the NIRS spectral peak from 0.75 to 1.75 Hz was 24 % higher than non-pulsatile StO2 (p = 0.0013). There were no other significant differences between pulsatile and non-pulsatile algorithms in the estimation of StO2. In 64 % of cases, both the low (ventilator) and high (cardiac) frequency estimates of StO2 were either both larger or both smaller than non-pulsatile StO2, suggesting that they were interrogating the same vascular bed. Frequency domain analysis cannot reliably separate NIRS waveforms into arterial and venous components.

Entities:  

Keywords:  Cerebral oximetery; ITPR; Intra thoracic pressure; Monitoring; NIRS

Mesh:

Substances:

Year:  2015        PMID: 26115773     DOI: 10.1007/s10877-015-9729-0

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  32 in total

1.  The effect of the intrathoracic pressure regulator on hemodynamics and cardiac output.

Authors:  Julie L Huffmyer; Danja S Groves; David C Scalzo; Duncan G DeSouza; Keith E Littlewood; Robert H Thiele; Edward C Nemergut
Journal:  Shock       Date:  2011-02       Impact factor: 3.454

2.  Impact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies.

Authors:  Sophie N Davie; Hilary P Grocott
Journal:  Anesthesiology       Date:  2012-04       Impact factor: 7.892

3.  Oscillations in the plethysmographic waveform amplitude: phenomenon hides behind artifacts.

Authors:  Maxime Cannesson; Aymen A Awad; Kirk Shelley
Journal:  Anesthesiology       Date:  2009-07       Impact factor: 7.892

Review 4.  Peripheral venous pressure waveform.

Authors:  Richa Wardhan; Kirk Shelley
Journal:  Curr Opin Anaesthesiol       Date:  2009-12       Impact factor: 2.706

5.  Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a "gray zone" approach.

Authors:  Maxime Cannesson; Yannick Le Manach; Christoph K Hofer; Jean Pierre Goarin; Jean-Jacques Lehot; Benoît Vallet; Benoît Tavernier
Journal:  Anesthesiology       Date:  2011-08       Impact factor: 7.892

Review 6.  Review article: cerebral near-infrared spectroscopy in adults: a work in progress.

Authors:  Arnab Ghosh; Clare Elwell; Martin Smith
Journal:  Anesth Analg       Date:  2012-11-09       Impact factor: 5.108

7.  Radial-femoral concordance in time and frequency domain-based estimates of systemic arterial respiratory variation.

Authors:  Robert H Thiele; Douglas A Colquhoun; Jason M Tucker-Schwartz; George T Gillies; Marcel E Durieux
Journal:  J Clin Monit Comput       Date:  2012-08-19       Impact factor: 2.502

8.  Characterization of the near infrared absorption spectra of cytochrome aa3 and haemoglobin for the non-invasive monitoring of cerebral oxygenation.

Authors:  S Wray; M Cope; D T Delpy; J S Wyatt; E O Reynolds
Journal:  Biochim Biophys Acta       Date:  1988-03-30

9.  Phenylephrine does not reduce cerebral perfusion during canine cardiopulmonary bypass.

Authors:  W E Johnston; D S DeWitt; J Vinten-Johansen; D A Stump; D S Prough
Journal:  Anesth Analg       Date:  1994-07       Impact factor: 5.108

10.  Inspiratory resistance delays the reporting of symptoms with central hypovolemia: association with cerebral blood flow.

Authors:  Caroline A Rickards; Kathy L Ryan; William H Cooke; Keith G Lurie; Victor A Convertino
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2007-05-16       Impact factor: 3.619

View more
  1 in total

Review 1.  Journal of clinical monitoring and computing 2016 end of year summary: monitoring cerebral oxygenation and autoregulation.

Authors:  Thomas W L Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2017-01-24       Impact factor: 2.502