Literature DB >> 21700890

Peripheral vascular decoupling in porcine endotoxic shock.

Feras Hatib1, Jos R C Jansen, Michael R Pinsky.   

Abstract

Cardiac output measurement from arterial pressure waveforms presumes a defined relationship between the arterial pulse pressure (PP), vascular compliance (C), and resistance (R). Cardiac output estimates degrade if these assumptions are incorrect. We hypothesized that sepsis would differentially alter central and peripheral vasomotor tone, decoupling the usual pressure wave propagation from central to peripheral sites. We assessed arterial input impedance (Z), C, and R from central and peripheral arterial pressures, and aortic blood flow in an anesthetized porcine model (n = 19) of fluid resuscitated endotoxic shock induced by endotoxin infusion (7 μg·kg⁻¹·h⁻¹ increased to 14 and 20 μg·kg⁻¹·h⁻¹ every 10 min and stopped when mean arterial pressure <40 mmHg or Sv(O₂) < 45%). Aortic, femoral, and radial artery pressures and aortic and radial artery flows were measured. Z was calculated by FFT of flow and pressure data. R and C were derived using a two-element Windkessel model. Arterial PP increased from aortic to femoral and radial sites. During stable endotoxemia with fluid resuscitation, aortic and radial blood flows returned to or exceeded baseline while mean arterial pressure remained similarly decreased at all three sites. However, aortic PP exceeded both femoral and radial arterial PP. Although Z, R, and C derived from aortic and radial pressure and aortic flow were similar during baseline, Z increases and C decreases when derived from aortic pressure whereas Z decreases and C increases when derived from radial pressure, while R decreased similarly with both pressure signals. This central-to-peripheral vascular tone decoupling, as quantified by the difference in calculated Z and C from aortic and radial artery pressure, may explain the decreasing precision of peripheral arterial pressure profile algorithms in assessing cardiac output in septic shock patients and suggests that different algorithms taking this vascular decoupling into account may be necessary to improve their precision in this patient population.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21700890      PMCID: PMC3174791          DOI: 10.1152/japplphysiol.00066.2011

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  27 in total

Review 1.  Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology.

Authors:  John C Chaney; Stephen Derdak
Journal:  Crit Care Med       Date:  2002-10       Impact factor: 7.598

2.  The measurement of the stroke volume from the pressure pulse.

Authors:  W F HAMILTON; J W REMINGTON
Journal:  Am J Physiol       Date:  1947-01

3.  Nitric oxide metabolism in canine sepsis: relation to regional blood flow.

Authors:  K Tanigawa; R Bellomo; J A Kellum; Y M Kim; H Zar; J R Lancaster; M R Pinsky; B Ondulick
Journal:  J Crit Care       Date:  1999-12       Impact factor: 3.425

4.  Estimation of total arterial compliance: an improved method and evaluation of current methods.

Authors:  Z Liu; K P Brin; F C Yin
Journal:  Am J Physiol       Date:  1986-09

5.  The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model.

Authors:  G J Langewouters; K H Wesseling; W J Goedhard
Journal:  J Biomech       Date:  1984       Impact factor: 2.712

6.  A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients.

Authors:  J R Jansen; J J Schreuder; J P Mulier; N T Smith; J J Settels; K H Wesseling
Journal:  Br J Anaesth       Date:  2001-08       Impact factor: 9.166

7.  Aortic input impedance in infants and children.

Authors:  M K Sharp; G M Pantalos; L Minich; L Y Tani; E C McGough; J A Hawkins
Journal:  J Appl Physiol (1985)       Date:  2000-06

8.  Deep hypothermic circulatory arrest and the femoral-to-radial arterial pressure gradient.

Authors:  Gerard R Manecke; Michael Parimucha; Greg Stratmann; William C Wilson; David M Roth; William R Auger; Kim M Kerr; Stuart W Jamieson; David P Kapelanski; Mark M Mitchell
Journal:  J Cardiothorac Vasc Anesth       Date:  2004-04       Impact factor: 2.628

9.  Stroke volume--pulse pressure relationships in borderline hypertension: a possible indicator of decreased arterial compliance.

Authors:  J J Ferguson; S Julius; O S Randall
Journal:  J Hypertens Suppl       Date:  1984-12

10.  Input impedance of the systemic circulation in man.

Authors:  W W Nichols; C R Conti; W E Walker; W R Milnor
Journal:  Circ Res       Date:  1977-05       Impact factor: 17.367

View more
  31 in total

1.  Continuous cardiac output measurement by un-calibrated pulse wave analysis and pulmonary artery catheter in patients with septic shock.

Authors:  Michael T Ganter; Jamal A Alhashemi; Adel M Al-Shabasy; Ursina M Schmid; Peter Schott; Sanaa A Shalabi; Ahmed M Badri; Sonja Hartnack; Christoph K Hofer
Journal:  J Clin Monit Comput       Date:  2015-02-27       Impact factor: 2.502

2.  Can changes in arterial pressure be used to detect changes in cardiac index during fluid challenge in patients with septic shock?

Authors:  Charalampos Pierrakos; Dimitrios Velissaris; Sabino Scolletta; Sarah Heenen; Daniel De Backer; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2012-01-26       Impact factor: 17.440

3.  Effects of fluid administration on arterial load in septic shock patients.

Authors:  Manuel Ignacio Monge García; Pedro Guijo González; Manuel Gracia Romero; Anselmo Gil Cano; Chris Oscier; Andrew Rhodes; Robert Michael Grounds; Maurizio Cecconi
Journal:  Intensive Care Med       Date:  2015-06-11       Impact factor: 17.440

4.  Rebuttal to: "As simple as possible, but not simpler: estimating the effective arterial elastance at bedside".

Authors:  Manuel Ignacio Monge Garcia; Zhongping Jian; Jos J Settels; Feras Hatib; Maurizio Cecconi; Michael R Pinsky
Journal:  J Clin Monit Comput       Date:  2019-02-14       Impact factor: 2.502

5.  Reliability of effective arterial elastance using peripheral arterial pressure as surrogate for left ventricular end-systolic pressure.

Authors:  Manuel Ignacio Monge Garcia; Zhongping Jian; Jos J Settels; Feras Hatib; Maurizio Cecconi; Michael R Pinsky
Journal:  J Clin Monit Comput       Date:  2018-12-14       Impact factor: 2.502

6.  Intensive care medicine in 2050: NEWS for hemodynamic monitoring.

Authors:  Frederic Michard; Michael R Pinsky; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2017-01-25       Impact factor: 17.440

7.  The future of intraoperative blood pressure management.

Authors:  Frederic Michard; Ngai Liu; Andrea Kurz
Journal:  J Clin Monit Comput       Date:  2017-02-07       Impact factor: 2.502

8.  Beta-blockers in septic shock to optimize hemodynamics? We are not sure.

Authors:  Daniel De Backer; Djillali Annane
Journal:  Intensive Care Med       Date:  2016-06-27       Impact factor: 17.440

9.  Heart rate reduction may be a major determinant of vascular tone in esmolol-treated septic shock patients-although still remains to be confirmed!

Authors:  Antoine Kimmoun; Chaoije Wei; Bruno Levy; Djillali Annane
Journal:  J Thorac Dis       Date:  2016-08       Impact factor: 2.895

10.  Assessment of left ventricular function by pulse wave analysis in critically ill patients.

Authors:  Sabino Scolletta; Laurent Bodson; Katia Donadello; Fabio S Taccone; Alessandro Devigili; Jean-Louis Vincent; Daniel De Backer
Journal:  Intensive Care Med       Date:  2013-03-09       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.