Literature DB >> 23474659

Assessment of left ventricular function by pulse wave analysis in critically ill patients.

Sabino Scolletta1, Laurent Bodson, Katia Donadello, Fabio S Taccone, Alessandro Devigili, Jean-Louis Vincent, Daniel De Backer.   

Abstract

PURPOSE: Left ventricular (LV) performance is often quantified by echocardiography in critically ill patients. Pulse wave analysis (PWA) systems can also monitor cardiac function but in a continuous fashion. We compared echocardiographic and PWA-derived indices of LV function.
METHODS: We enrolled 70 critically ill patients equipped with invasive arterial pressure monitoring who required echocardiography. We simultaneously assessed LV ejection fraction (LVEF), the rate of LV pressure rise during systole (dP/dt MAX) obtained with echocardiography (EC-dP/dt MAX), the ratio of effective arterial elastance to LV end-systolic elastance (E a/E es) determined by echocardiography, the dP/dt MAX estimated from the arterial pressure waveform (AP-dP/dt MAX) and the cardiac cycle efficiency (CCE) using PWA.
RESULTS: Mean LVEF was 53 ± 18 % and CCE 0.16 ± 0.26. CCE was correlated linearly with LVEF (r = 0.88, 95 % CI 0.81 to 0.92, P < 0.001), and the dP/dt MAX values from the two techniques were linearly correlated (r = 0.93, 95 % CI 0.87 to 0.96, P < 0.001). There was minimal bias between the techniques for measurement of dP/dt MAX (23.7 mmHg/ms; 95 % CI -23.6 to 71.0). E a/E es and CCE were inversely correlated (r = -0.81, 95 % CI -0.88 to -0.71, P < 0.001). A CCE value of <0.07 predicted LVEF <40 % with a sensitivity of 0.93 and a specificity of 0.96 (AUC 0.98, 95 % CI 0.90 to 1.0, P < 0.001). A CCE value of >0.12 predicted LVEF ≥50 % with a sensitivity of 0.96 and a specificity of 0.82 (AUC 0.94, 95 % CI 0.87 to 1.0, P < 0.001). A CCE value <0.12 predicted E a/E es ≥1.3 with a sensitivity of 0.93 and a specificity of 0.89 (AUC 0.94, 95 % CI 0.83 to 1.0, P < 0.001).
CONCLUSIONS: PWA-derived variables provide relevant information on cardiac contractility and performance in critically ill patients. PWA provides an easy method for online hemodynamic evaluation in critically ill patients.

Entities:  

Mesh:

Year:  2013        PMID: 23474659     DOI: 10.1007/s00134-013-2861-8

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  52 in total

Review 1.  Cardiac energetics: from E(max) to pressure-volume area.

Authors:  Hiroyuki Suga
Journal:  Clin Exp Pharmacol Physiol       Date:  2003-08       Impact factor: 2.557

2.  Dynamic response of liquid-filled catheter systems for measurement of blood pressure: precision of measurements and reliability of the Pressure Recording Analytical Method with different disposable systems.

Authors:  Stefano Romagnoli; Salvatore Mario Romano; Sergio Bevilacqua; Chiara Lazzeri; Gian Franco Gensini; Carlo Pratesi; Diego Quattrone; Daniele Dini; Angelo Raffaele De Gaudio
Journal:  J Crit Care       Date:  2010-10-30       Impact factor: 3.425

3.  Non-invasive radial pulse wave assessment for the evaluation of left ventricular systolic performance in heart failure.

Authors:  Jean-Michel Tartiere; Damien Logeart; Florence Beauvais; Christophe Chavelas; Lamia Kesri; Jean-Yves Tabet; Alain Cohen-Solal
Journal:  Eur J Heart Fail       Date:  2007-01-23       Impact factor: 15.534

Review 4.  Quantitative left ventricular systolic function: from chamber to myocardium.

Authors:  Nathaniel Dittoe; David Stultz; Brian P Schwartz; Harvey S Hahn
Journal:  Crit Care Med       Date:  2007-08       Impact factor: 7.598

Review 5.  Ejection fraction revisited.

Authors:  J L Robotham; M Takata; M Berman; Y Harasawa
Journal:  Anesthesiology       Date:  1991-01       Impact factor: 7.892

6.  Contractile strength and mechanical efficiency of left ventricle are enhanced by physiological afterload.

Authors:  D Burkhoff; P P de Tombe; W C Hunter; D A Kass
Journal:  Am J Physiol       Date:  1991-02

7.  Left ventricular-arterial coupling relations in the normal human heart.

Authors:  M R Starling
Journal:  Am Heart J       Date:  1993-06       Impact factor: 4.749

8.  Cardiac function index provided by transpulmonary thermodilution behaves as an indicator of left ventricular systolic function.

Authors:  Julien Jabot; Xavier Monnet; Lamia Bouchra; Denis Chemla; Christian Richard; Jean-Louis Teboul
Journal:  Crit Care Med       Date:  2009-11       Impact factor: 7.598

9.  The left ventricular dP/dtmax-end-diastolic volume relation in closed-chest dogs.

Authors:  W C Little
Journal:  Circ Res       Date:  1985-06       Impact factor: 17.367

10.  Assessing left ventricular systolic function in shock: evaluation of echocardiographic parameters in intensive care.

Authors:  Lill Bergenzaun; Petri Gudmundsson; Hans Öhlin; Joachim Düring; Anders Ersson; Lilian Ihrman; Ronnie Willenheimer; Michelle S Chew
Journal:  Crit Care       Date:  2011-08-16       Impact factor: 9.097

View more
  19 in total

1.  The effect of variable arterial transducer level on the accuracy of pulse contour waveform-derived measurements in critically ill patients.

Authors:  Huai-Wu He; Da-Wei Liu; Yun Long; Xiao-Ting Wang; Mei-Ling Zhao; Xiao-Li Lai
Journal:  J Clin Monit Comput       Date:  2015-08-23       Impact factor: 2.502

2.  Assessment of cardiac function in infants with transposition of the great arteries after surgery: comparison of two methods.

Authors:  Fan Yang; Roberta Iacobelli; Jian-Ming Wang; Fiore Salvatore Iorio
Journal:  World J Pediatr       Date:  2018-07-30       Impact factor: 2.764

3.  Heart rate reduction with esmolol is associated with improved arterial elastance in patients with septic shock: a prospective observational study.

Authors:  A Morelli; M Singer; V M Ranieri; A D'Egidio; L Mascia; A Orecchioni; F Piscioneri; F Guarracino; E Greco; M Peruzzi; G Biondi-Zoccai; G Frati; S M Romano
Journal:  Intensive Care Med       Date:  2016-04-21       Impact factor: 17.440

4.  Beta-blockers in septic shock: a magnifying glass on the relation heart vessel.

Authors:  Calypso Mathieu; Laurent Zieleskiewicz; Marc Leone
Journal:  J Thorac Dis       Date:  2016-08       Impact factor: 2.895

5.  Development of a Standard Protocol for the Harmonic Analysis of Radial Pulse Wave and Assessing Its Reliability in Healthy Humans.

Authors:  Chi-Wei Chang; Jiang-Ming Chen; Wei-Kung Wang
Journal:  IEEE J Transl Eng Health Med       Date:  2015-10-14       Impact factor: 3.316

Review 6.  Prediction and Prevention of Intraoperative Hypotension with the Hypotension Prediction Index: A Narrative Review.

Authors:  Tatiana Sidiropoulou; Marina Tsoumpa; Panayota Griva; Vasiliki Galarioti; Paraskevi Matsota
Journal:  J Clin Med       Date:  2022-09-22       Impact factor: 4.964

7.  Pressure response to fluid challenge administration in hypotensive surgical patients: a post-hoc pharmacodynamic analysis of five datasets.

Authors:  Antonio Messina; Davide Colombo; Giulia Lionetti; Lorenzo Calabrò; Katerina Negri; Chiara Robba; Gianmaria Cammarota; Elena Costantini; Maurizio Cecconi
Journal:  J Clin Monit Comput       Date:  2022-10-05       Impact factor: 1.977

8.  Predicting fluid responsiveness in 100 critically ill children: the effect of baseline contractility.

Authors:  Rohit Saxena; Andrew Durward; Sarah Steeley; Ian A Murdoch; Shane M Tibby
Journal:  Intensive Care Med       Date:  2015-09-28       Impact factor: 17.440

9.  Ejection fractions and pressure-heart rate product to evaluate cardiac efficiency. Continuous, real-time diagnosis using blood pressure and heart rate.

Authors:  H Kunig; P Tassani-Prell; L Engelmann
Journal:  Med Klin Intensivmed Notfmed       Date:  2013-09-14       Impact factor: 0.840

10.  Year in review in Intensive Care Medicine 2013: I. Acute kidney injury, ultrasound, hemodynamics, cardiac arrest, transfusion, neurocritical care, and nutrition.

Authors:  Giuseppe Citerio; Jan Bakker; Matteo Bassetti; Dominique Benoit; Maurizio Cecconi; J Randall Curtis; Glenn Hernandez; Margaret Herridge; Samir Jaber; Michael Joannidis; Laurent Papazian; Mark Peters; Pierre Singer; Martin Smith; Marcio Soares; Antoni Torres; Antoine Vieillard-Baron; Jean-François Timsit; Elie Azoulay
Journal:  Intensive Care Med       Date:  2013-12-13       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.