Literature DB >> 21641179

Detection of periprosthetic osteolysis around total knee arthroplasties an in vitro study.

Mario G T Zotti1, David G Campbell, Richard Woodman.   

Abstract

Periprosthetic osteolysis is a common cause of revision of total knee arthroplasties (TKAs), with plain anteroposterior and lateral (APL) radiographs being the most common method for screening. The aim of this study was to examine the utility of lesion detection and volume appreciation with APL, paired oblique radiographs, and computed tomography. Defects of different sizes were created in 3 cadaveric knees with a cementless TKA in situ and imaged with APL, oblique, and computed tomography modalities. The resultant images were then shown to 3 arthroplasty surgeons, and the absence or presence of lesions, volume size, and confidence in assessment were recorded. The results suggest that the current practice of APL is inferior for the assessment of periprosthetic osteolysis around TKA. Crown
Copyright © 2012. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 21641179     DOI: 10.1016/j.arth.2011.03.047

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients.

Authors:  Hao Tang; Dejin Yang; Shengjie Guo; Jing Tang; Jian Liu; Dacheng Wang; Yixin Zhou
Journal:  Skeletal Radiol       Date:  2016-09-02       Impact factor: 2.199

2.  Usefulness of slice encoding for metal artifact correction (SEMAC) technique for reducing metal artifacts after total knee arthroplasty.

Authors:  Ahmed Jawhar; Miriam Reichert; Michael Kostrzewa; Mathias Nittka; Ulrike Attenberger; Henning Roehl; Frederic Bludau
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-10-11

3.  Evaluation of peri-prosthetic radiolucent lines surrounding the cementless femoral stem using digital tomosynthesis with metal artifact reduction: a cadaveric study in comparison with radiography and computed tomography.

Authors:  Hao Tang; Xingjian Huang; Xiaoguang Cheng; Dejin Yang; Yong Huang; Yixin Zhou
Journal:  Quant Imaging Med Surg       Date:  2020-09

4.  Dual-energy CT and ceramic or titanium prostheses material reduce CT artifacts and provide superior image quality of total knee arthroplasty.

Authors:  Maximilian F Kasparek; Michael Töpker; Mathias Lazar; Michael Weber; Michael Kasparek; Thomas Mang; Paul Apfaltrer; Bernd Kubista; Reinhard Windhager; Helmut Ringl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-06-07       Impact factor: 4.342

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.