Literature DB >> 21621979

Assessment of linear measurements of bone for implant sites in the presence of metallic artefacts using cone beam computed tomography and multislice computed tomography.

C C Cremonini1, M Dumas, C M Pannuti, J B C Neto, M G P Cavalcanti, L A Lima.   

Abstract

The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p>0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p>0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.
Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21621979     DOI: 10.1016/j.ijom.2011.04.015

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  14 in total

1.  Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode.

Authors:  K Kamburoglu; E Kolsuz; S Murat; H Eren; S Yüksel; C S Paksoy
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

2.  Comparison of mesiodistal space measurements of single-implant sites on panoramic and oblique images generated by cone-beam CT.

Authors:  Mustafa Alkhader; Malik Hudieb
Journal:  Surg Radiol Anat       Date:  2013-08-27       Impact factor: 1.246

3.  Metal and motion artifacts by cone beam computed tomography (CBCT) in dental and maxillofacial study.

Authors:  Cosimo Nardi; Claudia Borri; Francesco Regini; Linda Calistri; Alessandro Castellani; Chiara Lorini; Stefano Colagrande
Journal:  Radiol Med       Date:  2015-01-30       Impact factor: 3.469

4.  Accuracy of CBCT images in the assessment of buccal marginal alveolar peri-implant defects: effect of field of view.

Authors:  K Kamburoğlu; S Murat; C Kılıç; S Yüksel; H Avsever; A Farman; W C Scarfe
Journal:  Dentomaxillofac Radiol       Date:  2014-03-20       Impact factor: 2.419

5.  Evaluation of the Metal Artifact Caused by Dental Implants in Cone Beam Computed Tomography Images.

Authors:  Nazmehr Vahdani; Ehsan Moudi; Fatemeh Ghobadi; Ebrahim Mohammadi; Ali Bijani; Sina Haghanifar
Journal:  Maedica (Bucur)       Date:  2020-06

6.  Effect of anatomical region on the formation of metal artefacts produced by dental implants in cone beam computed tomographic images.

Authors:  Alessiana Helena Machado; Karolina Aparecida Castilho Fardim; Camila Furtado de Souza; Bruno Salles Sotto-Maior; Neuza Maria Souza Picorelli Assis; Karina Lopes Devito
Journal:  Dentomaxillofac Radiol       Date:  2018-01-10       Impact factor: 2.419

7.  An exploratory study into measuring the cortical bone thickness from CT in the presence of metal implants.

Authors:  Tristan Whitmarsh; Graham M Treece; Andrew H Gee; Kenneth E S Poole
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-23       Impact factor: 2.924

8.  Evaluation of metal artefacts for two CBCT devices with a new dental arch phantom.

Authors:  Luciano Augusto Cano Martins; Polyane Mazucatto Queiroz; Yuri Nejaim; Karla de Faria Vasconcelos; Francisco Carlos Groppo; Francisco Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2020-03-16       Impact factor: 2.419

9.  Influence of windowing and metal artefact reduction algorithms on the volumetric dimensions of five different high-density materials: a cone-beam CT study.

Authors:  Fernanda Coelho-Silva; Luciano Augusto Cano Martins; Daniela Azeredo Braga; Eliana Zandonade; Francisco Haiter-Neto; Sergio Lins de-Azevedo-Vaz
Journal:  Dentomaxillofac Radiol       Date:  2020-06-25       Impact factor: 2.419

10.  Distortion or magnification? An in vitro cone-beam CT study of dimensional changes of objects with different compositions.

Authors:  Fernanda Coelho-Silva; Hugo Gaêta-Araujo; Lucas P Lopes Rosado; Deborah Queiroz Freitas; Francisco Haiter-Neto; Sergio Lins de-Azevedo-Vaz
Journal:  Dentomaxillofac Radiol       Date:  2021-06-16       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.