Literature DB >> 32952687

Evaluation of the Metal Artifact Caused by Dental Implants in Cone Beam Computed Tomography Images.

Nazmehr Vahdani1, Ehsan Moudi2, Fatemeh Ghobadi1, Ebrahim Mohammadi1, Ali Bijani3, Sina Haghanifar2.   

Abstract

Statement of the problem: The presence of a metal object such as dental implants in the scan field may cause artifacts on the cone-beam computed tomography (CBCT) images, which can reduce the diagnostic quality and accuracy of images. Purpose: The aim of this in vitro study was to compare the severity of implant-induced metal artifacts on CBCT images. Materials and method: To this end, a dry human mandible and a maxilla were selected, then two Roxolid and two Zirconium fixtures with different diameters were placed in the central incisor and first molar sockets and fixed with dental wax. The mandible and maxilla were placed in the simulated phantom for soft tissue, and the occlusal plane was adjusted parallel to the horizon. Images were taken at standard and high resolutions using two CBCT units. The CBCT gray values were measured in three longitudinal sections of the fixture (cervical, middle and apical) and the contrast noise ratio (CNR) was calculated. The CNR values of images were analyzed based on the fixture material, resolution, jaw, unit parameters and fixture size by using the paired t-test and different fixture sections by one-way ANOVA.
Results: Depending on the CBCT unit, the CNR values in Roxolid and Zirconium fixtures are completely different. Under higher exposure parameters, the CNR values of the Roxolid and Zirconium fixtures were significantly higher in the maxilla than mandible. However, the fixture size and longitudinal section type did not have a significant effect on the CNR values.
Conclusion: In contrast to the fixture material, scanning parameters and jaw type, differences in the size and longitudinal section of the fixtures had no impact on artifact severity.

Entities:  

Year:  2020        PMID: 32952687      PMCID: PMC7482696          DOI: 10.26574/maedica.2020.15.2.224

Source DB:  PubMed          Journal:  Maedica (Bucur)        ISSN: 1841-9038


  17 in total

1.  On cone-beam computed tomography artifacts induced by titanium implants.

Authors:  Ralf Kurt Willy Schulze; Dorothea Berndt; Bernd d'Hoedt
Journal:  Clin Oral Implants Res       Date:  2009-10-21       Impact factor: 5.977

Review 2.  Cone beam computed tomography in implant dentistry: a systematic review focusing on guidelines, indications, and radiation dose risks.

Authors:  Michael M Bornstein; William C Scarfe; Vida M Vaughn; Reinhilde Jacobs
Journal:  Int J Oral Maxillofac Implants       Date:  2014       Impact factor: 2.804

3.  Effect of anatomical region on the formation of metal artefacts produced by dental implants in cone beam computed tomographic images.

Authors:  Alessiana Helena Machado; Karolina Aparecida Castilho Fardim; Camila Furtado de Souza; Bruno Salles Sotto-Maior; Neuza Maria Souza Picorelli Assis; Karina Lopes Devito
Journal:  Dentomaxillofac Radiol       Date:  2018-01-10       Impact factor: 2.419

Review 4.  Is there a consensus for CBCT use in Orthodontics?

Authors:  Daniela G Garib; Louise Resti Calil; Claudia Resende Leal; Guilherme Janson
Journal:  Dental Press J Orthod       Date:  2014 Sep-Oct

5.  Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study.

Authors:  Ralf Smeets; Maximilian Schöllchen; Tobias Gauer; Ghazal Aarabi; Alexandre T Assaf; Carsten Rendenbach; Benedicta Beck-Broichsitter; Jan Semmusch; Jan Sedlacik; Max Heiland; Jens Fiehler; Susanne Siemonsen
Journal:  Dentomaxillofac Radiol       Date:  2016-12-02       Impact factor: 2.419

6.  Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT.

Authors:  X-Y Gong; E Meyer; X-J Yu; J-H Sun; L-P Sheng; K-H Huang; R-Z Wu
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

7.  Influence of anatomical location on CT numbers in cone beam computed tomography.

Authors:  Matheus L Oliveira; Guilherme M Tosoni; David H Lindsey; Kristopher Mendoza; Sotirios Tetradis; Sanjay M Mallya
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2013-04

8.  Effect of Exposure Parameters on Metal Artifacts in Cone Beam Computed Tomography.

Authors:  Mehrdad Panjnoush; Yasaman Kheirandish; Pooneh Mohseni Kashani; Hoorieh Bashizadeh Fakhar; Farzan Younesi; Maysa Mallahi
Journal:  J Dent (Tehran)       Date:  2016-06

9.  The effect of metal artifacts on the identification of vertical root fractures using different fields of view in cone-beam computed tomography.

Authors:  Ehsan Moudi; Sina Haghanifar; Zahrasadat Madani; Ali Bijani; Zeynab Sadat Nabavi
Journal:  Imaging Sci Dent       Date:  2015-09-09

10.  Comparing the precision of panoramic radiography and cone-beam computed tomography in avoiding anatomical structures critical to dental implant surgery: A retrospective study.

Authors:  Öznur Özalp; Hüseyin Alican Tezerişener; Burak Kocabalkan; Ulviye Şebnem Büyükkaplan; Mehmet Mustafa Özarslan; Göksel Şimşek Kaya; Mehmet Ali Altay; Alper Sindel
Journal:  Imaging Sci Dent       Date:  2018-12-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.