Literature DB >> 10660175

Prosthesis-patient mismatch: hemodynamic comparison of stented and stentless aortic valves.

K L Yun1, W R Jamieson, S Khonsari, L H Burr, A I Munro, C F Sintek.   

Abstract

Several centers have reported excellent clinical performance of stentless aortic xenografts. This study reports a hemodynamic comparison of the Medtronic Freestyle stentless and Mosaic stented valves. The prosthetic hemodynamics at discharge and 1 year after insertion in 95 patients who underwent aortic valve replacement with the Freestyle stentless bioprosthesis at Southern California Kaiser Permanente Medical Center were compared retrospectively with 115 unmatched individuals who received the Mosaic stented valve at the University of British Columbia. As assessed by echocardiography, there were no differences in the mean transvalvular gradient, effective orifice area (EOA), or EOA indexed to body surface area (EOAI) at discharge between the two groups. However, after 1 year, all corresponding Freestyle valve sizes had larger EOAs and lower gradients. Furthermore, fewer patients receiving Freestyle xenografts had prosthesis-patient mismatch (19% vs. 64%, P<.001) as defined by EOAI <0.85 cm2/m2. Although the Mosaic stented valve provides comparable immediate hemodynamic performance after implantation, there is significant improvement with the Freestyle bioprosthesis in terms of gradient, EOA, and prosthetic-patient mismatch at 1 year.

Entities:  

Mesh:

Year:  1999        PMID: 10660175

Source DB:  PubMed          Journal:  Semin Thorac Cardiovasc Surg        ISSN: 1043-0679


  4 in total

Review 1.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

2.  [Risk of perioperative mortality and complications following biological aortic valve replacement in elderly patients: stented vs unstented bioprotheses].

Authors:  J Ennker; I Florath; U Rosendahl; S Bauer; E von Hodenberg; I C Ennker
Journal:  Z Kardiol       Date:  2001-12

Review 3.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

4.  Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle stentless bioprosthesis and its consequences: a follow-up study in 587 patients.

Authors:  Alexander Albert; Ines Florath; Ulrich Rosendahl; Wael Hassanein; Eberhard V Hodenberg; Stefan Bauer; Ina Ennker; Jürgen Ennker
Journal:  J Cardiothorac Surg       Date:  2007-10-05       Impact factor: 1.637

  4 in total