CT attenuation measurements are valuable to discriminate pledgets used in prosthetic heart valve implantation from paravalvular leakage.

J Habets1, T S Meijer, R C A Meijer, W P Th M Mali, E-J P A Vonken, R P J Budde.   

Abstract

OBJECTIVES: Sutures with polytetrafluorethylene (PTFE) felt pledgets are commonly used in prosthetic heart valve (PHV) implantation. Paravalvular leakage can be difficult to distinguish from PTFE felt pledgets on multislice CT because both present as hyperdense structures. We assessed whether pledgets can be discriminated from contrast-enhanced solutions (blood/saline) on CT images based on attenuation difference in an ex vivo experiment and under in vivo conditions.
METHODS: PTFE felt pledgets were sutured to the suture ring of a mechanical PHV and porcine aortic annulus, and immersed and scanned in four different contrast-enhanced (Ultravist®; 300 mg jopromide ml(-1)) saline concentrations (10.0, 12.0, 13.6 and 15.0 mg ml(-1)). Scanning was performed on a 256-slice scanner with eight different scan protocols with various tube voltage (100 kV, 120 kV) and tube current (400 mAs, 600 mAs, 800 mAs, 1000 mAs) settings. Attenuation of the pledgets and surrounding contrast-enhanced saline were measured. Additionally, the attenuation of pledgets and contrast-enhanced blood was measured on electrocardiography (ECG)-gated CTA scans of 19 patients with 22 PHVs.
RESULTS: Ex vivo CT attenuation differences between the pledgets and contrast-enhanced solutions were larger by using higher tube voltages. CT attenuation values of the pledgets were higher than contrast-enhanced blood in patients: 420±26 Hounsfield units (mean±SD, range 383-494) and 288±41 Hounsfield units (range 202-367), respectively.
CONCLUSIONS: PTFE felt pledgets have consistently higher attenuation than surrounding contrast-enhanced blood. CT attenuation measurements therefore may help to differentiate pledgets from paravalvular leakage, and detect paravalvular leakage in patients with suspected PHV dysfunction.

Entities:  

Mesh:

Year:  2012        PMID: 22919014      PMCID: PMC3487076          DOI: 10.1259/bjr/29602784

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  10 in total

1.  Paravalvular leakage after mitral valve replacement: improved long-term survival with aggressive surgery?

Authors:  M Genoni; D Franzen; P Vogt; B Seifert; R Jenni; A Künzli; U Niederhäuser; M Turina
Journal:  Eur J Cardiothorac Surg       Date:  2000-01       Impact factor: 4.191

2.  Percutaneous closure of mitral paravalvular leak.

Authors:  Jean-François Piéchaud
Journal:  J Interv Cardiol       Date:  2003-04       Impact factor: 2.279

Review 3.  Will heart valve tissue engineering change the world?

Authors:  M H Yacoub; J J M Takkenberg
Journal:  Nat Clin Pract Cardiovasc Med       Date:  2005-02

4.  A new technique for cardiac valve replacement.

Authors:  O Gago; M M Kirsh
Journal:  Chest       Date:  1972-06       Impact factor: 9.410

5.  Evaluation of suture techniques for mitral valve replacement.

Authors:  J R Newton; D D Glower; J W Davis; J S Rankin
Journal:  J Thorac Cardiovasc Surg       Date:  1984-08       Impact factor: 5.209

6.  Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up.

Authors:  L S Rallidis; I E Moyssakis; I Ikonomidis; P Nihoyannopoulos
Journal:  Am Heart J       Date:  1999-08       Impact factor: 4.749

Review 7.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

8.  Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography.

Authors:  A Ionescu; A G Fraser; E G Butchart
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

9.  Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard.

Authors:  I-Chen Tsai; Yung-Kai Lin; Yen Chang; Yun-Ching Fu; Chung-Chi Wang; Shih-Rong Hsieh; Hao-Ji Wei; Hung-Wen Tsai; Sheng-Ling Jan; Kuo-Yang Wang; Min-Chi Chen; Clayton Chi-Chang Chen
Journal:  Eur Radiol       Date:  2008-11-27       Impact factor: 5.315

10.  Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients.

Authors:  Jesse Habets; Petr Symersky; Lex A van Herwerden; Bas A J M de Mol; Anje M Spijkerboer; Willem P Th M Mali; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2011-01-29       Impact factor: 5.315

  10 in total
  1 in total

1.  Advanced CT acquisition protocol with a third-generation dual-source CT scanner and iterative reconstruction technique for comprehensive prosthetic heart valve assessment.

Authors:  Marguerite E Faure; Laurens E Swart; Marcel L Dijkshoorn; Jos A Bekkers; Marcel van Straten; Koen Nieman; Paul M Parizel; Gabriel P Krestin; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2017-12-12       Impact factor: 5.315

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.