Literature DB >> 21586877

Evaluation of the Perkins handheld applanation tonometer in horses and cattle.

Silvia Franco Andrade1, Daniel Silva Kupper, Luiz Fernando Rodrigues Pinho, Elizabeth Cunha Franco, Marcus Vinícius Felix Fabri Prataviera, Rodrigo Rolim Duarte, José Ricardo Cecílio Junqueira.   

Abstract

The objective of this study was to evaluate and validate the accuracy of the Perkins handheld applanation tonometer for measuring intraocular pressure (IOP) in horses and cattle. Both eyes of 10 adult horses and cattle were evaluated in a postmortem study. The eyes from 10 clinically normal adult horses and cattle were also examined after bilateral auriculopalpebral nerve block and topical anesthesia for an in vivo study. IOP was measured postmortem using direct manometry (measured with an aneroid manometer) and tonometry (measured with a Perkins handheld applanation tonometer). The correlation coefficients (r(2)) for the data from the postmortem manometry and Perkins tonometer study were 0.866 for horses and 0.864 for cattle. In the in vivo study, IOP in horses was 25.1 ± 2.9 mmHg (range 19.0~30.0 mmHg) as measured by manometry and 23.4 ± 3.2 mmHg (range 18.6~28.4 mmHg) according to tonometry. In cattle, IOP was found to be 19.7 ± 1.2 mmHg (range 18.0~22.0 mmHg) by manometry and 18.8 ± 1.7 mmHg (range 15.9~20.8 mmHg) by tonometry. There was a strong correlation between the IOP values obtained by direct ocular manometry and the tonometer in both horses and cattle. Our results demonstrate that the Perkins handheld tonometer could be an additional tool for accurately measuring IOP in equine and bovine eyes.

Entities:  

Mesh:

Year:  2011        PMID: 21586877      PMCID: PMC3104172          DOI: 10.4142/jvs.2011.12.2.171

Source DB:  PubMed          Journal:  J Vet Sci        ISSN: 1229-845X            Impact factor:   1.672


  18 in total

1.  Tono-Pen XL calibration curves for cats, cows and sheep.

Authors:  Christopher L Passaglia; Xiaoli Guo; Jie Chen; John B Troy
Journal:  Vet Ophthalmol       Date:  2004 Jul-Aug       Impact factor: 1.644

2.  Comparison of simultaneous readings of intraocular pressure in rabbits using Perkins handheld, Tono-Pen XL, and TonoVet tonometers.

Authors:  Giedrius Kalesnykas; Hannu Uusitalo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-11-21       Impact factor: 3.117

3.  Evaluation of the Perkins handheld applanation tonometer in the measurement of intraocular pressure in dogs and cats.

Authors:  Silvia Franco Andrade; Tatiana Cremonezi; Cristiane Aparecida Miranda Zachi; Caroline Ferreira Lonchiati; Juliana Dalarrosa Amatuzzi; Keila Priscilla Sakamoto; Paulo Augusto de Arruda Mello
Journal:  Vet Ophthalmol       Date:  2009 Sep-Oct       Impact factor: 1.644

4.  Evaluation of applanation tonometers for the dog eye.

Authors:  K N Gelatt; R L Peiffer; G G Gum; R M Gwin; J L Erickson
Journal:  Invest Ophthalmol Vis Sci       Date:  1977-10       Impact factor: 4.799

Review 5.  Cyanoacrylate glue for corneal perforations: a description of a surgical technique and a review of the literature.

Authors:  B J Vote; M J Elder
Journal:  Clin Exp Ophthalmol       Date:  2000-12       Impact factor: 4.207

6.  Calibration of the Alcon applanation pneumatonograph and Perkins tonometer for use in rabbits and cats.

Authors:  B R Hammond; P Bhattacherjee
Journal:  Curr Eye Res       Date:  1984-09       Impact factor: 2.424

7.  Intraocular pressure in normal dairy cattle.

Authors:  G.G. Gum; K.N. Gelatt; D.N. Miller; E.O. MacKay
Journal:  Vet Ophthalmol       Date:  1998       Impact factor: 1.644

8.  Comparison of the rebound tonometer (ICare) to the applanation tonometer (Tonopen XL) in normotensive dogs.

Authors:  M Leiva; C Naranjo; M T Peña
Journal:  Vet Ophthalmol       Date:  2006 Jan-Feb       Impact factor: 1.644

9.  Effect of auriculopalpebral nerve block and intravenous administration of xylazine on intraocular pressure and corneal thickness in horses.

Authors:  A van der Woerdt; B C Gilger; D A Wilkie; S M Strauch
Journal:  Am J Vet Res       Date:  1995-02       Impact factor: 1.156

10.  Steroid-induced ocular hypertension in normal cattle.

Authors:  Rosana Gerometta; Steven M Podos; Oscar A Candia; Brian Wu; Luis A Malgor; Thomas Mittag; John Danias
Journal:  Arch Ophthalmol       Date:  2004-10
View more
  3 in total

1.  Intraocular pressure measurements in cattle, sheep, and goats with 2 different types of tonometers.

Authors:  Nina Peche; Johanna Corinna Eule
Journal:  Can J Vet Res       Date:  2018-07       Impact factor: 1.310

2.  Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods.

Authors:  R Arora; H Bellamy; Mw Austin
Journal:  Clin Ophthalmol       Date:  2014-03-26

3.  Allometry and Scaling of the Intraocular Pressure and Aqueous Humour Flow Rate in Vertebrate Eyes.

Authors:  Moussa A Zouache; Ian Eames; Amir Samsudin
Journal:  PLoS One       Date:  2016-03-18       Impact factor: 3.240

  3 in total