Literature DB >> 21505855

Computed tomography in patients with cardiac pacemakers: difficulties and solutions.

Rafal Mlynarski1, Maciej Sosnowski, Agnieszka Mlynarska, Michał Tendera.   

Abstract

The presence of cardiac pacemaker systems may significantly limit interpretation of multi-slice computed tomography (MSCT) images. In 80 patients (45 men; aged 69.5 ± 13.4) with previously implanted anti-arrhythmic devices, a 64-slice CT (Aquilion-64) was performed. In 61 patients (76.3%), ECG gating was used (coronaries visualization) and in 19 patients (23.7%) without ECG gating (not coronaries visualization). In all 19 patients without ECG gating MSCT images were diagnostic. In 37 (60.6%) patients of 61, there was no problem with gating process and image quality was diagnostic. In 24 (39.4%) with visible spikes in the ECG-gating group, there were difficulties in differentiating the R spike from an artificial spike (unipolar pacing) by MSCT software. In 15 patients (24.6%) after reprogramming, it was possible to obtain good quality images. In nine (14.7%) patients, it was not possible to reprogram devices due to old unipolar leads, but in two cases (3.3%), ECG gating was corrected manually and good image quality was obtained. In seven (11.5%) patients, it was not possible to perform ECG gating. The ECG gating process was identified as the main cause of the imaging problems. Bipolar leads working as bipolar pacing seem to be necessary to perform MSCT with ECG gating. A unipolar system lead may cause serious problems with reconstructions.

Entities:  

Mesh:

Year:  2011        PMID: 21505855     DOI: 10.1007/s00380-011-0140-6

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  14 in total

1.  Cardiac pacemakers and implantable cardioverter defibrillators: in vitro magnetic resonance imaging evaluation at 1.5-tesla.

Authors:  Frank G Shellock; Laura Fischer; David S Fieno
Journal:  J Cardiovasc Magn Reson       Date:  2007       Impact factor: 5.364

Review 2.  ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology.

Authors:  Robert C Hendel; Manesh R Patel; Christopher M Kramer; Michael Poon; Robert C Hendel; James C Carr; Nancy A Gerstad; Linda D Gillam; John McB Hodgson; Raymond J Kim; Christopher M Kramer; John R Lesser; Edward T Martin; Joseph V Messer; Rita F Redberg; Geoffrey D Rubin; John S Rumsfeld; Allen J Taylor; Wm Guy Weigold; Pamela K Woodard; Ralph G Brindis; Robert C Hendel; Pamela S Douglas; Eric D Peterson; Michael J Wolk; Joseph M Allen; Manesh R Patel
Journal:  J Am Coll Cardiol       Date:  2006-10-03       Impact factor: 24.094

3.  Does high-power computed tomography scanning equipment affect the operation of pacemakers?

Authors:  Satoshi Yamaji; Shinobu Imai; Fumio Saito; Hiroshi Yagi; Toshio Kushiro; Takahisa Uchiyama
Journal:  Circ J       Date:  2006-02       Impact factor: 2.993

4.  Effects of CT irradiation on implantable cardiac rhythm management devices.

Authors:  Cynthia H McCollough; Jie Zhang; Andrew N Primak; Wesley J Clement; John R Buysman
Journal:  Radiology       Date:  2007-04-26       Impact factor: 11.105

5.  Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association.

Authors:  Panos E Vardas; Angelo Auricchio; Jean-Jacques Blanc; Jean-Claude Daubert; Helmut Drexler; Hugo Ector; Maurizio Gasparini; Cecilia Linde; Francisco Bello Morgado; Ali Oto; Richard Sutton; Maria Trusz-Gluza
Journal:  Eur Heart J       Date:  2007-08-28       Impact factor: 29.983

6.  Influence of DDD rate response pacing with integrated double sensors on physical efficiency and quality of life.

Authors:  Eugeniusz Pilat; Rafal Mlynarski; Agnieszka Wlodyka; Wlodzimierz Kargul
Journal:  Europace       Date:  2008-08-18       Impact factor: 5.214

7.  The presence of endocardial leads may limit applicability of coronary CT angiography.

Authors:  Maciej Sosnowski; Rafal Mlynarski; Agnieszka Wlodyka; Jan Brzoska; Wlodzimierz Kargul; Michal Tendera
Journal:  Scand Cardiovasc J       Date:  2010-02       Impact factor: 1.589

8.  Coronary sinus ostium: the key structure in the heart's anatomy from the electrophysiologist's point of view.

Authors:  Rafal Mlynarski; Agnieszka Mlynarska; Michal Tendera; Maciej Sosnowski
Journal:  Heart Vessels       Date:  2011-01-15       Impact factor: 2.037

9.  Prevalence and characterization of asymptomatic pacemaker and ICD lead perforation on CT.

Authors:  David A Hirschl; Vineet R Jain; Hugo Spindola-Franco; Jay N Gross; Linda B Haramati
Journal:  Pacing Clin Electrophysiol       Date:  2007-01       Impact factor: 1.976

10.  No severe pulmonary vein stenosis after extensive encircling pulmonary vein isolation: 12-month follow-up with 3D computed tomography.

Authors:  Shingo Maeda; Yoshito Iesaka; Kiyoshi Otomo; Kikuya Uno; Yasutoshi Nagata; Kenji Suzuki; Hitoshi Hachiya; Masahiko Goya; Atsushi Takahashi; Hideomi Fujiwara; Mitsuaki Isobe
Journal:  Heart Vessels       Date:  2010-12-04       Impact factor: 2.037

View more
  6 in total

1.  Unusual "ratchet syndrome": spontaneous lead retraction after a generator exchange.

Authors:  Koichiro Ejima; Morio Shoda; Bun Yashiro; Kentaro Yoshida; Toshiaki Nuki; Ken Kato; Tetsuyuki Manaka; Nobuhisa Hagiwara
Journal:  Heart Vessels       Date:  2013-07-12       Impact factor: 2.037

2.  Cardiac CT: Imaging of and Through Cardiac Devices.

Authors:  Gary S Mak; Quynh A Truong
Journal:  Curr Cardiovasc Imaging Rep       Date:  2012-10-01

Review 3.  [Coronary computed tomography and cardiac devices : Diagnostic results or nothing but artifacts?]

Authors:  Silvia Smolka; Stephan Achenbach
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2022-07-05

4.  Successful dual chamber ICD implantation via a persistent left superior vena cava after ratchet syndrome.

Authors:  Naofumi Anjo; Shiro Nakahara; Tohru Kamijima; Yuichi Hori; Ayako Nakagawa; Naoki Nishiyama; Kouta Yamada; Takaaki Komatsu; Sayuki Kobayashi; Yoshihiko Sakai; Isao Taguchi
Journal:  J Arrhythm       Date:  2016-02-06

5.  Deformable Known Component Model-Based Reconstruction for Coronary CT Angiography.

Authors:  X Zhang; S Tilley; S Xu; A Mathews; E R McVeigh; J W Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

6.  Two-point left ventricle pacing and cardiac computed tomography.

Authors:  Rafal Mlynarski; Agnieszka Mlynarska; Eugeniusz Pilat; Rafal Gardas; Jacek Wilczek; Maciej Sosnowski
Journal:  Case Rep Cardiol       Date:  2012-09-09
  6 in total