Literature DB >> 23626865

Cardiac CT: Imaging of and Through Cardiac Devices.

Gary S Mak1, Quynh A Truong.   

Abstract

For patients with cardiac devices, cardiac computed tomography (CT) remains the mainstay for imaging due to its superior resolution as compared with echocardiography and nuclear studies and no contraindication to metal as with cardiac magnetic resonance imaging. This review focuses on the evaluation and pitfalls of coronary arterial imaging in patients with devices, such as pacemakers, implantable defibrillators, cardiac resynchronization therapy (CRT), as well as complications such as lead perforation and safety concerns of CT interference. We discuss both pre- and post-procedural CRT assessment for coronary venous imaging and pre-procedural myocardial scar assessment to localize regions of scar and peri-infarct zone to facilitate ventricular tachycardia ablation in patients with devices. We describe potential new research on dyssynchrony and integration with myocardial scar and site of latest activation for patients with or being considered for CRT. We detail the utility of CT for the assessment of proper function and complications in patients with left ventricular assist device implantation.

Entities:  

Keywords:  Cardiac CT; Cardiac resynchronization therapy; Defibrillator; Left Ventricular assist device; Pacemaker

Year:  2012        PMID: 23626865      PMCID: PMC3636997          DOI: 10.1007/s12410-012-9150-8

Source DB:  PubMed          Journal:  Curr Cardiovasc Imaging Rep        ISSN: 1941-9074


  49 in total

1.  Influence of high-energy photon beam irradiation on pacemaker operation.

Authors:  J Mouton; R Haug; A Bridier; B Dodinot; F Eschwege
Journal:  Phys Med Biol       Date:  2002-08-21       Impact factor: 3.609

2.  Imaging of the cardiac venous system: comparison of MDCT and conventional angiography.

Authors:  Georg Mühlenbruch; Ralf Koos; Joachim E Wildberger; Rolf W Günther; Andreas H Mahnken
Journal:  AJR Am J Roentgenol       Date:  2005-11       Impact factor: 3.959

3.  Noninvasive evaluation of cardiac veins with 16-MDCT angiography.

Authors:  Suhny Abbara; Ricardo C Cury; Koen Nieman; Vivek Reddy; Fabian Moselewski; Steven Schmidt; Maros Ferencik; Udo Hoffmann; Thomas J Brady; Stephan Achenbach
Journal:  AJR Am J Roentgenol       Date:  2005-10       Impact factor: 3.959

4.  Registration of three-dimensional left atrial computed tomographic images with projection images obtained using fluoroscopy.

Authors:  Jasbir Sra; David Krum; Angela Malloy; Melissa Vass; Barry Belanger; Elisabeth Soubelet; Regis Vaillant; Masood Akhtar
Journal:  Circulation       Date:  2005-12-13       Impact factor: 29.690

5.  Does high-power computed tomography scanning equipment affect the operation of pacemakers?

Authors:  Satoshi Yamaji; Shinobu Imai; Fumio Saito; Hiroshi Yagi; Toshio Kushiro; Takahisa Uchiyama
Journal:  Circ J       Date:  2006-02       Impact factor: 2.993

6.  Effects of CT irradiation on implantable cardiac rhythm management devices.

Authors:  Cynthia H McCollough; Jie Zhang; Andrew N Primak; Wesley J Clement; John R Buysman
Journal:  Radiology       Date:  2007-04-26       Impact factor: 11.105

Review 7.  The role of echocardiography and other imaging modalities in patients with left ventricular assist devices.

Authors:  Jerry D Estep; Raymond F Stainback; Stephen H Little; Guillermo Torre; William A Zoghbi
Journal:  JACC Cardiovasc Imaging       Date:  2010-10

8.  Role of multislice computed tomography for preprocedural evaluation before revision of a chronically implanted transvenous left ventricular lead.

Authors:  Angelo Auricchio; Antonio Sorgente; Jagmeet P Singh; Francesco Faletra; Cristina Conca; Giovanni B Pedrazzini; Elena Pasotti; Francesco Siclari; Tiziano Moccetti
Journal:  Am J Cardiol       Date:  2007-11-15       Impact factor: 2.778

Review 9.  Current status of cardiac transplantation and mechanical circulatory support.

Authors:  Andrew Boyle
Journal:  Curr Heart Fail Rep       Date:  2009-03

10.  Imaging of the coronary venous system in patients with congestive heart failure: comparison of 16 slice MSCT and retrograde coronary sinus venography: comparative imaging of coronary venous system.

Authors:  Christian Knackstedt; Georg Mühlenbruch; Karl Mischke; Thomas Schimpf; Elmar Spüntrup; Rolf W Günther; Beyhan Sanli; Malte Kelm; Patrick Schauerte; Andreas H Mahnken
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-09       Impact factor: 2.357

View more
  11 in total

1.  Diagnosis and Management of LVAD Thrombosis.

Authors:  Edo Y Birati; J Eduardo Rame
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-02

2.  Cardiac resynchronization therapy update: evolving indications, expanding benefit?

Authors:  C Butcher; Y Mareev; V Markides; M Mason; T Wong; J G F Cleland
Journal:  Curr Cardiol Rep       Date:  2015-10       Impact factor: 2.931

3.  Coronary CT angiography in patients with implanted cardiac devices: initial experience with the metal artefact reduction technique.

Authors:  Fuminari Tatsugami; Toru Higaki; Hiroaki Sakane; Wataru Fukumoto; Makoto Iida; Yasutaka Baba; Chikako Fujioka; Yasuki Kihara; So Tsushima; Kazuo Awai
Journal:  Br J Radiol       Date:  2016-09-29       Impact factor: 3.039

4.  Cardiac conduction devices in the radiologic comparative identification of decedents.

Authors:  Vasiliki Chatzaraki; Garyfalia Ampanozi; Michael J Thali; Wolf Schweitzer
Journal:  Forensic Sci Med Pathol       Date:  2019-11-14       Impact factor: 2.007

Review 5.  [Coronary computed tomography and cardiac devices : Diagnostic results or nothing but artifacts?]

Authors:  Silvia Smolka; Stephan Achenbach
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2022-07-05

6.  Transendocardial mesenchymal stem cells and mononuclear bone marrow cells for ischemic cardiomyopathy: the TAC-HFT randomized trial.

Authors:  Alan W Heldman; Darcy L DiFede; Joel E Fishman; Juan P Zambrano; Barry H Trachtenberg; Vasileios Karantalis; Muzammil Mushtaq; Adam R Williams; Viky Y Suncion; Ian K McNiece; Eduard Ghersin; Victor Soto; Gustavo Lopera; Roberto Miki; Howard Willens; Robert Hendel; Raul Mitrani; Pradip Pattany; Gary Feigenbaum; Behzad Oskouei; John Byrnes; Maureen H Lowery; Julio Sierra; Mariesty V Pujol; Cindy Delgado; Phillip J Gonzalez; Jose E Rodriguez; Luiza Lima Bagno; Didier Rouy; Peter Altman; Cheryl Wong Po Foo; Jose da Silva; Erica Anderson; Richard Schwarz; Adam Mendizabal; Joshua M Hare
Journal:  JAMA       Date:  2014-01-01       Impact factor: 56.272

7.  Comprehensive use of cardiac computed tomography to guide left ventricular lead placement in cardiac resynchronization therapy.

Authors:  Jonathan M Behar; Ronak Rajani; Amir Pourmorteza; Rebecca Preston; Orod Razeghi; Steve Niederer; Shaumik Adhya; Simon Claridge; Tom Jackson; Ben Sieniewicz; Justin Gould; Gerry Carr-White; Reza Razavi; Elliot McVeigh; Christopher Aldo Rinaldi
Journal:  Heart Rhythm       Date:  2017-05-04       Impact factor: 6.343

8.  Comparison of Echocardiography and 64-Multislice Spiral Computed Tomography for the Diagnosis of Pediatric Congenital Heart Disease.

Authors:  Aiyin Li; Zhenpeng Peng; Chengqi Zhang
Journal:  Med Sci Monit       Date:  2017-05-13

9.  Reduction of CT artifacts from cardiac implantable electronic devices using a combination of virtual monoenergetic images and post-processing algorithms.

Authors:  Lenhard Pennig; David Zopfs; Roman Gertz; Johannes Bremm; Charlotte Zaeske; Nils Große Hokamp; Erkan Celik; Lukas Goertz; Marcel Langenbach; Thorsten Persigehl; Amit Gupta; Jan Borggrefe; Simon Lennartz; Kai Roman Laukamp
Journal:  Eur Radiol       Date:  2021-02-25       Impact factor: 5.315

10.  An unusual course of a pacemaker lead in congenitally corrected transposition of the great arteries.

Authors:  Karthik Viswanathan; Nicholas Jackson; Bernd J Wintersperger; Krishnakumar Nair
Journal:  Indian Pacing Electrophysiol J       Date:  2015-07-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.