Literature DB >> 21500263

Quantitative magnetization transfer ultrashort echo time imaging of the Achilles tendon.

Richard J Hodgson1, Robert Evans, Peter Wright, Andrew J Grainger, Philip J O'Connor, Philip Helliwell, Dennis McGonagle, Paul Emery, Matthew D Robson.   

Abstract

Ultrashort echo time imaging allows the short T(2) Achilles tendon to be directly visualized with MRI. Radiofrequency saturation 1 kHz or less off-resonance has been used previously to improve image contrast. In this study, magnetization transfer was investigated in the Achilles tendon of eight normal volunteers and one patient with psoriatic arthritis. 2D Ultrashort echo time images were acquired using saturation pulses 2-100 kHz off-resonance at 4 pulse powers. On-resonance saturation recovery images were also obtained to estimate T(1). The results were fitted to a two compartment quantitative magnetization transfer model. The estimated bound proton fraction for the eight healthy volunteers was 21.0 ± 1.2% (mean ± standard deviation) compared to 16.4% in the patient with psoriatic arthritis (P < 0.05). The T(2) of the bound protons was measured as 6.1 ± 0.3 μsec in the healthy volunteers and 6.0 μsec in the patient. This technique appears clinically feasible and may be useful for assessing the collagen and water changes which occur in Achilles tendinopathy.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21500263     DOI: 10.1002/mrm.22715

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Quantitative two-dimensional ultrashort echo time magnetization transfer (2D UTE-MT) imaging of cortical bone.

Authors:  Ya-Jun Ma; Anthony Tadros; Jiang Du; Eric Y Chang
Journal:  Magn Reson Med       Date:  2017-08-03       Impact factor: 4.668

2.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

3.  Magnetization transfer imaging of cortical bone in vivo using a zero echo time sequence in mice at 4.7 T: a feasibility study.

Authors:  Magda Marcon; Markus Weiger; Daniel Keller; Moritz C Wurnig; Christian Eberhardt; Daniel Eberli; Andreas Boss
Journal:  MAGMA       Date:  2016-07-06       Impact factor: 2.310

4.  Depiction of achilles tendon microstructure in vivo using high-resolution 3-dimensional ultrashort echo-time magnetic resonance imaging at 7 T.

Authors:  Misung Han; Peder E Z Larson; Jing Liu; Roland Krug
Journal:  Invest Radiol       Date:  2014-05       Impact factor: 6.016

5.  Resolving estimation uncertainties of chemical shift encoded fat-water imaging using magnetization transfer effect.

Authors:  Alexey Samsonov; Fang Liu; Julia V Velikina
Journal:  Magn Reson Med       Date:  2019-03-07       Impact factor: 4.668

6.  Quantitative magnetization transfer ultrashort echo time imaging using a time-efficient 3D multispoke Cones sequence.

Authors:  Ya-Jun Ma; Eric Y Chang; Michael Carl; Jiang Du
Journal:  Magn Reson Med       Date:  2017-05-03       Impact factor: 4.668

7.  Advanced MR methods at ultra-high field (7 Tesla) for clinical musculoskeletal applications.

Authors:  Siegfried Trattnig; Stefan Zbýň; Benjamin Schmitt; Klaus Friedrich; Vladimir Juras; Pavol Szomolanyi; Wolfgang Bogner
Journal:  Eur Radiol       Date:  2012-06-12       Impact factor: 5.315

8.  Rotator cuff tendon assessment using magic-angle insensitive 3D ultrashort echo time cones magnetization transfer (UTE-Cones-MT) imaging and modeling with histological correlation.

Authors:  Yanchun Zhu; Xin Cheng; Yajun Ma; Jonathan H Wong; Yaoqin Xie; Jiang Du; Eric Y Chang
Journal:  J Magn Reson Imaging       Date:  2017-12-08       Impact factor: 4.813

9.  UTE bi-component analysis of T2* relaxation in articular cartilage.

Authors:  H Shao; E Y Chang; C Pauli; S Zanganeh; W Bae; C B Chung; G Tang; J Du
Journal:  Osteoarthritis Cartilage       Date:  2015-09-14       Impact factor: 6.576

10.  3D UTE bicomponent imaging of cortical bone using a soft-hard composite pulse for excitation.

Authors:  Liang Li; Yanjun Chen; Zhao Wei; Zhenyu Cai; Saeed Jerban; Yunfei Zha; Ya-Jun Ma
Journal:  Magn Reson Med       Date:  2020-09-29       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.