3D UTE bicomponent imaging of cortical bone using a soft-hard composite pulse for excitation.

Liang Li1,2, Yanjun Chen2,3, Zhao Wei2, Zhenyu Cai2, Saeed Jerban2, Yunfei Zha1, Ya-Jun Ma2.   

Abstract

PURPOSE: To evaluate 3D UTE bicomponent imaging of cortical bone ex vivo and in vivo using a newly designed soft-hard composite pulse for excitation.
METHODS: Chemical shift artifacts, presenting as fat-water oscillation or combination-induced signal oscillation, significantly reduce the accuracy of quantitative UTE bicomponent analysis of cortical bone. To achieve fat suppression for more reliable bicomponent analysis, a newly developed soft-hard excitation pulse was used with UTE imaging and compared with a single rectangular pulse excitation without and with a conventional fat saturation (FatSat) module. These 3 sequences were applied to 8 bovine bone samples without marrow fat, 3 bovine bone samples with marrow fat, and tibial midshafts of 5 healthy human volunteers. Bicomponent analyses were performed in both ex vivo and in vivo studies.
RESULTS: The soft-hard pulse provided comparable fat suppression, but much reduced bone signal attenuation compared with the FatSat module. Better bicomponent T 2 ∗ fitting was also achieved with the soft-hard excitation pulse because it greatly reduced chemical shift artifacts and outperformed the single rectangular pulse without or with FatSat. Although the FatSat module reduced fat signals and related fat-water oscillation, the water signals were significantly attenuated with more than 40% reduction due to direction saturation. For the inner layer of tibial midshaft in healthy volunteers, fitting errors increased from 3.78% for the soft-hard pulse to 11.43% and 5.16%, respectively, for the single rectangular pulse without and with the FatSat module.
CONCLUSION: The 3D UTE sequence with a new soft-hard excitation pulse allows more reliable bicomponent imaging of cortical bone.
© 2020 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  cortical bone; fat suppression; soft-hard composite pulse; ultrashort TE

Mesh:

Year:  2020        PMID: 32989787      PMCID: PMC7924727          DOI: 10.1002/mrm.28528

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

1.  Effects of fat saturation on short T2 quantification.

Authors:  Michael Carl; Amin Nazaran; Graeme M Bydder; Jiang Du
Journal:  Magn Reson Imaging       Date:  2017-06-16       Impact factor: 2.546

2.  Fast volumetric imaging of bound and pore water in cortical bone using three-dimensional ultrashort-TE (UTE) and inversion recovery UTE sequences.

Authors:  Jun Chen; Michael Carl; Yajun Ma; Hongda Shao; Xing Lu; Bimin Chen; Eric Y Chang; Zhihong Wu; Jiang Du
Journal:  NMR Biomed       Date:  2016-08-05       Impact factor: 4.044

Review 3.  Sarcopenic obesity in older adults: aetiology, epidemiology and treatment strategies.

Authors:  John A Batsis; Dennis T Villareal
Journal:  Nat Rev Endocrinol       Date:  2018-09       Impact factor: 43.330

4.  Yet more evidence that myelin protons can be directly imaged with UTE sequences on a clinical 3T scanner: Bicomponent T2* analysis of native and deuterated ovine brain specimens.

Authors:  Shu-Juan Fan; Yajun Ma; Yanchun Zhu; Adam Searleman; Nikolaus M Szeverenyi; Graeme M Bydder; Jiang Du
Journal:  Magn Reson Med       Date:  2017-12-21       Impact factor: 4.668

Review 5.  Magnetic resonance of calcified tissues.

Authors:  Felix W Wehrli
Journal:  J Magn Reson       Date:  2013-01-10       Impact factor: 2.229

6.  k-space water-fat decomposition with T2* estimation and multifrequency fat spectrum modeling for ultrashort echo time imaging.

Authors:  Kang Wang; Huanzhou Yu; Jean H Brittain; Scott B Reeder; Jiang Du
Journal:  J Magn Reson Imaging       Date:  2010-04       Impact factor: 4.813

7.  Ultrashort echo time magnetic resonance imaging (UTE-MRI) of cortical bone correlates well with histomorphometric assessment of bone microstructure.

Authors:  Saeed Jerban; Yajun Ma; Jonathan H Wong; Amin Nazaran; Adam Searleman; Lidi Wan; Judith Williams; Jiang Du; Eric Y Chang
Journal:  Bone       Date:  2019-03-12       Impact factor: 4.398

8.  Fat suppression for ultrashort echo time imaging using a novel soft-hard composite radiofrequency pulse.

Authors:  Ya-Jun Ma; Saeed Jerban; Hyungseok Jang; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2019-07-17       Impact factor: 4.668

9.  Ultrashort echo time (UTE) imaging with bi-component analysis: bound and free water evaluation of bovine cortical bone subject to sequential drying.

Authors:  Reni Biswas; Won Bae; Eric Diaz; Koichi Masuda; Christine B Chung; Graeme M Bydder; Jiang Du
Journal:  Bone       Date:  2011-12-10       Impact factor: 4.398

Review 10.  Qualitative and quantitative ultrashort-TE MRI of cortical bone.

Authors:  Jiang Du; Graeme M Bydder
Journal:  NMR Biomed       Date:  2012-12-28       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.