Literature DB >> 21495065

The capsule's contribution to total hip construct stability--a finite element analysis.

Jacob M Elkins1, Nicholas J Stroud, M James Rudert, Yuki Tochigi, Douglas R Pedersen, Benjamin J Ellis, John J Callaghan, Jeffrey A Weiss, Thomas D Brown.   

Abstract

Instability is a significant concern in total hip arthroplasty (THA), particularly when there is structural compromise of the capsule due to pre-existing pathology or due to necessities of surgical approach. An experimentally grounded fiber-direction-based finite element model of the hip capsule was developed, and was integrated with an established three-dimensional model of impingement/dislocation. Model validity was established by close similarity to results from a cadaveric experiment in a servohydraulic hip simulator. Parametric computational runs explored effects of graded levels of capsule thickness, of regional detachment from the capsule's femoral or acetabular insertions, of surgical incisions of capsule substance, and of capsule defect repairs. Depending strongly upon the specific site, localized capsule defects caused varying degrees of construct stability compromise, with several specific situations involving over 60% decrement in dislocation resistance. Construct stability was returned substantially toward intact-capsule levels following well-conceived repairs, although the suture sites involved were often at substantial risk of failure. These parametric model results underscore the importance of retaining or robustly repairing capsular structures in THA, in order to maximize overall construct stability.
Copyright © 2011 Orthopaedic Research Society.

Entities:  

Mesh:

Year:  2011        PMID: 21495065      PMCID: PMC3160501          DOI: 10.1002/jor.21435

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  29 in total

1.  The anatomy and function of the gluteus minimus muscle.

Authors:  M Beck; J B Sledge; E Gautier; C F Dora; R Ganz
Journal:  J Bone Joint Surg Br       Date:  2000-04

2.  Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation.

Authors:  Mark E Nadzadi; Douglas R Pedersen; H John Yack; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2003-04       Impact factor: 2.712

3.  Piriformis tendon repair failure after total hip replacement.

Authors:  J T Kao; S T Woolson
Journal:  Orthop Rev       Date:  1992-02

4.  Hip mechanics after posterior structure repair in total hip arthroplasty.

Authors:  William M Mihalko; Leo A Whiteside
Journal:  Clin Orthop Relat Res       Date:  2004-03       Impact factor: 4.176

5.  Activity-dependence of the "safe zone" for impingement versus dislocation avoidance.

Authors:  D R Pedersen; J J Callaghan; T D Brown
Journal:  Med Eng Phys       Date:  2004-11-23       Impact factor: 2.242

Review 6.  Instability after total hip arthroplasty.

Authors:  B F Morrey
Journal:  Orthop Clin North Am       Date:  1992-04       Impact factor: 2.472

7.  Design factors influencing performance of constrained acetabular liners: finite element characterization.

Authors:  Suzanne M Bouchard; Kristofer J Stewart; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2006       Impact factor: 2.712

8.  A clinical comparison of the anterolateral and posterolateral approaches to the hip.

Authors:  M A Ritter; L D Harty; M E Keating; P M Faris; J B Meding
Journal:  Clin Orthop Relat Res       Date:  2001-04       Impact factor: 4.176

9.  Normal processes and restraints in wound healing.

Authors:  N H Carpenter; D J Gates; H T Williams
Journal:  Can J Surg       Date:  1977-07       Impact factor: 2.089

10.  Dislocation in low-friction arthroplasty.

Authors:  E García-Cimbrelo; L Munuera
Journal:  J Arthroplasty       Date:  1992-06       Impact factor: 4.757

View more
  28 in total

1.  Effect of ACL reconstruction graft size on simulated Lachman testing: a finite element analysis.

Authors:  Robert W Westermann; Brian R Wolf; Jacob M Elkins
Journal:  Iowa Orthop J       Date:  2013

2.  The morphology of the mouse masticatory musculature.

Authors:  Hester Baverstock; Nathan S Jeffery; Samuel N Cobb
Journal:  J Anat       Date:  2013-05-20       Impact factor: 2.610

3.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

Review 4.  Computational techniques for the assessment of fracture repair.

Authors:  Donald D Anderson; Thaddeus P Thomas; Ana Campos Marin; Jacob M Elkins; William D Lack; Damien Lacroix
Journal:  Injury       Date:  2014-06       Impact factor: 2.586

5.  Edge-loading severity as a function of cup lip radius in metal-on-metal total hips--a finite element analysis.

Authors:  Jacob M Elkins; Karen M Kruger; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Orthop Res       Date:  2011-08-02       Impact factor: 3.494

6.  Arthroscopic Technique of Capsular Plication for the Treatment of Hip Instability.

Authors:  Sivashankar Chandrasekaran; S Pavan Vemula; Timothy J Martin; Carlos Suarez-Ahedo; Parth Lodhia; Benjamin G Domb
Journal:  Arthrosc Tech       Date:  2015-04-13

Review 7.  Impingement and dislocation in total hip arthroplasty: mechanisms and consequences.

Authors:  Thomas D Brown; Jacob M Elkins; Douglas R Pedersen; John J Callaghan
Journal:  Iowa Orthop J       Date:  2014

8.  Capsular Preservation Using Suture Suspension Technique in Hip Arthroscopy for Femoroacetabular Impingement.

Authors:  Andrea M Spiker; Christopher L Camp; Brian T Barlow; Shawn G Anthony; Struan H Coleman
Journal:  Arthrosc Tech       Date:  2016-08-15

9.  Bone-on-bone versus hardware impingement in total hips: a biomechanical study.

Authors:  Jacob M Elkins; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2012

10.  Morbid obesity may increase dislocation in total hip patients: a biomechanical analysis.

Authors:  Jacob M Elkins; Matej Daniel; Douglas R Pedersen; Bhupinder Singh; H John Yack; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2012-08-21       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.