Literature DB >> 15823473

Activity-dependence of the "safe zone" for impingement versus dislocation avoidance.

D R Pedersen1, J J Callaghan, T D Brown.   

Abstract

Presently, the basis for optimal cup positioning to minimize the likelihood of dislocation rests upon subjective clinical impressions. To help elucidate optimal cup positioning more objectively, and to clarify the distinction between impingement avoidance and dislocation avoidance, kinematic and kinetic inputs for seven dislocation-prone activities were applied to finite element models of a contemporary 22-mm modular total hip reconstruction. Twenty-five cup placement positions (combinations of 30, 40, 50, 60, and 70 degrees of abduction with 0, 10, 20, 30, and 40 degrees of anteversion) were chosen to include the conventional 'safe zone' of 30-50 degrees of tilt and 5-25 degrees of anteversion. Activities studied were: rising from a low seat (toilet) and from a normal height chair, leg-crossing while seated, tying a shoe from a seated position, bending at the hip from an erect stance to retrieve an object on the floor (stooping), a standing pivot maneuver, and rolling over in bed. Neck-on-cup impingement occurred during one or more of the dislocation-prone activities at all 25 cup positions. Of the 175 combinations of cup position and kinetic challenge, dislocation and impingement events both occurred for 51 situations, while impingement occurred in 45 instances without dislocation, and dislocation occurred in 10 instances without impingement. Neither dislocation nor impingement was observed in the 69 other combinations of cup position and loading challenge. Kappa statistics showed dislocation and impingement, as outcome measures of activity-dependent challenges, exhibit little more than chance agreement. Therefore, the use of impingement range of motion (ROM) as a predictor of a given cup position's vulnerability to dislocation should be viewed cautiously.

Mesh:

Year:  2004        PMID: 15823473     DOI: 10.1016/j.medengphy.2004.09.004

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  19 in total

1.  Hard-on-hard total hip impingement causes extreme contact stress concentrations.

Authors:  Jacob M Elkins; Megan K O'Brien; Nicholas J Stroud; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

2.  [Treatment of acetabular defects with the trabecular metal revision system].

Authors:  G I Wassilew; V Janz; C Perka; M Müller
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

3.  MyHip: supporting planning and surgical guidance for a better total hip arthroplasty : A pilot study.

Authors:  Jérôme Schmid; Christophe Chênes; Sylvain Chagué; Pierre Hoffmeyer; Panayiotis Christofilopoulos; Massimiliano Bernardoni; Caecilia Charbonnier
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-01       Impact factor: 2.924

4.  The capsule's contribution to total hip construct stability--a finite element analysis.

Authors:  Jacob M Elkins; Nicholas J Stroud; M James Rudert; Yuki Tochigi; Douglas R Pedersen; Benjamin J Ellis; John J Callaghan; Jeffrey A Weiss; Thomas D Brown
Journal:  J Orthop Res       Date:  2011-04-14       Impact factor: 3.494

5.  Edge-loading severity as a function of cup lip radius in metal-on-metal total hips--a finite element analysis.

Authors:  Jacob M Elkins; Karen M Kruger; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Orthop Res       Date:  2011-08-02       Impact factor: 3.494

Review 6.  [Navigation in hip joint revision endoprosthetics].

Authors:  P A Grützner
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

Review 7.  Impingement and dislocation in total hip arthroplasty: mechanisms and consequences.

Authors:  Thomas D Brown; Jacob M Elkins; Douglas R Pedersen; John J Callaghan
Journal:  Iowa Orthop J       Date:  2014

8.  Impingement in Total Hip Replacement: Mechanisms and Consequences.

Authors:  Thomas D Brown; John J Callaghan
Journal:  Curr Orthop       Date:  2008-12-01

9.  Risk of impingement and third-body abrasion with 28-mm metal-on-metal bearings.

Authors:  Ian C Clarke; Jean-Yves Lazennec; Adrien Brusson; Christina Savisaar; John G Bowsher; Michelle Burgett; Thomas K Donaldson
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

Review 10.  Navigated cup implantation in hip arthroplasty.

Authors:  Johannes Beckmann; Dirk Stengel; Markus Tingart; Jürgen Götz; Joachim Grifka; Christian Lüring
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.