Literature DB >> 24431733

Comparative Evaluation of Marginal and Internal Gap of Co-Cr Copings Fabricated from Conventional Wax Pattern, 3D Printed Resin Pattern and DMLS Tech: An In Vitro Study.

Eswaran Bhaskaran1, N S Azhagarasan2, Saket Miglani2, T Ilango3, G Phani Krishna3, B Gajapathi4.   

Abstract

Accuracy of the fit of the restoration has always remained as one of the primary factors in determining success of the restoration. A well fitting restoration needs to be accurate both along its margins and internal surface. This study was conducted to comparatively evaluate the marginal gap and internal gap of cobalt-chromium (Co-Cr) copings fabricated by conventional casting procedures and with direct metal laser sintering (DMLS) technique. Among the total of 30 test samples 10 cast copings were made from inlay casting wax and 10 from 3D printed resin pattern. 10 copings were obtained from DMLS technique. All the 30 test samples were then cemented sequentially on stainless steel model using pressure indicating paste and evaluated for vertical marginal gap in 8 predetermined reference areas. All copings were then removed and partially sectioned and cemented sequentially on same master model for evaluation of internal gap at 4 predetermined reference areas. Both marginal gap and internal gap were measured in microns using video measuring system (VMS2010F). The results obtained for both marginal and internal gap were statistically analyzed and the values fall within the clinically acceptable range. The DMLS technique had an edge over the other two techniques used, as it exhibited minimal gap in the marginal region which is an area of chief concern.

Entities:  

Keywords:  3D printed resin pattern; Direct metal laser sintering (DMLS); Internal gap; Marginal gap

Year:  2013        PMID: 24431733      PMCID: PMC3732698          DOI: 10.1007/s13191-013-0283-5

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  35 in total

1.  Dimensional accuracy of castings produced with ringless and metal ring investment systems.

Authors:  P Lombardas; A Carbunaru; M E McAlarney; R W Toothaker
Journal:  J Prosthet Dent       Date:  2000-07       Impact factor: 3.426

2.  Marginal accuracy and geometry of cast titanium copings.

Authors:  R Blackman; R Baez; N Barghi
Journal:  J Prosthet Dent       Date:  1992-04       Impact factor: 3.426

Review 3.  Considerations in measurement of marginal fit.

Authors:  J R Holmes; S C Bayne; G A Holland; W D Sulik
Journal:  J Prosthet Dent       Date:  1989-10       Impact factor: 3.426

4.  Periodontal considerations of restorative procedures.

Authors:  F Palomo; J Peden
Journal:  J Prosthet Dent       Date:  1976-10       Impact factor: 3.426

5.  Combination fixed and removable prostheses using a CoCr alloy: a clinical report.

Authors:  Stephane Viennot; Francis Dalard; Guillaume Malquarti; Brigitte Grosgogeat
Journal:  J Prosthet Dent       Date:  2006-08       Impact factor: 3.426

6.  Dimensional error of selective laser sintering, three-dimensional printing and PolyJet models in the reproduction of mandibular anatomy.

Authors:  Danilo Ibrahim; Tiago Leonardo Broilo; Claiton Heitz; Marília Gerhardt de Oliveira; Helena Willhelm de Oliveira; Stella Maris Wanderlei Nobre; José Henrique Gomes Dos Santos Filho; Daniela Nascimento Silva
Journal:  J Craniomaxillofac Surg       Date:  2008-12-03       Impact factor: 2.078

7.  Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns.

Authors:  Yurdanur Ucar; Tolga Akova; Musa S Akyil; William A Brantley
Journal:  J Prosthet Dent       Date:  2009-10       Impact factor: 3.426

8.  An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations.

Authors:  Philip L Tan; David G Gratton; Ana M Diaz-Arnold; David C Holmes
Journal:  J Prosthodont       Date:  2008-07       Impact factor: 2.752

9.  Effect of surface roughness and cement space on crown retention.

Authors:  N Juntavee; P L Millstein
Journal:  J Prosthet Dent       Date:  1992-09       Impact factor: 3.426

10.  Influence of convergence angle and cement space on adaptation of zirconium dioxide ceramic copings.

Authors:  Takayuki Iwai; Futoshi Komine; Kazuhisa Kobayashi; Ayako Saito; Hideo Matsumura
Journal:  Acta Odontol Scand       Date:  2008-08       Impact factor: 2.331

View more
  10 in total

1.  Fit of cobalt-chromium copings fabricated by the selective laser melting technology and casting method: A comparative evaluation using a profilometer.

Authors:  Koosha Gholamrezaei; Fariborz Vafaee; Behzad Fathi Afkari; Farnaz Firouz; Mozhgan Seif
Journal:  Dent Res J (Isfahan)       Date:  2020-05-23

2.  A Comparative Analysis of the Corrosive Effect of Artificial Saliva of Variable pH on DMLS and Cast Co-Cr-Mo Dental Alloy.

Authors:  Tatjana Puskar; Danimir Jevremovic; Robert J Williams; Dominic Eggbeer; Djordje Vukelic; Igor Budak
Journal:  Materials (Basel)       Date:  2014-09-11       Impact factor: 3.623

3.  Microcomputed tomography a noninvasive method to evaluate the fit of a restoration as compared to conventional replica technique.

Authors:  Sabita M Ram; Nishita Narendra Ranadive; Jyoti B Nadgere
Journal:  J Indian Prosthodont Soc       Date:  2019 Jul-Sep

4.  Development of a Computer-Aided Design and Finite Element Analysis Combined Method for Affordable Spine Surgical Navigation With 3D-Printed Customized Template.

Authors:  Peter Endre Eltes; Marton Bartos; Benjamin Hajnal; Agoston Jakab Pokorni; Laszlo Kiss; Damien Lacroix; Peter Pal Varga; Aron Lazary
Journal:  Front Surg       Date:  2021-01-25

Review 5.  Marginal and internal adaptation of lithium disilicate partial restorations: A systematic review and meta-analysis.

Authors:  Natália Almeida Bastos; Sandro Basso Bitencourt; Renan Figueiredo Carneiro; Brunna Mota Ferrairo; Samira Sandy Ferreira Strelhow; Daniela Micheline Dos Santos; Juliana Fraga Soares Bombonatti
Journal:  J Indian Prosthodont Soc       Date:  2020-10-08

6.  Clinical acceptability of metal-ceramic fixed partial dental prosthesis fabricated with direct metal laser sintering technique-5 year follow-up.

Authors:  Radhakrishnan Prabhu; Geetha Prabhu; Eswaran Baskaran; Eswaran M Arumugam
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

7.  A Comparison of the Marginal and Internal Fit of Cobalt- Chromium Copings Fabricated by Two Different CAD/CAM Systems (CAD/ Milling, CAD/ Ceramill Sintron).

Authors:  Mahroo Vojdani; Kianoosh Torabi; Berivan Atashkar; Hossein Heidari; Mahshid Torabi Ardakani
Journal:  J Dent (Shiraz)       Date:  2016-12

8.  Comparison of marginal and internal adaptation of copings fabricated from three different fabrication techniques: An in vitro study.

Authors:  Aman Arora; Avneet Yadav; Viram Upadhyaya; Prachi Jain; Mrinalini Verma
Journal:  J Indian Prosthodont Soc       Date:  2018 Apr-Jun

9.  Analyse the effect of different investment techniques and pattern materials on surface roughness of raw Ni-Cr castings - An In Vitro study.

Authors:  Aditi Aneesh Kanitkar; Aneesh Shriram Kanitkar; Rutuparna S Sasane; Seema S Patil; Swapnil R Chopade; Seema Vaidya
Journal:  J Indian Prosthodont Soc       Date:  2020-01-27

10.  Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study.

Authors:  Sujana Ullattuthodi; Kandathil Phillip Cherian; R Anandkumar; M Sreedevi Nambiar
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.