Literature DB >> 21455811

DRR and portal image registration for automatic patient positioning in radiotherapy treatment.

Ma Consuelo Bastida-Jumilla1, Jorge Larrey-Ruiz, Rafael Verdú-Monedero, Juan Morales-Sánchez, José-Luis Sancho-Gómez.   

Abstract

Image processing turns out to be essential in the planning and verification of radiotherapy treatments. Before applying a radiotherapy treatment, a dosimetry planning must be performed. Usually, the planning is done by means of an X-ray volumetric analysis using computerized tomography, where the area to be radiated is marked out. During the treatment phase, it is necessary to place the patient under the particle accelerator exactly as considered in the dosimetry stage. Coarse alignment is achieved using fiduciary markers placed over the patient's skin as external references. Later, fine alignment is provided by comparing a digitally reconstructed radiography (DRR) from the planning stage and a portal image captured by the accelerator in the treatment stage. The preprocessing of DRR and portal images, as well as the minimization of the non-shared information between both kinds of images, is mandatory for the correct operation of the image registration algorithm. With this purpose, mathematical morphology and image processing techniques have been used. The present work describes a fully automatic method to calculate more accurately the necessary displacement of the couch to place the patient exactly at the planned position. The proposed method to achieve the correct positioning of the patient is based on advanced image registration techniques. Preliminary results show a perfect match with the displacement estimated by the physician.

Entities:  

Mesh:

Year:  2011        PMID: 21455811      PMCID: PMC3222546          DOI: 10.1007/s10278-011-9376-z

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  9 in total

1.  Remote verification in radiotherapy using digitally reconstructed radiography (DRR) and portal images: a pilot study.

Authors:  S Hashimoto; H Shirato; T Nishioka; K Kagei; S Shimizu; K Fujita; H Ogasawara; Y Watanabe; K Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-06-01       Impact factor: 7.038

2.  Quantitative measurement of MLC leaf displacements using an electronic portal image device.

Authors:  Yong Yang; Lei Xing
Journal:  Phys Med Biol       Date:  2004-04-21       Impact factor: 3.609

3.  Engineering and algorithm design for an image processing Api: a technical report on ITK--the Insight Toolkit.

Authors:  Terry S Yoo; Michael J Ackerman; William E Lorensen; Will Schroeder; Vikram Chalana; Stephen Aylward; Dimitris Metaxas; Ross Whitaker
Journal:  Stud Health Technol Inform       Date:  2002

4.  Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy.

Authors:  Ali Khamene; Peter Bloch; Wolfgang Wein; Michelle Svatos; Frank Sauer
Journal:  Med Image Anal       Date:  2005-09-08       Impact factor: 8.545

5.  Radiation field edge detection in portal images.

Authors:  J Bijhold; K G Gilhuijs; M van Herk; H Meertens
Journal:  Phys Med Biol       Date:  1991-12       Impact factor: 3.609

6.  Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers.

Authors:  J Wu; T Haycocks; H Alasti; G Ottewell; N Middlemiss; M Abdolell; P Warde; A Toi; C Catton
Journal:  Radiother Oncol       Date:  2001-11       Impact factor: 6.280

7.  Registration of DRRs and portal images for verification of stereotactic body radiotherapy: a feasibility study in lung cancer treatment.

Authors:  Thomas Künzler; Jozef Grezdo; Joachim Bogner; Wolfgang Birkfellner; Dietmar Georg
Journal:  Phys Med Biol       Date:  2007-03-26       Impact factor: 3.609

8.  Registration of electronic portal images for patient set-up verification.

Authors:  George K Matsopoulos; Pantelis A Asvestas; Konstantinos K Delibasis; Vassilios Kouloulias; Nikolaos Uzunoglu; Pantelis Karaiskos; Panagiotis Sandilos
Journal:  Phys Med Biol       Date:  2004-07-21       Impact factor: 3.609

9.  Patient setup error measurement using 3D intensity-based image registration techniques.

Authors:  Sébastien Clippe; David Sarrut; Claude Malet; Serge Miguet; Chantal Ginestet; Christian Carrie
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-05-01       Impact factor: 7.038

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.