Literature DB >> 12594755

Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state.

Sean C L Deoni1, Brian K Rutt, Terry M Peters.   

Abstract

A novel, fully 3D, high-resolution T(1) and T(2) relaxation time mapping method is presented. The method is based on steady-state imaging with T(1) and T(2) information derived from either spoiling or fully refocusing the transverse magnetization following each excitation pulse. T(1) is extracted from a pair of spoiled gradient recalled echo (SPGR) images acquired at optimized flip angles. This T(1) information is combined with two refocused steady-state free precession (SSFP) images to determine T(2). T(1) and T(2) accuracy was evaluated against inversion recovery (IR) and spin-echo (SE) results, respectively. Error within the T(1) and T(2) maps, determined from both phantom and in vivo measurements, is approximately 7% for T(1) between 300 and 2000 ms and 7% for T(2) between 30 and 150 ms. The efficiency of the method, defined as the signal-to-noise ratio (SNR) of the final map per voxel volume per square root scan time, was evaluated against alternative mapping methods. With an efficiency of three times that of multipoint IR and three times that of multiecho SE, our combined approach represents the most efficient of those examined. Acquisition time for a whole brain T(1) map (25 x 25 x 10 cm) is less than 8 min with 1 mm(3) isotropic voxels. An additional 7 min is required for an identically sized T(2) map and postprocessing time is less than 1 min on a 1 GHz PIII PC. The method therefore permits real-time clinical acquisition and display of whole brain T(1) and T(2) maps for the first time. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12594755     DOI: 10.1002/mrm.10407

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  230 in total

1.  Quantitative MR imaging of two-pool magnetization transfer model parameters in myelin mutant shaking pup.

Authors:  Alexey Samsonov; Andrew L Alexander; Pouria Mossahebi; Yu-Chien Wu; Ian D Duncan; Aaron S Field
Journal:  Neuroimage       Date:  2012-06-01       Impact factor: 6.556

2.  Low rank alternating direction method of multipliers reconstruction for MR fingerprinting.

Authors:  Jakob Assländer; Martijn A Cloos; Florian Knoll; Daniel K Sodickson; Jürgen Hennig; Riccardo Lattanzi
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

3.  A customizable MR brain imaging atlas of structure and function for decision support.

Authors:  U Sinha; S El-Saden; G Duckwiler; L Thompson; S Ardekani; H Kangarloo
Journal:  AMIA Annu Symp Proc       Date:  2003

4.  Novel whole brain segmentation and volume estimation using quantitative MRI.

Authors:  J West; J B M Warntjes; P Lundberg
Journal:  Eur Radiol       Date:  2011-11-24       Impact factor: 5.315

5.  Optimal MRI methods for direct stereotactic targeting of the subthalamic nucleus and globus pallidus.

Authors:  Ruth L O'Gorman; Karin Shmueli; Keyoumars Ashkan; Michael Samuel; David J Lythgoe; Asal Shahidiani; Stephen J Wastling; Michelle Footman; Richard P Selway; Jozef Jarosz
Journal:  Eur Radiol       Date:  2010-07-21       Impact factor: 5.315

6.  Incorporation of nonzero echo times in the SPGR and bSSFP signal models used in mcDESPOT.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-09-26       Impact factor: 4.668

7.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

8.  Novel contrast mixture achieves contrast resolution of human bladder wall suitable for T1 mapping: applications in interstitial cystitis and beyond.

Authors:  Pradeep Tyagi; Joseph Janicki; Chan-Hong Moon; Jonathan Kaufman; Christopher Chermansky
Journal:  Int Urol Nephrol       Date:  2018-02-01       Impact factor: 2.370

9.  Validation of dynamic contrast-enhanced magnetic resonance imaging-derived vascular permeability measurements using quantitative autoradiography in the RG2 rat brain tumor model.

Authors:  Moira C Ferrier; Hemant Sarin; Steve H Fung; Bawarjan Schatlo; Ryszard M Pluta; Sandeep N Gupta; Peter L Choyke; Edward H Oldfield; David Thomasson; John A Butman
Journal:  Neoplasia       Date:  2007-07       Impact factor: 5.715

10.  Respiratory motion-compensated radial dynamic contrast-enhanced (DCE)-MRI of chest and abdominal lesions.

Authors:  Wei Lin; Junyu Guo; Mark A Rosen; Hee Kwon Song
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.