Literature DB >> 21398063

Retrospectively gated cardiac cine imaging with temporal and spatial acceleration.

Bruno Madore1, W Scott Hoge, Tzu-Cheng Chao, Gary P Zientara, Renxin Chu.   

Abstract

Parallel imaging methods are routinely used to accelerate the image acquisition process in cardiac cine imaging. The addition of a temporal acceleration method, whereby k-space is sampled differently for different time frames, has been shown in prior work to improve image quality as compared to parallel imaging by itself. However, such temporal acceleration strategies prove difficult to combine with retrospectively gated cine imaging. The only currently published method to feature such combination, by Hansen et al. [Magn Reson Med 55 (2006) 85-91] tends to be associated with prohibitively long reconstruction times. The goal of the present work was to develop a retrospectively gated cardiac cine method that features both parallel imaging and temporal acceleration, capable of achieving significant acceleration factors on commonly available hardware and associated with reconstruction times short enough for practical use in a clinical context. Seven cardiac patients and a healthy volunteer were recruited and imaged, with acceleration factors of 3.5 or 4.5, using an eight-channel product cardiac array on a 1.5-T system. The prescribed FOV value proved slightly too small in three patients, and one of the patients had a bigemini condition. Despite these additional challenges, good-quality results were obtained for all slices and all patients, with a reconstruction time of 0.98±0.07 s per frame, or about 20 s for a 20-frame slice, using a single processor on a single PC. As compared to using parallel imaging by itself, the addition of a temporal acceleration strategy provided much resistance to artifacts.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21398063      PMCID: PMC3079346          DOI: 10.1016/j.mri.2011.01.003

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  14 in total

1.  Adaptive sensitivity encoding incorporating temporal filtering (TSENSE).

Authors:  P Kellman; F H Epstein; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-05       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Using UNFOLD to remove artifacts in parallel imaging and in partial-Fourier imaging.

Authors:  Bruno Madore
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

4.  k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations.

Authors:  Jeffrey Tsao; Peter Boesiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

5.  UNFOLD-SENSE: a parallel MRI method with self-calibration and artifact suppression.

Authors:  Bruno Madore
Journal:  Magn Reson Med       Date:  2004-08       Impact factor: 4.668

6.  k-t BLAST reconstruction from non-Cartesian k-t space sampling.

Authors:  Michael S Hansen; Christof Baltes; Jeffrey Tsao; Sebastian Kozerke; Klaas P Pruessmann; Holger Eggers
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

7.  Retrospective cardiac gating: a review of technical aspects and future directions.

Authors:  G W Lenz; E M Haacke; R D White
Journal:  Magn Reson Imaging       Date:  1989 Sep-Oct       Impact factor: 2.546

8.  Cine MR determination of left ventricular ejection fraction.

Authors:  J A Utz; R J Herfkens; J A Heinsimer; T Bashore; R Califf; G Glover; N Pelc; A Shimakawa
Journal:  AJR Am J Roentgenol       Date:  1987-05       Impact factor: 3.959

9.  K-space description for MR imaging of dynamic objects.

Authors:  Q S Xiang; R M Henkelman
Journal:  Magn Reson Med       Date:  1993-03       Impact factor: 4.668

Review 10.  Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods.

Authors:  Sebastian Kozerke; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2008-06-05       Impact factor: 5.364

View more
  4 in total

Review 1.  Mechanotransduction mechanisms for intraventricular diastolic vortex forces and myocardial deformations: part 1.

Authors:  Ares Pasipoularides
Journal:  J Cardiovasc Transl Res       Date:  2015-01-27       Impact factor: 4.132

Review 2.  Diastolic filling vortex forces and cardiac adaptations: probing the epigenetic nexus.

Authors:  Ares Pasipoularides
Journal:  Hellenic J Cardiol       Date:  2012 Nov-Dec

3.  Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T.

Authors:  Marcus Carlsson; Johannes Töger; Mikael Kanski; Karin Markenroth Bloch; Freddy Ståhlberg; Einar Heiberg; Håkan Arheden
Journal:  J Cardiovasc Magn Reson       Date:  2011-10-04       Impact factor: 5.364

Review 4.  Breakthroughs in modern cancer therapy and elusive cardiotoxicity: Critical research-practice gaps, challenges, and insights.

Authors:  Ping-Pin Zheng; Jin Li; Johan M Kros
Journal:  Med Res Rev       Date:  2017-09-01       Impact factor: 12.944

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.