Using UNFOLD to remove artifacts in parallel imaging and in partial-Fourier imaging.

Bruno Madore1.   

Abstract

In dynamic MRI, it is often difficult to achieve the acquisition speed required to resolve or freeze the temporal variations of the imaged object. Several MRI methods aim at speeding up the image acquisition process. Through assumptions and/or prior knowledge, these dynamic MRI methods allow part of the needed data to be calculated instead of acquired. For example, partial-Fourier imaging assumes that phase varies smoothly within the object, and parallel imaging (e.g., simultaneous acquisition of spatial harmonics (SMASH) and sensitivity encoding (SENSE)) uses prior knowledge about receiver-coil sensitivity. While these methods accelerate acquisition, they can introduce artifacts or amplify noise in doing so. The present work aims at accelerating image acquisition significantly, while introducing almost no artifacts or noise amplification. It is shown here that new, extra information is gained if dynamic MRI methods are modified so that the sampling function changes in specific ways from time-frame to time-frame. In other words, the set of k-space locations that are acquired (instead of calculated) changes with time. The present temporal strategy, based on the UNaliasing by Fourier-encoding the Overlaps in the temporaL Dimension (UNFOLD) method, can be incorporated into common dynamic MRI methods. Results with partial-Fourier, SMASH, and SENSE imaging are presented here, where UNFOLD's contribution is to very significantly reduce the artifact and/or amplified noise content. Used in this way, UNFOLD contributes indirectly, rather than directly to the improvement in image acquisition speed, as it allows companion methods to operate properly at greater acceleration settings than would otherwise be feasible. Copyright 2002 Wiley-Liss, Inc.

Mesh:

Year:  2002        PMID: 12210914     DOI: 10.1002/mrm.10229

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD.

Authors:  Michael A Guttman; Peter Kellman; Alexander J Dick; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

2.  3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI.

Authors:  Dana C Peters; Daniel B Ennis; Pratik Rohatgi; Mushabbar A Syed; Elliot R McVeigh; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2004-09       Impact factor: 4.813

3.  Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view.

Authors:  Dana C Peters; Michael A Guttman; Alexander J Dick; Venkatesh K Raman; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

4.  Functional MRI using regularized parallel imaging acquisition.

Authors:  Fa-Hsuan Lin; Teng-Yi Huang; Nan-Kuei Chen; Fu-Nien Wang; Steven M Stufflebeam; John W Belliveau; Lawrence L Wald; Kenneth K Kwong
Journal:  Magn Reson Med       Date:  2005-08       Impact factor: 4.668

5.  Excitation UNFOLD (XUNFOLD) to improve the temporal resolution of multishot tailored RF pulses.

Authors:  V Andrew Stenger; Marius S Giurgi; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

6.  Analytic image concept combined to SENSE reconstruction.

Authors:  Josiane Yankam Njiwa; Christof Baltes; Markus Rudin
Journal:  MAGMA       Date:  2011-08-11       Impact factor: 2.310

7.  Improved PRF-based MR thermometry using k-space energy spectrum analysis.

Authors:  Shenyan Zong; Guofeng Shen; Chang-Sheng Mei; Bruno Madore
Journal:  Magn Reson Med       Date:  2020-06-25       Impact factor: 4.668

8.  Non-Cartesian slice-GRAPPA and slice-SPIRiT reconstruction methods for multiband spiral cardiac MRI.

Authors:  Changyu Sun; Yang Yang; Xiaoying Cai; Michael Salerno; Craig H Meyer; Daniel Weller; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2019-09-30       Impact factor: 4.668

9.  Interleaved spiral-in/out with application to functional MRI (fMRI).

Authors:  Christine S Law; Gary H Glover
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

10.  A 2D MTF approach to evaluate and guide dynamic imaging developments.

Authors:  Tzu-Cheng Chao; Hsiao-Wen Chung; W Scott Hoge; Bruno Madore
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.