Literature DB >> 15282813

UNFOLD-SENSE: a parallel MRI method with self-calibration and artifact suppression.

Bruno Madore1.   

Abstract

This work aims at improving the performance of parallel imaging by using it with our "unaliasing by Fourier-encoding the overlaps in the temporal dimension" (UNFOLD) temporal strategy. A self-calibration method called "self, hybrid referencing with UNFOLD and GRAPPA" (SHRUG) is presented. SHRUG combines the UNFOLD-based sensitivity mapping strategy introduced in the TSENSE method by Kellman et al. (5), with the strategy introduced in the GRAPPA method by Griswold et al. (10). SHRUG merges the two approaches to alleviate their respective limitations, and provides fast self-calibration at any given acceleration factor. UNFOLD-SENSE further includes an UNFOLD artifact suppression scheme to significantly suppress artifacts and amplified noise produced by parallel imaging. This suppression scheme, which was published previously (4), is related to another method that was presented independently as part of TSENSE. While the two are equivalent at accelerations < or = 2.0, the present approach is shown here to be significantly superior at accelerations > 2.0, with up to double the artifact suppression at high accelerations. Furthermore, a slight modification of Cartesian SENSE is introduced, which allows departures from purely Cartesian sampling grids. This technique, termed variable-density SENSE (vdSENSE), allows the variable-density data required by SHRUG to be reconstructed with the simplicity and fast processing of Cartesian SENSE. UNFOLD-SENSE is given by the combination of SHRUG for sensitivity mapping, vdSENSE for reconstruction, and UNFOLD for artifact/amplified noise suppression. The method was implemented, with online reconstruction, on both an SSFP and a myocardium-perfusion sequence. The results from six patients scanned with UNFOLD-SENSE are presented.

Entities:  

Mesh:

Year:  2004        PMID: 15282813     DOI: 10.1002/mrm.20133

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Dynamic field-of-view imaging to increase temporal resolution in the early phase of contrast media uptake in breast DCE-MRI: A feasibility study.

Authors:  Federico D Pineda; Ty O Easley; Gregory S Karczmar
Journal:  Med Phys       Date:  2018-01-24       Impact factor: 4.071

2.  Functional MRI using regularized parallel imaging acquisition.

Authors:  Fa-Hsuan Lin; Teng-Yi Huang; Nan-Kuei Chen; Fu-Nien Wang; Steven M Stufflebeam; John W Belliveau; Lawrence L Wald; Kenneth K Kwong
Journal:  Magn Reson Med       Date:  2005-08       Impact factor: 4.668

Review 3.  Highly accelerated cardiovascular MR imaging using many channel technology: concepts and clinical applications.

Authors:  Thoralf Niendorf; Daniel K Sodickson
Journal:  Eur Radiol       Date:  2007-06-12       Impact factor: 5.315

4.  Analytic image concept combined to SENSE reconstruction.

Authors:  Josiane Yankam Njiwa; Christof Baltes; Markus Rudin
Journal:  MAGMA       Date:  2011-08-11       Impact factor: 2.310

5.  Self-supervised learning of physics-guided reconstruction neural networks without fully sampled reference data.

Authors:  Burhaneddin Yaman; Seyed Amir Hossein Hosseini; Steen Moeller; Jutta Ellermann; Kâmil Uğurbil; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2020-07-02       Impact factor: 4.668

6.  Breathheld autocalibrated phase-contrast imaging.

Authors:  Calvin Lew; Marcus T Alley; Daniel M Spielman; Roland Bammer; Frandics P Chan
Journal:  J Magn Reson Imaging       Date:  2010-04       Impact factor: 4.813

7.  Null space imaging: nonlinear magnetic encoding fields designed complementary to receiver coil sensitivities for improved acceleration in parallel imaging.

Authors:  Leo K Tam; Jason P Stockmann; Gigi Galiana; R Todd Constable
Journal:  Magn Reson Med       Date:  2011-12-21       Impact factor: 4.668

8.  Real-time cardiac MRI using prior spatial-spectral information.

Authors:  Cornelius Brinegar; Haosen Zhang; Yi-Jen L Wu; Lesley M Foley; T Hitchens; Qing Ye; Darren Pocci; Fan Lam; Chien Ho; Zhi-Pei Liang
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

9.  A 2D MTF approach to evaluate and guide dynamic imaging developments.

Authors:  Tzu-Cheng Chao; Hsiao-Wen Chung; W Scott Hoge; Bruno Madore
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

10.  Accelerated focused ultrasound imaging.

Authors:  Bruno Madore; P Jason White; Kai Thomenius; Gregory T Clement
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-12       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.