Literature DB >> 2607896

Retrospective cardiac gating: a review of technical aspects and future directions.

G W Lenz1, E M Haacke, R D White.   

Abstract

The advent of short TR gradient-echo imaging has made it possible to acquire cine images of the heart with conventional whole body MRI scanners. In this paper, technical details of the data collection and image reconstruction process for cine MRI using retrospective cardiac gating are presented. Specifically, the following issues are discussed: data sorting and interpolation; time resolution; motion compensation and phase information; the type of steady state sequence including optimal flip angle; respiratory motion and correction; and the potential of 3D imaging.

Mesh:

Year:  1989        PMID: 2607896     DOI: 10.1016/0730-725x(89)90399-8

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  20 in total

1.  Magnetic resonance coronary artery imaging.

Authors:  C B Paschal; E M Haacke; L P Adler; D A Finelli
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

2.  Cardiorespiratory-resolved magnetic resonance imaging: measuring respiratory modulation of cardiac function.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

Review 3.  Motion correction options in PET/MRI.

Authors:  Ciprian Catana
Journal:  Semin Nucl Med       Date:  2015-05       Impact factor: 4.446

4.  k-t BLAST and SENSE accelerated time-resolved three-dimensional phase contrast MRI in an intracranial aneurysm.

Authors:  Pim van Ooij; Annetje Guédon; Henk A Marquering; Joppe J Schneiders; Charles B Majoie; Ed van Bavel; Aart J Nederveen
Journal:  MAGMA       Date:  2012-09-07       Impact factor: 2.310

Review 5.  Tools for cardiovascular magnetic resonance imaging.

Authors:  Ramkumar Krishnamurthy; Benjamin Cheong; Raja Muthupillai
Journal:  Cardiovasc Diagn Ther       Date:  2014-04

6.  Self-gated golden angle spiral cine MRI for coronary endothelial function assessment.

Authors:  Gabriele Bonanno; Allison G Hays; Robert G Weiss; Michael Schär
Journal:  Magn Reson Med       Date:  2017-12-27       Impact factor: 4.668

7.  Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction.

Authors:  Michael S Hansen; Thomas S Sørensen; Andrew E Arai; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-12-21       Impact factor: 4.668

8.  Self-gated MRI of multiple beat morphologies in the presence of arrhythmias.

Authors:  Francisco Contijoch; Srikant Kamesh Iyer; James J Pilla; Paul Yushkevich; Joseph H Gorman; Robert C Gorman; Harold Litt; Yuchi Han; Walter R T Witschey
Journal:  Magn Reson Med       Date:  2016-08-31       Impact factor: 4.668

Review 9.  Image reconstruction: an overview for clinicians.

Authors:  Michael S Hansen; Peter Kellman
Journal:  J Magn Reson Imaging       Date:  2014-06-25       Impact factor: 4.813

10.  Novel retrospective, respiratory-gating method enables 3D, high resolution, dynamic imaging of the upper airway during tidal breathing.

Authors:  Mark E Wagshul; Sanghun Sin; Michael L Lipton; Keivan Shifteh; Raanan Arens
Journal:  Magn Reson Med       Date:  2013-02-07       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.