Real-time motion and B0 corrected single voxel spectroscopy using volumetric navigators.

Aaron T Hess1, M Dylan Tisdall, Ovidiu C Andronesi, Ernesta M Meintjes, André J W van der Kouwe.   

Abstract

In population groups where head pose cannot be assumed to be constant during a magnetic resonance spectroscopy examination or in difficult-to-shim regions of the brain, real-time volume of interest, frequency, and shim optimization may be necessary. We investigate the effect of pose change on the B0 homogeneity of a (2 cm)3 volume and observe typical first-order shim changes of 1 μT/m per 1° rotation (chin down to up) in four different volumes of interest in a single volunteer. An echo planar imaging volume navigator was constructed to measure and apply in real-time within each pulse repetition time: volume of interest positioning, frequency adjustment, and first-order shim adjustment. This volume navigator is demonstrated in six healthy volunteers and achieved a mean linewidth of 4.4 Hz, similar to that obtained by manual shim adjustment of 4.9 Hz. Furthermore, this linewidth is maintained by the volume navigator at 4.9 Hz in the presence of pose change. By comparison, a mean linewidth of 7.5 Hz was observed, when no correction was applied. Copyright &© 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21381101      PMCID: PMC3123687          DOI: 10.1002/mrm.22805

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Restoration of motion-related signal loss and line-shape deterioration of proton MR spectra using the residual water as intrinsic reference.

Authors:  G Helms; A Piringer
Journal:  Magn Reson Med       Date:  2001-08       Impact factor: 4.668

2.  Spherical navigator echoes for full 3D rigid body motion measurement in MRI.

Authors:  Edward Brian Welch; Armando Manduca; Roger C Grimm; Heidi A Ward; Clifford R Jack
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

3.  Phase coherent averaging in magnetic resonance spectroscopy using interleaved navigator scans: compensation of motion artifacts and magnetic field instabilities.

Authors:  Thorsten Thiel; Michael Czisch; Gregor K Elbel; Juergen Hennig
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

4.  Fast, automated, N-dimensional phase-unwrapping algorithm.

Authors:  Mark Jenkinson
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

5.  Inhomogeneity correction for in vivo spectroscopy by high-resolution water referencing.

Authors:  P Webb; D Spielman; A Macovski
Journal:  Magn Reson Med       Date:  1992-01       Impact factor: 4.668

Review 6.  Spatial localization in NMR spectroscopy in vivo.

Authors:  P A Bottomley
Journal:  Ann N Y Acad Sci       Date:  1987       Impact factor: 5.691

7.  Orbital navigator echoes for motion measurements in magnetic resonance imaging.

Authors:  Z W Fu; Y Wang; R C Grimm; P J Rossman; J P Felmlee; S J Riederer; R L Ehman
Journal:  Magn Reson Med       Date:  1995-11       Impact factor: 4.668

8.  Motion correction and lipid suppression for 1H magnetic resonance spectroscopy.

Authors:  J M Star-Lack; E Adalsteinsson; G E Gold; D M Ikeda; D M Spielman
Journal:  Magn Reson Med       Date:  2000-03       Impact factor: 4.668

9.  Prospective motion correction for single-voxel 1H MR spectroscopy.

Authors:  Brian Keating; Weiran Deng; J Cooper Roddey; Nathan White; Anders Dale; V Andrew Stenger; Thomas Ernst
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

10.  Estimation of metabolite concentrations from localized in vivo proton NMR spectra.

Authors:  S W Provencher
Journal:  Magn Reson Med       Date:  1993-12       Impact factor: 4.668

View more
  64 in total

Review 1.  Detection of oncogenic IDH1 mutations using magnetic resonance spectroscopy of 2-hydroxyglutarate.

Authors:  Ovidiu C Andronesi; Otto Rapalino; Elizabeth Gerstner; Andrew Chi; Tracy T Batchelor; Dan P Cahill; A Gregory Sorensen; Bruce R Rosen
Journal:  J Clin Invest       Date:  2013-09-03       Impact factor: 14.808

2.  Correction of B 0-induced geometric distortion variations in prospective motion correction for 7T MRI.

Authors:  Uten Yarach; Chaiya Luengviriya; Daniel Stucht; Frank Godenschweger; Peter Schulze; Oliver Speck
Journal:  MAGMA       Date:  2016-02-09       Impact factor: 2.310

3.  Real-time simultaneous shim and motion measurement and correction in glycoCEST MRI using double volumetric navigators (DvNavs).

Authors:  Gizeaddis L Simegn; Andre J W Van der Kouwe; Frances C Robertson; Ernesta M Meintjes; Ali Alhamud
Journal:  Magn Reson Med       Date:  2018-12-02       Impact factor: 4.668

4.  Improved localization, spectral quality, and repeatability with advanced MRS methodology in the clinical setting.

Authors:  Dinesh K Deelchand; Kejal Kantarci; Gülin Öz
Journal:  Magn Reson Med       Date:  2017-06-15       Impact factor: 4.668

5.  Prospective motion correction with volumetric navigators (vNavs) reduces the bias and variance in brain morphometry induced by subject motion.

Authors:  M Dylan Tisdall; Martin Reuter; Abid Qureshi; Randy L Buckner; Bruce Fischl; André J W van der Kouwe
Journal:  Neuroimage       Date:  2015-12-02       Impact factor: 6.556

6.  Real-time Correction of Motion and Imager Instability Artifacts during 3D γ-Aminobutyric Acid-edited MR Spectroscopic Imaging.

Authors:  Eva Heckova; Michal Považan; Bernhard Strasser; Patrik Krumpolec; Petra Hnilicová; Gilbert J Hangel; Philipp A Moser; Ovidiu C Andronesi; Andre J van der Kouwe; Peter Valkovic; Barbara Ukropcova; Siegfried Trattnig; Wolfgang Bogner
Journal:  Radiology       Date:  2017-09-28       Impact factor: 11.105

7.  Automatic voxel positioning for MRS at 7 T.

Authors:  Weiqiang Dou; Oliver Speck; Thomas Benner; Jörn Kaufmann; Meng Li; Kai Zhong; Martin Walter
Journal:  MAGMA       Date:  2014-11-20       Impact factor: 2.310

Review 8.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

9.  Prospective frequency correction using outer volume suppression-localized navigator for MR spectroscopy and spectroscopic imaging.

Authors:  Chu-Yu Lee; In-Young Choi; Phil Lee
Journal:  Magn Reson Med       Date:  2018-05-13       Impact factor: 4.668

10.  HIV-associated CD4+/CD8+ depletion in infancy is associated with neurometabolic reductions in the basal ganglia at age 5 years despite early antiretroviral therapy.

Authors:  Kenneth K Mbugua; Martha J Holmes; Mark F Cotton; Eva-Maria Ratai; Francesca Little; Aaron T Hess; Els Dobbels; Andre J W Van der Kouwe; Barbara Laughton; Ernesta M Meintjes
Journal:  AIDS       Date:  2016-06-01       Impact factor: 4.177

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.