Literature DB >> 28957645

Real-time Correction of Motion and Imager Instability Artifacts during 3D γ-Aminobutyric Acid-edited MR Spectroscopic Imaging.

Eva Heckova1, Michal Považan1, Bernhard Strasser1, Patrik Krumpolec1, Petra Hnilicová1, Gilbert J Hangel1, Philipp A Moser1, Ovidiu C Andronesi1, Andre J van der Kouwe1, Peter Valkovic1, Barbara Ukropcova1, Siegfried Trattnig1, Wolfgang Bogner1.   

Abstract

Purpose To compare the involuntary head motion, frequency and B0 shim changes, and effects on data quality during real-time-corrected three-dimensional γ-aminobutyric acid-edited magnetic resonance (MR) spectroscopic imaging in subjects with mild cognitive impairment (MCI), patients with Parkinson disease (PD), and young and older healthy volunteers. Materials and Methods In this prospective study, MR spectroscopic imaging datasets were acquired at 3 T after written informed consent was obtained. Translational and rotational head movement, frequency, and B0 shim were determined with an integrated volumetric navigator. Head motion patterns and imager instability were investigated in 33 young healthy control subjects (mean age ± standard deviation, 31 years ± 5), 34 older healthy control subjects (mean age, 67 years ± 8), 34 subjects with MCI (mean age, 72 years ± 5), and 44 patients with PD (mean age, 64 years ± 8). Spectral quality was assessed by means of region-of-interest analysis. Group differences were evaluated with Bonferroni-corrected Mann-Whitney tests. Results Three patients with PD and four subjects with MCI were excluded because of excessive head motion (ie, > 0.8 mm translation per repetition time of 1.6 seconds throughout >10 minutes). Older control subjects, patients with PD, and subjects with MCI demonstrated 1.5, 2, and 2.5 times stronger head movement, respectively, than did young control subjects (1.79 mm ± 0.77) (P < .001). Of young control subjects, older control subjects, patients with PD, and subjects with MCI, 6%, 35%, 38%, and 51%, respectively, moved more than 3 mm during the MR spectroscopic imaging acquisition of approximately 20 minutes. The predominant movements were head nodding and "sliding out" of the imager. Frequency changes were 1.1- and 1.4-fold higher in patients with PD (P = .007) and subjects with MCI (P < .001), respectively, and B0 shim changes were 1.3-, 1.5-, and 1.9-fold higher in older control subjects (P = .005), patients with PD (P < .001), and patients with MCI (P < .001), respectively, compared with those of young control subjects (12.59 Hz ± 2.49, 3.61 Hz · cm-1 ± 1.25). Real-time correction provided high spectral quality in all four groups (signal-to-noise ratio >15, Cramér-Rao lower bounds < 20%). Conclusion Real-time motion and B0 monitoring provides valuable information about motion patterns and B0 field variations in subjects with different predispositions for head movement. Immediate correction improves data quality, particularly in patients who have difficulty avoiding movement. © RSNA, 2017 Online supplemental material is available for this article.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28957645      PMCID: PMC5790304          DOI: 10.1148/radiol.2017170744

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  25 in total

1.  Detection and correction of frequency instabilities for volumetric 1H echo-planar spectroscopic imaging.

Authors:  Andreas Ebel; Andrew A Maudsley
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

Review 2.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

3.  Proton MR spectroscopy-detectable major neurotransmitters of the brain: biology and possible clinical applications.

Authors:  N Agarwal; P F Renshaw
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-29       Impact factor: 3.825

4.  Real-time motion and B0 corrected single voxel spectroscopy using volumetric navigators.

Authors:  Aaron T Hess; M Dylan Tisdall; Ovidiu C Andronesi; Ernesta M Meintjes; André J W van der Kouwe
Journal:  Magn Reson Med       Date:  2011-03-04       Impact factor: 4.668

5.  Edited magnetic resonance spectroscopy detects an age-related decline in brain GABA levels.

Authors:  Fei Gao; Richard A E Edden; Muwei Li; Nicolaas A J Puts; Guangbin Wang; Cheng Liu; Bin Zhao; Huiquan Wang; Xue Bai; Chen Zhao; Xin Wang; Peter B Barker
Journal:  Neuroimage       Date:  2013-04-13       Impact factor: 6.556

6.  Subtraction artifacts and frequency (mis-)alignment in J-difference GABA editing.

Authors:  C John Evans; Nicolaas A J Puts; Siân E Robson; Frederic Boy; David J McGonigle; Petroc Sumner; Krish D Singh; Richard A E Edden
Journal:  J Magn Reson Imaging       Date:  2012-11-27       Impact factor: 4.813

Review 7.  Clinical proton MR spectroscopy in central nervous system disorders.

Authors:  Gülin Oz; Jeffry R Alger; Peter B Barker; Robert Bartha; Alberto Bizzi; Chris Boesch; Patrick J Bolan; Kevin M Brindle; Cristina Cudalbu; Alp Dinçer; Ulrike Dydak; Uzay E Emir; Jens Frahm; Ramón Gilberto González; Stephan Gruber; Rolf Gruetter; Rakesh K Gupta; Arend Heerschap; Anke Henning; Hoby P Hetherington; Franklyn A Howe; Petra S Hüppi; Ralph E Hurd; Kantarci Kantarci; Dennis W J Klomp; Roland Kreis; Marijn J Kruiskamp; Martin O Leach; Alexander P Lin; Peter R Luijten; Malgorzata Marjańska; Andrew A Maudsley; Dieter J Meyerhoff; Carolyn E Mountford; Sarah J Nelson; M Necmettin Pamir; Jullie W Pan; Andrew C Peet; Harish Poptani; Stefan Posse; Petra J W Pouwels; Eva-Maria Ratai; Brian D Ross; Tom W Scheenen; Christian Schuster; Ian C P Smith; Brian J Soher; Ivan Tkáč; Daniel B Vigneron; Risto A Kauppinen
Journal:  Radiology       Date:  2014-03       Impact factor: 11.105

8.  Real-time motion- and B0-correction for LASER-localized spiral-accelerated 3D-MRSI of the brain at 3T.

Authors:  Wolfgang Bogner; Aaron T Hess; Borjan Gagoski; M Dylan Tisdall; Andre J W van der Kouwe; Siegfried Trattnig; Bruce Rosen; Ovidiu C Andronesi
Journal:  Neuroimage       Date:  2013-11-05       Impact factor: 6.556

9.  Quality of 186 child brain spectra using motion and B0 shim navigated single voxel spectroscopy.

Authors:  Aaron T Hess; André J W van der Kouwe; Kenneth K Mbugua; Barbara Laughton; Ernesta M Meintjes
Journal:  J Magn Reson Imaging       Date:  2013-11-04       Impact factor: 4.813

10.  Spatial variability and reproducibility of GABA-edited MEGA-LASER 3D-MRSI in the brain at 3 T.

Authors:  Petra Hnilicová; Michal Považan; Bernhard Strasser; Ovidiu C Andronesi; Martin Gajdošík; Ulrike Dydak; Jozef Ukropec; Dušan Dobrota; Siegfried Trattnig; Wolfgang Bogner
Journal:  NMR Biomed       Date:  2016-10-07       Impact factor: 4.044

View more
  10 in total

1.  Combining multiband slice selection with consistent k-t-space EPSI for accelerated spectral imaging.

Authors:  Rita Schmidt; Amir Seginer; Assaf Tal
Journal:  Magn Reson Med       Date:  2019-04-16       Impact factor: 4.668

2.  Reproducibility of 7-T brain spectroscopy using an ultrashort echo time STimulated Echo Acquisition Mode sequence and automated voxel repositioning.

Authors:  Meredith A Reid; Martha R Forloines; Nouha Salibi
Journal:  NMR Biomed       Date:  2021-10-08       Impact factor: 4.044

3.  Whole-slice mapping of GABA and GABA+ at 7T via adiabatic MEGA-editing, real-time instability correction, and concentric circle readout.

Authors:  Philipp Moser; Lukas Hingerl; Bernhard Strasser; Michal Považan; Gilbert Hangel; Ovidiu C Andronesi; Andre van der Kouwe; Stephan Gruber; Siegfried Trattnig; Wolfgang Bogner
Journal:  Neuroimage       Date:  2018-09-19       Impact factor: 6.556

Review 4.  Motion correction in magnetic resonance spectroscopy.

Authors:  Muhammad G Saleh; Richard A E Edden; Linda Chang; Thomas Ernst
Journal:  Magn Reson Med       Date:  2020-04-17       Impact factor: 3.737

5.  Non-Cartesian GRAPPA and coil combination using interleaved calibration data - application to concentric-ring MRSI of the human brain at 7T.

Authors:  Philipp Moser; Wolfgang Bogner; Lukas Hingerl; Eva Heckova; Gilbert Hangel; Stanislav Motyka; Siegfried Trattnig; Bernhard Strasser
Journal:  Magn Reson Med       Date:  2019-06-10       Impact factor: 4.668

6.  Intra-session and inter-subject variability of 3D-FID-MRSI using single-echo volumetric EPI navigators at 3T.

Authors:  Philipp Moser; Korbinian Eckstein; Lukas Hingerl; Michael Weber; Stanislav Motyka; Bernhard Strasser; Andre van der Kouwe; Simon Robinson; Siegfried Trattnig; Wolfgang Bogner
Journal:  Magn Reson Med       Date:  2019-11-13       Impact factor: 4.668

7.  Effects of SSRI treatment on GABA and glutamate levels in an associative relearning paradigm.

Authors:  B Spurny; T Vanicek; R Seiger; M B Reed; M Klöbl; V Ritter; J Unterholzner; G M Godbersen; L R Silberbauer; D Pacher; S Klug; M E Konadu; G Gryglewski; S Trattnig; W Bogner; R Lanzenberger
Journal:  Neuroimage       Date:  2021-02-28       Impact factor: 7.400

8.  Motion correction methods for MRS: experts' consensus recommendations.

Authors:  Ovidiu C Andronesi; Pallab K Bhattacharyya; Wolfgang Bogner; In-Young Choi; Aaron T Hess; Phil Lee; Ernesta M Meintjes; M Dylan Tisdall; Maxim Zaitzev; André van der Kouwe
Journal:  NMR Biomed       Date:  2020-07-20       Impact factor: 4.044

Review 9.  Accelerated MR spectroscopic imaging-a review of current and emerging techniques.

Authors:  Wolfgang Bogner; Ricardo Otazo; Anke Henning
Journal:  NMR Biomed       Date:  2020-05-12       Impact factor: 4.044

10.  Real-time motion and retrospective coil sensitivity correction for CEST using volumetric navigators (vNavs) at 7T.

Authors:  Esau Poblador Rodriguez; Philipp Moser; Sami Auno; Korbinian Eckstein; Barbara Dymerska; Andre van der Kouwe; Stephan Gruber; Siegfried Trattnig; Wolfgang Bogner
Journal:  Magn Reson Med       Date:  2020-11-09       Impact factor: 3.737