Restoration of motion-related signal loss and line-shape deterioration of proton MR spectra using the residual water as intrinsic reference.

G Helms1, A Piringer.   

Abstract

A postprocessing method to restore motion-related signal loss and line-shape deterioration in single-volume proton MR spectroscopy (MRS) is presented. Each acquisition is corrected by its phase offset and frequency shift, extracted from the residual water signal prior to averaging. Requirements are good gradient selection and selective suppression of CSF in residual water. Stimulated echo acquisition mode (STEAM) spectra (TE = 30 ms) were analyzed using the LCModel program to study gains in metabolite signal and spectral quality in five brain regions. Increases of total N-acetyl-aspartate concentrations of up to 5% were observed. The method may be beneficial for clinical examinations of less compliant subjects and for dynamic spectroscopy.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11477645     DOI: 10.1002/mrm.1203

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  T2-based segmentation of periventricular paragraph sign volumes for quantification of proton magnetic paragraph sign resonance spectra of multiple sclerosis lesions.

Authors:  Gunther Helms
Journal:  MAGMA       Date:  2003-02       Impact factor: 2.310

2.  On restoring motion-induced signal loss in single-voxel magnetic resonance spectra.

Authors:  Refaat E Gabr; Shashank Sathyanarayana; Michael Schär; Robert G Weiss; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

3.  A novel phase and frequency navigator for proton magnetic resonance spectroscopy using water-suppression cycling.

Authors:  Thomas Ernst; Jikun Li
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

Review 4.  Metabolite quantification and high-field MRS in breast cancer.

Authors:  Ihab S Haddadin; Adeka McIntosh; Sina Meisamy; Curt Corum; Angela L Styczynski Snyder; Nathaniel J Powell; Michael T Nelson; Douglas Yee; Michael Garwood; Patrick J Bolan
Journal:  NMR Biomed       Date:  2009-01       Impact factor: 4.044

5.  Impact of frequency drift on gamma-aminobutyric acid-edited MR spectroscopy.

Authors:  Ashley D Harris; Benjamin Glaubitz; Jamie Near; C John Evans; Nicolaas A J Puts; Tobias Schmidt-Wilcke; Martin Tegenthoff; Peter B Barker; Richard A E Edden
Journal:  Magn Reson Med       Date:  2013-11-11       Impact factor: 4.668

6.  Dynamic metabolic changes in human visual cortex in regions with positive and negative blood oxygenation level-dependent response.

Authors:  Miguel Martínez-Maestro; Christian Labadie; Harald E Möller
Journal:  J Cereb Blood Flow Metab       Date:  2018-08-17       Impact factor: 6.200

7.  Frequency and phase correction for multiplexed edited MRS of GABA and glutathione.

Authors:  Mark Mikkelsen; Muhammad G Saleh; Jamie Near; Kimberly L Chan; Tao Gong; Ashley D Harris; Georg Oeltzschner; Nicolaas A J Puts; Kim M Cecil; Iain D Wilkinson; Richard A E Edden
Journal:  Magn Reson Med       Date:  2017-12-07       Impact factor: 4.668

8.  Prospective frequency correction using outer volume suppression-localized navigator for MR spectroscopy and spectroscopic imaging.

Authors:  Chu-Yu Lee; In-Young Choi; Phil Lee
Journal:  Magn Reson Med       Date:  2018-05-13       Impact factor: 4.668

9.  Respiratory motion-corrected proton magnetic resonance spectroscopy of the liver.

Authors:  Susan M Noworolski; Phyllis C Tien; Raphael Merriman; Daniel B Vigneron; Aliya Qayyum
Journal:  Magn Reson Imaging       Date:  2008-11-06       Impact factor: 2.546

10.  Increased thalamus levels of glutamate and glutamine (Glx) in patients with idiopathic generalised epilepsy.

Authors:  G Helms; C Ciumas; S Kyaga; I Savic
Journal:  J Neurol Neurosurg Psychiatry       Date:  2006-04       Impact factor: 10.154

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.