Literature DB >> 1734171

Inhomogeneity correction for in vivo spectroscopy by high-resolution water referencing.

P Webb1, D Spielman, A Macovski.   

Abstract

One of the most common sources of distortion in in vivo spectroscopy is the inhomogeneity of the main magnetic field. This effect is particularly problematic when performing spectroscopic imaging, as the shim cannot be simultaneously optimized for all voxels. In this paper we present a technique to measure inhomogeneity rapidly, then show how to use the measurement to improve the analysis of the spectrum. This technique can be applied in conjunction with any spectroscopic localization method and any spectral quantitation algorithm. We present results from spectroscopic imaging of phantoms, then show application to a single-voxel water-suppressed proton brain study. We find that the quantitation of the in vivo spectrum is made immune to inhomogeneous line broadening.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1734171     DOI: 10.1002/mrm.1910230102

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Natural linewidth chemical shift imaging (NL-CSI).

Authors:  Adil Bashir; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

2.  1H-spectroscopic imaging with read gradient during acquisition in inhomogeneous fields: analysis, measurement strategy, and data processing.

Authors:  J Weis; A Ericsson; A Hemmingsson
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

3.  Chemical exchange saturation transfer magnetic resonance imaging of human knee cartilage at 3 T and 7 T.

Authors:  Anup Singh; Mohammad Haris; Kejia Cai; Victor B Kassey; Feliks Kogan; Damodar Reddy; Hari Hariharan; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2011-12-27       Impact factor: 4.668

4.  Role of very high order and degree B0 shimming for spectroscopic imaging of the human brain at 7 tesla.

Authors:  Jullie W Pan; Kai-Ming Lo; Hoby P Hetherington
Journal:  Magn Reson Med       Date:  2011-12-28       Impact factor: 4.668

5.  High-throughput screening of chemical exchange saturation transfer MR contrast agents.

Authors:  Guanshu Liu; Assaf A Gilad; Jeff W M Bulte; Peter C M van Zijl; Michael T McMahon
Journal:  Contrast Media Mol Imaging       Date:  2010 May-Jun       Impact factor: 3.161

6.  Real-time motion and B0 corrected single voxel spectroscopy using volumetric navigators.

Authors:  Aaron T Hess; M Dylan Tisdall; Ovidiu C Andronesi; Ernesta M Meintjes; André J W van der Kouwe
Journal:  Magn Reson Med       Date:  2011-03-04       Impact factor: 4.668

7.  Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments.

Authors:  Mina Kim; Joseph Gillen; Bennett A Landman; Jinyuan Zhou; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

8.  Spectral resolution amelioration by deconvolution (SPREAD) in MR spectroscopic imaging.

Authors:  Zhengchao Dong; Bradley S Peterson
Journal:  J Magn Reson Imaging       Date:  2009-06       Impact factor: 4.813

9.  Improved calibration technique for in vivo proton MRS thermometry for brain temperature measurement.

Authors:  M Zhu; A Bashir; J J Ackerman; D A Yablonskiy
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.