Limits of Ultra-Low Dose CT Attenuation Correction for PET/CT.

Ting Xia1, Adam M Alessio, Paul E Kinahan.   

Abstract

We present an analysis of the effects of ultra-low dose X-ray computerized tomography (CT) based attenuation correction for positron emission tomography (PET). By ultra low dose we mean less than approximately 5 mAs or 0.5 mSv total effective whole body dose. The motivation is the increased interest in using respiratory motion information acquired during the CT scan for both phase-matched CT-based attenuation correction and for motion estimation. Since longer duration CT scans are desired, radiation dose to the patient can be a limiting factor. In this study we evaluate the impact of reducing photon flux rates in the CT data on the reconstructed PET image by using the CATSIM simulation tool for the CT component and the ASIM simulation tool for the PET component. The CT simulation includes effects of the x-ray tube spectra, beam conditioning, bowtie filter, detector noise, and bean hardening correction. The PET simulation includes the effect of attenuation and photon counting. Noise and bias in the PET image were evaluated from multiple realizations of test objects. We show that techniques can be used to significantly reduce the mAs needed for CT based attenuation correction if the CT is not used for diagnostic purposes. The limiting factor, however, is not the noise in the CT image but rather the bias introduced by CT sinogram elements with no detected flux. These results constrain the methods that can be used to lower CT dose in a manner suitable for attenuation correction of PET data. We conclude that ultra-low-dose CT for attenuation correction of PET data is feasible with current PET/CT scanners.

Entities:  

Year:  2010        PMID: 21373372      PMCID: PMC3046413          DOI: 10.1109/NSSMIC.2009.5401665

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  14 in total

1.  An iterative maximum-likelihood polychromatic algorithm for CT.

Authors:  B De Man; J Nuyts; P Dupont; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  2001-10       Impact factor: 10.048

2.  Multi-detector row CT: radiation dose characteristics.

Authors:  Leena M Hamberg; James T Rhea; George J Hunter; James H Thrall
Journal:  Radiology       Date:  2003-03       Impact factor: 11.105

Review 3.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

Authors:  Paul E Kinahan; Bruce H Hasegawa; Thomas Beyer
Journal:  Semin Nucl Med       Date:  2003-07       Impact factor: 4.446

Review 4.  Perfusion CT for the assessment of tumour vascularity: which protocol?

Authors:  K A Miles
Journal:  Br J Radiol       Date:  2003       Impact factor: 3.039

5.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

6.  Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography.

Authors:  D J Crotty; R L McKinley; M P Tornai
Journal:  Phys Med Biol       Date:  2007-01-10       Impact factor: 3.609

Review 7.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

8.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.

Authors:  Guang-Hong Chen; Jie Tang; Shuai Leng
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

9.  Dual energy CT attenuation correction methods for quantitative assessment of response to cancer therapy with PET/CT imaging.

Authors:  Paul E Kinahan; Adam M Alessio; Jeffery A Fessler
Journal:  Technol Cancer Res Treat       Date:  2006-08

10.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

Authors:  C Burger; G Goerres; S Schoenes; A Buck; A H R Lonn; G K Von Schulthess
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-04-19       Impact factor: 9.236

View more
  3 in total

1.  Dual energy CT for attenuation correction with PET/CT.

Authors:  Ting Xia; Adam M Alessio; Paul E Kinahan
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

2.  Ultra-low dose CT attenuation correction for PET/CT.

Authors:  Ting Xia; Adam M Alessio; Bruno De Man; Ravindra Manjeshwar; Evren Asma; Paul E Kinahan
Journal:  Phys Med Biol       Date:  2011-12-09       Impact factor: 3.609

3.  Data-driven gated CT: An automated respiratory gating method to enable data-driven gated PET/CT.

Authors:  Tinsu Pan; M Allan Thomas; Dershan Luo
Journal:  Med Phys       Date:  2022-04-22       Impact factor: 4.506

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.