Literature DB >> 2137048

Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography.

S E Nissen1, C L Grines, J C Gurley, K Sublett, D Haynie, C Diaz, D C Booth, A N DeMaria.   

Abstract

Tomographic imaging techniques such as ultrasound can provide important information in the evaluation of vascular anatomy. Recent technical advances have permitted fabrication of a small (1.83 mm), phased-array, intravascular ultrasonic imaging catheter capable of continuous real-time, cross-sectional imaging of blood vessels. We used this imaging catheter to compare intraluminal ultrasound with cineangiography in the measurement of vascular dimensions in animals and to assess the intraobserver and interobserver variability of the technique. Segmental deformation of vessel anatomy was produced by stenoses created with a tissue ligature or by balloon dilation. The mean value for measurements of vessel diameter was 5.6 mm by cineangiography and 5.7 mm by intravascular ultrasound. The correlation between cineangiography and ultrasound was close (r = 0.98). Mean cross-sectional area by angiography was 28.8 mm2 and 29.6 mm2 (r = 0.96) by ultrasound. Percent diameter reduction produced by the stenoses averaged 48.4% by cineangiography and 40.1% by ultrasound, and the two methods correlated closely (r = 0.89). Correlation between cineangiography and ultrasound for vessel diameter and area before balloon dilation was closer (r = 0.92 and 0.88) than after balloon dilation (r = 0.86 and 0.81). This difference reflected an increase in measured vessel eccentricity following balloon dilation. These data demonstrate that intravascular ultrasound is an accurate and reproducible method for measurement of vascular diameter and cross-sectional area in vivo. Intravascular ultrasound is capable of accurately identifying and quantifying segmental deformation of vascular dimensions produced by either stenoses or balloon dilation.

Entities:  

Mesh:

Year:  1990        PMID: 2137048     DOI: 10.1161/01.cir.81.2.660

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  28 in total

1.  Assessment of the mechanical properties of coronary arteries using intravascular ultrasound: an in vivo study.

Authors:  M J Williams; R A Stewart; C J Low; G T Wilkins
Journal:  Int J Card Imaging       Date:  1999-08

2.  Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations--animal and clinical studies in stented and non-stented coronary arteries.

Authors:  J C Tardif; O F Bertrand; R Mongrain; J Lespérance; J Grégoire; P Paiement; R Bonan
Journal:  Int J Card Imaging       Date:  2000-10

3.  Intravascular ultrasound imaging of the coronary arteries: an in vitro evaluation of measurement of area of the lumen and atheroma characterisation.

Authors:  M H Anderson; I A Simpson; D Katritsis; M J Davies; D E Ward
Journal:  Br Heart J       Date:  1992-09

4.  Adjustment method for mechanical Boston scientific corporation 30 MHz intravascular ultrasound catheters connected to a Clearview console. Mechanical 30 MHz IVUS catheter adjustment.

Authors:  Nico Bruining; Ronald Hamers; Tat-Jin Teo; Pim J de Feijter; Patrick W Serruys; Jos R T C Roelandt
Journal:  Int J Cardiovasc Imaging       Date:  2004-04       Impact factor: 2.357

5.  Impact of surrounding tissue on conductance measurement of coronary and peripheral lumen area.

Authors:  Hyo Won Choi; Benjamin Jansen; Zhen-Du Zhang; Ghassan S Kassab
Journal:  J R Soc Interface       Date:  2012-06-20       Impact factor: 4.118

6.  Atherosclerosis imaging with intravascular ultrasound. Validating acquisition and measurement tools to assure meaningful results.

Authors:  Paul Schoenhagen
Journal:  Int J Cardiovasc Imaging       Date:  2006-10       Impact factor: 2.357

7.  Intracardiac echocardiography: current developments.

Authors:  N G Pandian; S L Schwartz; A R Weintraub; T L Hsu; M A Konstam; D N Salem
Journal:  Int J Card Imaging       Date:  1991

8.  Improvement of coronary morphology and blood flow after stenting. Assessment by intravascular ultrasound and intracoronary Doppler.

Authors:  J Ge; R Erbel; J Zamorano; M Haude; P Kearney; G Görge; J Meyer
Journal:  Int J Card Imaging       Date:  1995-06

9.  Quantitative assessment of peripheral and coronary artery lesions before and after balloon angioplasty: a comparison of intravascular ultrasound and angiography.

Authors:  M Schartl; W Bocksch; T Linderer; S Beckmann; S Dreysse
Journal:  Heart Vessels       Date:  1994       Impact factor: 2.037

10.  Intravascular ultrasonography of supra-aortic arteries as an adjunct to percutaneous transluminal angioplasty.

Authors:  T Hirai; Y Korogi; Y Sakamoto; S Hamatake; M Takahashi
Journal:  Neuroradiology       Date:  1995-07       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.