Literature DB >> 7961298

Quantitative assessment of peripheral and coronary artery lesions before and after balloon angioplasty: a comparison of intravascular ultrasound and angiography.

M Schartl1, W Bocksch, T Linderer, S Beckmann, S Dreysse.   

Abstract

Intravascular ultrasound and conventional angiography were used to determine the degree of stenosis before and after angioplasty in 25 consecutive patients with peripheral arterial occlusive disease and 15 selected patients with coronary artery disease. Angiographic determinations of the luminal area and percent stenosis were made with the help of an automatic detection system, and the same parameters were evaluated planimetrically in the ultrasound studies. Following angioplasty of peripheral lesions, angiography demonstrated a significantly greater increase in mean luminal area (10.8 +/- 7.8 mm2 vs 5.8 +/- 4.0 mm2; P < 0.05) and a greater reduction in degree of stenosis (26% +/- 16% vs 14% +/- 11%; P < 0.05) than did the ultrasonic investigation. There was a significant but moderate correlation between values for the luminal area determined by angiography and ultrasound before angioplasty (r = 0.75; SEE = 4.8 mm2) and in normal proximal segments of coronary arteries (r = 0.79; SEE 4.1 mm2). Following angioplasty there was no significant correlation between angiographic findings and those determined by intravascular ultrasound in peripheral or coronary lesions. These results suggest that angiography and intravascular ultrasound are fundamentally different imaging and analysis techniques. Following angioplasty, conventional angiography rarely demonstrated dissection or intraluminal filling defects, while intravascular ultrasound detected plaque rupture and the presence of intraluminal atheroma in almost all cases. Quantitative determinations of luminal area and degree of stenosis rely on indirect measures with conventional angiography, while these parameters are determined directly by intravascular ultrasound.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7961298     DOI: 10.1007/BF01746065

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  31 in total

1.  Intravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro.

Authors:  J M Tobis; J A Mallery; J Gessert; J Griffith; D Mahon; M Bessen; M Moriuchi; L McLeay; M McRae; W L Henry
Journal:  Circulation       Date:  1989-10       Impact factor: 29.690

2.  Comparison by quantitative angiographic assessment of coronary stenoses of one view showing the severest narrowing to two orthogonal views.

Authors:  J Lesperance; G Hudon; C W White; J Laurier; D Waters
Journal:  Am J Cardiol       Date:  1989-09-01       Impact factor: 2.778

3.  Intracoronary ultrasound evaluation of interventional technologies.

Authors:  C J Davidson; K H Sheikh; K B Kisslo; H R Phillips; R H Peter; V S Behar; Y H Kong; M Krucoff; E M Ohman; J E Tcheng
Journal:  Am J Cardiol       Date:  1991-11-15       Impact factor: 2.778

4.  Intravascular ultrasound estimation of arterial stenosis.

Authors:  N G Pandian; A Kreis; T O'Donnell
Journal:  J Am Soc Echocardiogr       Date:  1989 Nov-Dec       Impact factor: 5.251

5.  Intravascular ultrasonography versus digital subtraction angiography: a human in vivo comparison of vessel size and morphology.

Authors:  C J Davidson; K H Sheikh; J K Harrison; S I Himmelstein; M E Leithe; K B Kisslo; T M Bashore
Journal:  J Am Coll Cardiol       Date:  1990-09       Impact factor: 24.094

6.  Coronary artery imaging with intravascular high-frequency ultrasound.

Authors:  B N Potkin; A L Bartorelli; J M Gessert; R F Neville; Y Almagor; W C Roberts; M B Leon
Journal:  Circulation       Date:  1990-05       Impact factor: 29.690

7.  [Intravascular ultrasonic diagnosis. In vivo findings before and after angioplasty in peripheral arterial occlusive disease].

Authors:  G S Werner; D Corovic; A Buchwald; G Sold; H Kreuzer; V Wiegand
Journal:  Dtsch Med Wochenschr       Date:  1990-08-24       Impact factor: 0.628

8.  Morphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging.

Authors:  J Honye; D J Mahon; A Jain; C J White; S R Ramee; J B Wallis; A al-Zarka; J M Tobis
Journal:  Circulation       Date:  1992-03       Impact factor: 29.690

9.  How does angioplasty work? Serial analysis of human iliac arteries using intravascular ultrasound.

Authors:  D W Losordo; K Rosenfield; A Pieczek; K Baker; M Harding; J M Isner
Journal:  Circulation       Date:  1992-12       Impact factor: 29.690

10.  Imaging artifacts in mechanically driven ultrasound catheters.

Authors:  H ten Hoff; A Korbijn; T H Smith; J F Klinkhamer; N Bom
Journal:  Int J Card Imaging       Date:  1989
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.