Literature DB >> 10517378

Assessment of the mechanical properties of coronary arteries using intravascular ultrasound: an in vivo study.

M J Williams1, R A Stewart, C J Low, G T Wilkins.   

Abstract

The pressure-area relation of coronary arteries provides important information about the mechanical properties of these vessels. In human subjects methodological limitations have precluded measurement of instantaneous compliance and coronary stress in vivo. The purpose of this study was to assess a new method for measuring instantaneous values of coronary artery compliance and wall stress utilizing simultaneously acquired pressure and intravascular ultrasound measurements of vessel area. Ten subjects with coronary artery disease had intravascular ultrasound studies of the proximal left anterior descending or circumflex coronary arteries. Coronary luminal area was measured with a 30-MHz (3F or 3.5F) intravascular ultrasound catheter and simultaneous coronary pressure measured with a 2F micromanometer-tipped catheter. Using this technique the nonlinear pressure-area relation and mean circumferential wall stress were determined over the physiological pressure range. Coronary artery compliance at 100 mmHg ranged from 0.010 to 0.052 mm2/mmHg (mean +/- SD, 0.020+/-0.012 mm2/mmHg). Peak systolic circumferential stress ranged from 0.52 to 2.03 x 10(6) dyn/cm2 (1.09+/-0.42 x 10(6) dyn/cm2). This study describes a new method of determining coronary artery mechanical properties over the physiological pressure range. This technique may be useful in further studies of coronary artery mechanics.

Entities:  

Mesh:

Year:  1999        PMID: 10517378     DOI: 10.1023/a:1006279228534

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  35 in total

1.  Geometric accuracy of intravascular ultrasound imaging.

Authors:  J S Chae; A F Brisken; G Maurer; R J Siegel
Journal:  J Am Soc Echocardiogr       Date:  1992 Nov-Dec       Impact factor: 5.251

2.  Clinical percutaneous imaging of coronary anatomy using an over-the-wire ultrasound catheter system.

Authors:  J M Hodgson; S P Graham; A D Savakus; S G Dame; D N Stephens; P S Dhillon; D Brands; H Sheehan; M J Eberle
Journal:  Int J Card Imaging       Date:  1989

3.  In vivo viscoelastic behavior in the human aorta.

Authors:  T Imura; K Yamamoto; T Satoh; K Kanamori; T Mikami; H Yasuda
Journal:  Circ Res       Date:  1990-05       Impact factor: 17.367

4.  Intravascular ultrasonic evidence for importance of plaque distribution (eccentric vs circumferential) in determining distensibility of the left anterior descending artery.

Authors:  M Yamagishi; T Umeno; Y Hongo; H Tsutsui; Y Goto; S Nakatani; K Miyatake
Journal:  Am J Cardiol       Date:  1997-06-15       Impact factor: 2.778

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Coronary artery imaging with intravascular high-frequency ultrasound.

Authors:  B N Potkin; A L Bartorelli; J M Gessert; R F Neville; Y Almagor; W C Roberts; M B Leon
Journal:  Circulation       Date:  1990-05       Impact factor: 29.690

7.  High stress regions in saphenous vein bypass graft atherosclerotic lesions.

Authors:  R T Lee; H M Loree; M C Fishbein
Journal:  J Am Coll Cardiol       Date:  1994-12       Impact factor: 24.094

8.  Distensibility of the ascending aorta: comparison of invasive and non-invasive techniques in healthy men and in men with coronary artery disease.

Authors:  C Stefanadis; C Stratos; H Boudoulas; C Kourouklis; P Toutouzas
Journal:  Eur Heart J       Date:  1990-11       Impact factor: 29.983

9.  Clinical assessment of elastic properties of large coronary arteries: pressure-diameter relationship and dynamic incremental elastic modulus.

Authors:  T Shimazu; M Hori; M Mishima; A Kitabatake; K Kodama; S Nanto; M Inoue
Journal:  Int J Cardiol       Date:  1986-10       Impact factor: 4.164

10.  Effects of fibrous cap thickness on peak circumferential stress in model atherosclerotic vessels.

Authors:  H M Loree; R D Kamm; R G Stringfellow; R T Lee
Journal:  Circ Res       Date:  1992-10       Impact factor: 17.367

View more
  4 in total

1.  Randomised comparison of the effects of nicardipine and esmolol on coronary artery wall stress: implications for the risk of plaque rupture.

Authors:  M J Williams; C J Low; G T Wilkins; R A Stewart
Journal:  Heart       Date:  2000-10       Impact factor: 5.994

2.  Effect of stenosis eccentricity on the functionality of coronary bifurcation lesions-a numerical study.

Authors:  Catherine Pagiatakis; Jean-Claude Tardif; Philippe L L'Allier; Rosaire Mongrain
Journal:  Med Biol Eng Comput       Date:  2017-05-13       Impact factor: 2.602

3.  Comparisons of planar and tubular biaxial tensile testing protocols of the same porcine coronary arteries.

Authors:  Joseph T Keyes; Danielle R Lockwood; Urs Utzinger; Leonardo G Montilla; Russell S Witte; Jonathan P Vande Geest
Journal:  Ann Biomed Eng       Date:  2012-11-07       Impact factor: 3.934

Review 4.  The rationale and emergence of electroconductive biomaterial scaffolds in cardiac tissue engineering.

Authors:  Matteo Solazzo; Fergal J O'Brien; Valeria Nicolosi; Michael G Monaghan
Journal:  APL Bioeng       Date:  2019-10-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.