Literature DB >> 21343318

Characterisation of dose distribution in linear accelerator-based intracranial stereotactic radiosurgery with the dynamic conformal arc technique: consideration of the optimal method for dose prescription and evaluation.

K Ohtakara1, S Hayashi, H Hoshi.   

Abstract

OBJECTIVES: The purpose of this study was to characterise dose distribution in linear accelerator-based intracranial stereotactic radiosurgery using the dynamic conformal arc technique, and to validate the pertinence of dose prescription to the specific percentage isodose surface (IDS).
METHODS: 73 plans for brain metastases were reviewed and replanned with a uniform method for target definition and treatment planning.
RESULTS: In all cases except 1 the dose prescription to the 80% IDS satisfied the criteria of the standardised prescription IDS as previously proposed. However, both of the planning target volume (PTV) coverage values for the 80% and 90% IDSs and the PTV D99 and D95 (IDS receiving at least 99% or 95% of the PTV) were inconsistent and significantly increased as a function of the PTV size. The 80% IDS for a PTV of more than 5 cm(3) achieved adequate PTV coverage without a leaf margin. The dose conformity for 80% IDS gradually worsened as the PTV increased, whereas that for the PTV D99 or D95 improved as a function of the PTV size. The addition of a leaf margin attained 100% PTV coverage for 80% IDS, while leading to a poorer dose conformity.
CONCLUSION: The dose prescription to the specific percentage IDS does not necessarily guarantee consistent target coverage, D99 and D95, and desirable dose conformity in proportion to the target volume. The dose prescription and evaluation at the specific target coverage would therefore be preferable as an objective method in order to report the "marginal dose" and to clearly compare the planning parameters with those from other modalities.

Entities:  

Mesh:

Year:  2011        PMID: 21343318      PMCID: PMC3473924          DOI: 10.1259/bjr/20905396

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  18 in total

1.  Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery.

Authors:  V P Cosgrove; U Jahn; M Pfaender; S Bauer; V Budach; R E Wurm
Journal:  Radiother Oncol       Date:  1999-03       Impact factor: 6.280

2.  Dosimetric characteristics of Novalis shaped beam surgery unit.

Authors:  Fang-Fang Yin; Jingeng Zhu; Hui Yan; Haiqun Gaun; Rabih Hammoud; Samuel Ryu; Jae H Kim
Journal:  Med Phys       Date:  2002-08       Impact factor: 4.071

3.  Phase II trial of hypofractionated stereotactic radiotherapy for brain metastases: results and toxicity.

Authors:  Antje Ernst-Stecken; Oliver Ganslandt; Ulrike Lambrecht; Rolf Sauer; Gerhard Grabenbauer
Journal:  Radiother Oncol       Date:  2006-09-15       Impact factor: 6.280

4.  Dosimetric study using different leaf-width MLCs for treatment planning of dynamic conformal arcs and intensity-modulated radiosurgery.

Authors:  Jian-Yue Jin; Fang-Fang Yin; Samuel Ryu; Munther Ajlouni; Jae Ho Kim
Journal:  Med Phys       Date:  2005-02       Impact factor: 4.071

Review 5.  Conformity index: a review.

Authors:  Loïc Feuvret; Georges Noël; Jean-Jacques Mazeron; Pierre Bey
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-02-01       Impact factor: 7.038

6.  Dosimetric and radiobiological evaluation of dose distribution perturbation due to head heterogeneities for Linac and Gamma Knife stereotactic radiotherapy.

Authors:  Kiki Theodorou; Sotirios Stathakis; Bengt Lind; Constantin Kappas
Journal:  Acta Oncol       Date:  2008       Impact factor: 4.089

7.  Radiation Therapy Oncology Group: radiosurgery quality assurance guidelines.

Authors:  E Shaw; R Kline; M Gillin; L Souhami; A Hirschfeld; R Dinapoli; L Martin
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-12-01       Impact factor: 7.038

8.  Irradiated volume as a predictor of brain radionecrosis after linear accelerator stereotactic radiosurgery.

Authors:  Brian J Blonigen; Ryan D Steinmetz; Linda Levin; Michael A Lamba; Ronald E Warnick; John C Breneman
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-09-23       Impact factor: 7.038

9.  Does intensity modulation improve healthy tissue sparing in stereotactic radiosurgery of complex arteriovenous malformations?

Authors:  Brenda Clark; Michael McKenzie; James Robar; Emily Vollans; Charlie Candish; Brian Toyota; Andrew Lee; Roy Ma; Karen Goddard; Sara Erridge
Journal:  Med Dosim       Date:  2007       Impact factor: 1.482

10.  Radiosurgical planning of meningiomas: compromises with conformity.

Authors:  Jeremy G Rowe; Lee Walton; Paul Vaughan; Irfan Malik; Matthias Radatz; Andras Kemeny
Journal:  Stereotact Funct Neurosurg       Date:  2004-11-10       Impact factor: 1.875

View more
  8 in total

1.  Clinical outcomes of single or oligo-fractionated stereotactic radiotherapy for head and neck tumors using micromultileaf collimator-based dynamic conformal arcs.

Authors:  Kazuhiro Ohtakara; Shinya Hayashi; Keisuke Mizuta; Mitsuhiro Aoki; Kenichi Ando; Sunaho Okada; Yatsuji Ito; Hiroaki Hoshi
Journal:  J Cancer Res Clin Oncol       Date:  2012-04-22       Impact factor: 4.553

2.  Significance of target location relative to the depth from the brain surface and high-dose irradiated volume in the development of brain radionecrosis after micromultileaf collimator-based stereotactic radiosurgery for brain metastases.

Authors:  Kazuhiro Ohtakara; Shinya Hayashi; Noriyuki Nakayama; Naoyuki Ohe; Hirohito Yano; Toru Iwama; Hiroaki Hoshi
Journal:  J Neurooncol       Date:  2012-03-06       Impact factor: 4.130

3.  Consideration of optimal isodose surface selection for target coverage in micro-multileaf collimator-based stereotactic radiotherapy for large cystic brain metastases: comparison of 90%, 80% and 70% isodose surface-based planning.

Authors:  K Ohtakara; S Hayashi; H Tanaka; H Hoshi
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

4.  The relation between various conformity indices and the influence of the target coverage difference in prescription isodose surface on these values in intracranial stereotactic radiosurgery.

Authors:  K Ohtakara; S Hayashi; H Hoshi
Journal:  Br J Radiol       Date:  2011-09-21       Impact factor: 3.039

5.  Cerebral cyst formation following stereotactic ablative irradiation for non-nasopharyngeal head and neck malignancies: imaging findings and relevant dosimetric parameters.

Authors:  K Ohtakara; H Hoshi
Journal:  Br J Radiol       Date:  2014-02-26       Impact factor: 3.039

6.  The effect of setup uncertainty on optimal dosimetric margin in LINAC-based stereotactic radiosurgery with dynamic conformal arc technique.

Authors:  Xiaoyu Duan; William Giles; John P Kirkpatrick; Fang-Fang Yin
Journal:  J Radiosurg SBRT       Date:  2019

7.  Prescription to 50-75% isodose line may be optimum for linear accelerator based radiosurgery of cranial lesions.

Authors:  Bo Zhao; Jian-Yue Jin; Ning Wen; Yimei Huang; M Salim Siddiqui; Indrin J Chetty; Samuel Ryu
Journal:  J Radiosurg SBRT       Date:  2014

8.  Optimal set of grid size and angular increment for practical dose calculation using the dynamic conformal arc technique: a systematic evaluation of the dosimetric effects in lung stereotactic body radiation therapy.

Authors:  Ji-Yeon Park; Siyong Kim; Hae-Jin Park; Jeong-Woo Lee; Yeon-Sil Kim; Tae-Suk Suh
Journal:  Radiat Oncol       Date:  2014-01-04       Impact factor: 3.481

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.