Literature DB >> 12201420

Dosimetric characteristics of Novalis shaped beam surgery unit.

Fang-Fang Yin1, Jingeng Zhu, Hui Yan, Haiqun Gaun, Rabih Hammoud, Samuel Ryu, Jae H Kim.   

Abstract

The dosimetric characteristics of a new dedicated radiosurgical treatment unit are systematically measured in terms of its percent depth dose, beam profile, and relative scatter factor. High-resolution diode detector, mini-ion-chamber detector, and conventional Kodak XV films are used to measure dosimetric data for a range of field sizes from 6x6 mm to 100x100 mm. The effects of collimator size, micro-multileaf collimator shape, and detector type on the dosimetric data are investigated. Results indicate that, with careful design, accurate dosimetric data could be acquired using either a dedicated diode detector or a mini-ion-chamber detector, and film detector. Special attention is required when measuring dosimetric data for small field sizes such as 6x6 mm.

Mesh:

Year:  2002        PMID: 12201420     DOI: 10.1118/1.1494830

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

Review 1.  The evolving role of stereotactic radiosurgery and stereotactic radiation therapy for patients with spine tumors.

Authors:  Jack P Rock; Samuel Ryu; Fang-Fang Yin; Faye Schreiber; Muwaffak Abdulhak
Journal:  J Neurooncol       Date:  2004 Aug-Sep       Impact factor: 4.130

2.  Characterisation of dose distribution in linear accelerator-based intracranial stereotactic radiosurgery with the dynamic conformal arc technique: consideration of the optimal method for dose prescription and evaluation.

Authors:  K Ohtakara; S Hayashi; H Hoshi
Journal:  Br J Radiol       Date:  2011-02-22       Impact factor: 3.039

3.  Radiosurgery technology development and use.

Authors:  Sanford L Meeks; Jason Pukala; Naren Ramakrishna; Twyla R Willoughby; Francis J Bova
Journal:  J Radiosurg SBRT       Date:  2011

4.  Initial results of fractionated CyberKnife radiosurgery for uveal melanoma.

Authors:  Faruk Zorlu; Ugur Selek; Hayyam Kiratli
Journal:  J Neurooncol       Date:  2009-02-22       Impact factor: 4.130

5.  Stereotactic radiosurgery of primary spine and spinal cord tumors.

Authors:  Samuel Ryu; Andrew Biondo; Jack Rock; Marilyn Gates; Muwaffak Abdulhak
Journal:  J Radiosurg SBRT       Date:  2013

6.  Stereotactic radiosurgery for high-grade metastatic epidural cord compression.

Authors:  Ian Lee; Melvin Omodon; Jack Rock; Lonni Shultz; Samuel Ryu
Journal:  J Radiosurg SBRT       Date:  2014

Review 7.  Contemporary treatment with radiosurgery for spine metastasis and spinal cord compression in 2015.

Authors:  Samuel Ryu; Hannah Yoon; Alexander Stessin; Fred Gutman; Arthur Rosiello; Raphael Davis
Journal:  Radiat Oncol J       Date:  2015-03-31

8.  Physical and dosimetric characteristic of high-definition multileaf collimator (HDMLC) for SRS and IMRT.

Authors:  Dayananda Shamurailatpam Sharma; Prabhakar M Dongre; Vaibav Mhatre; Malhotra Heigrujam
Journal:  J Appl Clin Med Phys       Date:  2011-04-14       Impact factor: 2.102

9.  Initial clinical experience with frameless optically guided stereotactic radiosurgery/radiotherapy in pediatric patients.

Authors:  Sassan Keshavarzi; Hal Meltzer; Sharona Ben-Haim; Charles Benjamin Newman; Joshua D Lawson; Michael L Levy; Kevin Murphy
Journal:  Childs Nerv Syst       Date:  2009-03-27       Impact factor: 1.475

10.  Dosimetric verification of micro-MLC based intensity modulated radiation therapy.

Authors:  Parminder Basran; Collins Yeboah
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.