Literature DB >> 17707196

Does intensity modulation improve healthy tissue sparing in stereotactic radiosurgery of complex arteriovenous malformations?

Brenda Clark1, Michael McKenzie, James Robar, Emily Vollans, Charlie Candish, Brian Toyota, Andrew Lee, Roy Ma, Karen Goddard, Sara Erridge.   

Abstract

This planning study evaluates the potential of intensity modulated treatment fields and inverse planning techniques in stereotactic radiosurgery to reduce healthy tissue dose. Twenty patients previously treated with stereotactic radiosurgery for arteriovenous malformation (AVM) were replanned with each of 4 techniques: circular non-coplanar arcs, dynamic arcs, static conformal fields, and intensity modulated radiosurgery (IMRS). Patients were selected having a maximum AVM dimension at least 20 mm, or volume greater than 10 cm(3). Target volumes ranged from 2.12 cm(3) to 13.87 cm(3) with a median of 6.03 cm(3). Resulting dose distributions show a statistically significant improvement in target conformality between circular arcs and all other techniques (p </= 0.001), between conformal and both dynamic arcs and IMRS (p </= 0.03) and with no difference between dynamic arcs and IMRS. However, for AVMs of volume greater than 5.5 cm(3), IMRS gives better conformality than dynamic arcs (p = 0.04). IMRS showed consistently lower dose inhomogeneity compared to both dynamic arcs and conformal fields (p < 0.001). At low dose levels, the dynamic arc technique irradiates less healthy tissue than the other techniques (p </= 0.001). Both dynamic arcs and IMRS provide increased ability to conform to the AVM, with IMRS showing greater ability to control dose at the periphery.

Entities:  

Mesh:

Year:  2007        PMID: 17707196     DOI: 10.1016/j.meddos.2006.12.002

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  2 in total

1.  Characterisation of dose distribution in linear accelerator-based intracranial stereotactic radiosurgery with the dynamic conformal arc technique: consideration of the optimal method for dose prescription and evaluation.

Authors:  K Ohtakara; S Hayashi; H Hoshi
Journal:  Br J Radiol       Date:  2011-02-22       Impact factor: 3.039

2.  Tomotherapy radiosurgery for arteriovenous malformations--current possibilities and future options with helical tomotherapy dynamic jaws?

Authors:  S Krause; S Beck; O Schramm; K Schubert; H Hauswald; A Zabel-du Bois; K Herfarth; J Debus; F Sterzing
Journal:  Technol Cancer Res Treat       Date:  2013-03-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.