Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study.

Benedict Wilmes1, Agamemnon Panayotidis, Dieter Drescher.   

Abstract

Sufficient primary stability is of importance for the survival of orthodontic mini-implants. This means that adequate torque has to be achieved during insertion. However, as moments exceeding the fracture resistance of a mini-implant may result in their fracture, the maximum torque load capacity should be known. In this study, the threshold torque values resulting in the fracture of various mini-implant types and diameters were evaluated. Forty-one different mini-implants with diameters ranging from 1.3 to 2.0 mm (Aarhus screw, Abso Anchor, Ancora, Bone screw, Dual Top, Lomas, MAS, O.S.A.S, Ortho Easy, Spider Screw, and Tomas pin) were inserted in acrylic glass by a robot system. Ten specimens of each mini-implant type were tested. The insertion torque was measured and the maximum torque at the time of mini-implant fracture was evaluated. Significance of the mean value differences was evaluated by Kruskal-Wallis tests. Fracture moments varied depending on the diameter of the mini-implants. The measured values ranged from 108.9 Nmm (MAS 1.3×11 mm) to 640.9 Nmm (Lomas 2.0×11 mm). The differences were highly statistically significant (P<0.001). The risk of mini-implant fracture should be borne in mind at the time of insertion, especially if mini-implants with a small diameter are employed. To minimize the risk of fracture, pre-drilling should be carried out if the mini-implants are to be inserted at a site with a high bone density.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21310766     DOI: 10.1093/ejo/cjq151

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  11 in total

1.  Accuracy of torque-limiting devices used for mini-implant placement--an in vitro study.

Authors:  Alexander Pauls; Manuel Nienkemper; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

2.  Accuracy of torque-limiting devices for mini-implant removal: an in vitro study.

Authors:  A Pauls; M Nienkemper; D Drescher
Journal:  J Orofac Orthop       Date:  2013-05-08       Impact factor: 1.938

3.  Experimental investigation of the fracture torque of orthodontic anchorage screws.

Authors:  Susanne Reimann; Mustafa Ayubi; Fraser McDonald; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-04-20       Impact factor: 1.938

4.  An interview with Benedict Wilmes.

Authors:  Guilherme Thiesen; Marcus Vinícius Neiva Nunes do Rego; Jorge Faber; Ki Beom Kim
Journal:  Dental Press J Orthod       Date:  2016 Nov-Dec

5.  Mini-implant stability at the initial healing period: a clinical pilot study.

Authors:  Manuel Nienkemper; Benedict Wilmes; Alexander Pauls; Dieter Drescher
Journal:  Angle Orthod       Date:  2013-07-24       Impact factor: 2.079

6.  Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque.

Authors:  Višnja Katić; Ervin Kamenar; David Blažević; Stjepan Spalj
Journal:  Korean J Orthod       Date:  2014-07-24       Impact factor: 1.372

7.  Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs).

Authors:  Andrea Scribante; Mona A Montasser; Eman Saad Radwan; Luisa Bernardinelli; Roberto Alcozer; Paola Gandini; Maria Francesca Sfondrini
Journal:  Materials (Basel)       Date:  2018-07-05       Impact factor: 3.623

8.  An in vitro study of factors affecting the primary stability of orthodontic mini-implants.

Authors:  Lindsy Holm; Susan J Cunningham; Aviva Petrie; Richard R J Cousley
Journal:  Angle Orthod       Date:  2012-05-07       Impact factor: 2.079

9.  Effects of insertion angle and implant thread type on the fracture properties of orthodontic mini-implants during insertion.

Authors:  Il-Sik Cho; Tae-Woo Kim; Sug-Joon Ahn; Il-Hyung Yang; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2012-12-10       Impact factor: 2.079

10.  Effectiveness of methods for detaching orthodontic implants likely to fracture upon rotational torque - an animal study.

Authors:  Susumu Nakagaki; Masahiro Iijima; Yoshitaka Yasuda; Keisuke Handa; Toshiyuki Koike; Takashi Saito; Itaru Mizoguchi
Journal:  Clin Exp Dent Res       Date:  2016-02-09