Literature DB >> 21264930

Simple analytical dual-band spectral-spatial RF pulses for B(1) + and susceptibility artifact reduction in gradient echo MRI.

Cungeng Yang1, Weiran Deng, V Andrew Stenger.   

Abstract

Susceptibility artifacts and transmission radio frequency (RF) field (B(1) +) inhomogeneity are major limitations in high-field gradient echo MRI. Previously proposed numerical 2D spectral-spatial RF pulses have been shown to be promising for reducing the through-plane signal loss susceptibility artifact by incorporating a frequency-dependent through-plane phase correction. This method has recently been extended to 4D spectral-spatial RF pulse designs for reducing B(1) + inhomogeneity as well as the signal loss. In this manuscript, we present simple analytical pulse designs for constructing 2D and 4D spectral-spatial RF pulses as an alternative to the numerical approaches. The 2D pulse capable of exciting slices with reduced signal loss and is lipid suppressing. The 4D pulse simultaneously corrects signal loss as well as the B(1) + inhomogeneity from a body coil transmitter. The pulses are demonstrated with simulations and with gradient echo phantom and brain images at 3T using a standard RF body coil. The pulses were observed to work well for multiple slices and several volunteers.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Keywords:  Multi-dimensional RF pulses; and B1+ inhomogeneity; dual-band RF pulse; spectral-spatial RF pulses; susceptibility artifacts

Mesh:

Year:  2010        PMID: 21264930      PMCID: PMC3065027          DOI: 10.1002/mrm.22725

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Three-dimensional tailored RF pulses for the reduction of susceptibility artifacts in T(*)(2)-weighted functional MRI.

Authors:  V A Stenger; F E Boada; D C Noll
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  Reducing inhomogeneity artifacts in functional MRI of human brain activation-thin sections vs gradient compensation.

Authors:  K D Merboldt; J Finsterbusch; J Frahm
Journal:  J Magn Reson       Date:  2000-08       Impact factor: 2.229

3.  RF inhomogeneity compensation in structural brain imaging.

Authors:  R Deichmann; C D Good; R Turner
Journal:  Magn Reson Med       Date:  2002-02       Impact factor: 4.668

4.  Single-shot EPI with signal recovery from the susceptibility-induced losses.

Authors:  A W Song
Journal:  Magn Reson Med       Date:  2001-08       Impact factor: 4.668

5.  Utilization of an intra-oral diamagnetic passive shim in functional MRI of the inferior frontal cortex.

Authors:  James L Wilson; Peter Jezzard
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

6.  Simultaneous spatial and spectral selective excitation.

Authors:  C H Meyer; J M Pauly; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1990-08       Impact factor: 4.668

7.  3-D FLASH imaging using a single surface coil and a new adiabatic pulse, BIR-4.

Authors:  R S Staewen; A J Johnson; B D Ross; T Parrish; H Merkle; M Garwood
Journal:  Invest Radiol       Date:  1990-05       Impact factor: 6.016

8.  The intrinsic signal-to-noise ratio in NMR imaging.

Authors:  W A Edelstein; G H Glover; C J Hardy; R W Redington
Journal:  Magn Reson Med       Date:  1986-08       Impact factor: 4.668

9.  Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model.

Authors:  S Ogawa; R S Menon; D W Tank; S G Kim; H Merkle; J M Ellermann; K Ugurbil
Journal:  Biophys J       Date:  1993-03       Impact factor: 4.033

10.  The influence of the slice-selection gradient on functional MRI of human brain activation.

Authors:  J Frahm; K D Merboldt; W Hänicke
Journal:  J Magn Reson B       Date:  1994-01
View more
  7 in total

1.  Simultaneous multislice spectral-spatial excitations for reduced signal loss susceptibility artifact in BOLD functional MRI.

Authors:  Robert J Anderson; Benedikt A Poser; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2013-12-12       Impact factor: 4.668

2.  Fast joint design method for parallel excitation radiofrequency pulse and gradient waveforms considering off-resonance.

Authors:  Daehyun Yoon; Jeffrey A Fessler; Anna C Gilbert; Douglas C Noll
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

3.  Automated slice-specific simultaneous z-shim method for reducing B1 inhomogeneity and susceptibility-induced signal loss with parallel transmission at 3T.

Authors:  Rainer Schneider; Fernando Boada; Jens Haueisen; Josef Pfeuffer
Journal:  Magn Reson Med       Date:  2014-10-07       Impact factor: 4.668

4.  Validation of radiocarpal joint contact models based on images from a clinical MRI scanner.

Authors:  Joshua E Johnson; Terence E McIff; Phil Lee; E Bruce Toby; Kenneth J Fischer
Journal:  Comput Methods Biomech Biomed Engin       Date:  2012-05-25       Impact factor: 1.763

5.  Spectral decomposition of susceptibility artifacts for spectral-spatial radiofrequency pulse design.

Authors:  Cungeng Yang; Benedikt A Poser; Weiran Deng; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2012-02-14       Impact factor: 4.668

6.  Fast and tissue-optimized mapping of magnetic susceptibility and T2* with multi-echo and multi-shot spirals.

Authors:  Bing Wu; Wei Li; Alexandru Vlad Avram; Sung-Min Gho; Chunlei Liu
Journal:  Neuroimage       Date:  2011-07-19       Impact factor: 6.556

7.  Simultaneous Multiple Resonance Frequency imaging (SMURF): Fat-water imaging using multi-band principles.

Authors:  Beata Bachrata; Bernhard Strasser; Wolfgang Bogner; Albrecht Ingo Schmid; Radim Korinek; Martin Krššák; Siegfried Trattnig; Simon Daniel Robinson
Journal:  Magn Reson Med       Date:  2020-09-27       Impact factor: 4.668

  7 in total