Literature DB >> 2345088

3-D FLASH imaging using a single surface coil and a new adiabatic pulse, BIR-4.

R S Staewen1, A J Johnson, B D Ross, T Parrish, H Merkle, M Garwood.   

Abstract

A new adiabatic pulse, which can induce uniform and arbitrary flip angles despite the presence of transmitter coil magnetic field (B1) inhomogeneities, is employed for 3-D fast imaging using a single surface coil for pulse transmission and signal detection. Computer calculations and phantom, rat, and human surface coil imaging experiments demonstrate the utility of this adiabatic pulse for T1-weighted imaging with a transmitter coil which generates a highly inhomogeneous B1 field profile.

Entities:  

Mesh:

Year:  1990        PMID: 2345088     DOI: 10.1097/00004424-199005000-00015

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  36 in total

1.  Adiabatic TOCSY for C,C and H,H J-transfer.

Authors:  W Peti; C Griesinger; W Bermel
Journal:  J Biomol NMR       Date:  2000-11       Impact factor: 2.835

2.  Composite RF pulses for B1+-insensitive volume excitation at 7 Tesla.

Authors:  Jay Moore; Marcin Jankiewicz; Huairen Zeng; Adam W Anderson; John C Gore
Journal:  J Magn Reson       Date:  2010-04-10       Impact factor: 2.229

3.  Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.

Authors:  Suwit Saekho; Fernando E Boada; Douglas C Noll; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

4.  Reduction of transmitter B1 inhomogeneity with transmit SENSE slice-select pulses.

Authors:  Zhenghui Zhang; Chun-Yu Yip; William Grissom; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

5.  Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity.

Authors:  Suwit Saekho; Chun-yu Yip; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

6.  Hyperpolarization without persistent radicals for in vivo real-time metabolic imaging.

Authors:  Tim R Eichhorn; Yuhei Takado; Najat Salameh; Andrea Capozzi; Tian Cheng; Jean-Noël Hyacinthe; Mor Mishkovsky; Christophe Roussel; Arnaud Comment
Journal:  Proc Natl Acad Sci U S A       Date:  2013-10-21       Impact factor: 11.205

7.  Image homogenization using pre-emphasis method for high field MRI.

Authors:  Ye Li; Chunsheng Wang; Baiying Yu; Daniel Vigneron; Wei Chen; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2013-08

8.  Fast slice-selective radio-frequency excitation pulses for mitigating B+1 inhomogeneity in the human brain at 7 Tesla.

Authors:  Adam C Zelinski; Lawrence L Wald; Kawin Setsompop; Vijayanand Alagappan; Borjan A Gagoski; Vivek K Goyal; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

9.  Brain high-energy phosphates and creatine kinase synthesis rate under graded isoflurane anesthesia: An in vivo (31) P magnetization transfer study at 11.7 tesla.

Authors:  Andrew Bresnen; Timothy Q Duong
Journal:  Magn Reson Med       Date:  2014-02-12       Impact factor: 4.668

10.  Hybrid adiabatic-rectangular pulse train for effective saturation of magnetization within the whole heart at 3 T.

Authors:  Daniel Kim; Niels Oesingmann; Kellyanne McGorty
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.