PURPOSE: Simultaneous multislice (SMS) imaging can significantly increase image acquisition rates and improve temporal resolution and contrast in gradient-echo blood oxygen level-dependent (BOLD) functional MRI (fMRI) experiments. Through-plane signal loss due to B(0) inhomogeneities at air-tissue interfaces limits fMRI of structures near the nasal cavity and ear canals. This study implemented spectral-spatial (SPSP) radiofrequency pulses for reduced through-plane signal loss across multiple simultaneously excited slices. THEORY AND METHODS: Multiband (MB) and power independent of number of slices (PINS) methods are combined with SPSP excitation for signal loss compensation in slice-accelerated human brain imaging. Nine simultaneous slices of 5-mm thickness and 20 mm apart were excited using standard MB radiofrequency pulses and the proposed SPSP-SMS pulses, yielding coverage of 36 slices in four shots with 350-ms volume pulse repetition time. The pulses were compared in breath-hold fMRI at 3T. RESULTS: The SPSP-SMS pulses recovered ∼45% of voxels with signal loss in standard SMS images. Activation in areas of signal recovery increased by 26.4% using a 12.6-ms SPSP-MB pulse and 20.3% using a 12.1-ms SPSP-PINS pulse. CONCLUSIONS: It is demonstrated that SPSP-SMS pulses can improve BOLD sensitivity in areas of signal loss across simultaneous multiple slices.
PURPOSE: Simultaneous multislice (SMS) imaging can significantly increase image acquisition rates and improve temporal resolution and contrast in gradient-echo blood oxygen level-dependent (BOLD) functional MRI (fMRI) experiments. Through-plane signal loss due to B(0) inhomogeneities at air-tissue interfaces limits fMRI of structures near the nasal cavity and ear canals. This study implemented spectral-spatial (SPSP) radiofrequency pulses for reduced through-plane signal loss across multiple simultaneously excited slices. THEORY AND METHODS: Multiband (MB) and power independent of number of slices (PINS) methods are combined with SPSP excitation for signal loss compensation in slice-accelerated human brain imaging. Nine simultaneous slices of 5-mm thickness and 20 mm apart were excited using standard MB radiofrequency pulses and the proposed SPSP-SMS pulses, yielding coverage of 36 slices in four shots with 350-ms volume pulse repetition time. The pulses were compared in breath-hold fMRI at 3T. RESULTS: The SPSP-SMS pulses recovered ∼45% of voxels with signal loss in standard SMS images. Activation in areas of signal recovery increased by 26.4% using a 12.6-ms SPSP-MB pulse and 20.3% using a 12.1-ms SPSP-PINS pulse. CONCLUSIONS: It is demonstrated that SPSP-SMS pulses can improve BOLD sensitivity in areas of signal loss across simultaneous multiple slices.
Authors: Kawin Setsompop; Borjan A Gagoski; Jonathan R Polimeni; Thomas Witzel; Van J Wedeen; Lawrence L Wald Journal: Magn Reson Med Date: 2011-08-19 Impact factor: 4.668
Authors: Mark Jenkinson; Christian F Beckmann; Timothy E J Behrens; Mark W Woolrich; Stephen M Smith Journal: Neuroimage Date: 2011-09-16 Impact factor: 6.556
Authors: David A Feinberg; Steen Moeller; Stephen M Smith; Edward Auerbach; Sudhir Ramanna; Matthias Gunther; Matt F Glasser; Karla L Miller; Kamil Ugurbil; Essa Yacoub Journal: PLoS One Date: 2010-12-20 Impact factor: 3.240