Literature DB >> 21239353

Correction of systematic set-up error in breast and head and neck irradiation through a no-action level (NAL) protocol.

Eva M Lozano1, Luis A Pérez, Javier Torres, Carmen Carrascosa, Miguel Sanz, Fermín Mendicote, Antonio Gil.   

Abstract

PURPOSE: To quantify systematic and random patient set-up errors in breast and head and neck conventional irradiation and to evaluate a no-action level (NAL) protocol for systematic set-up error off-line correction in head and neck cancer and breast cancer patients.
MATERIAL AND METHODS: Verification electronic portal images of orthogonal set-up fields were obtained daily for the initial four consecutive fractions for 20 patients treated for breast cancer and for 20 head and neck cancer patients. The calculated systematic error was used to shift the isocentre accordingly on the fifth treatment day. From then until the end of the treatment course, pair orthogonal portal images of set-up fields were obtained weekly. To assess the impact of the protocol, pre- and post-correction systematic errors were compared and PTV margins were estimated before and after correction using published margin recipes.
RESULTS: Population systematic set-up error decreased in the breast cancer patient group after the implementation of NAL protocol from 4.0 to 1.7 mm on the x-axis, from 4.7 to 2.1 mm on the y-axis and from 2.8 to 0.9 mm on the z axis. The percentage of patients with individual systematic set-up error reduction was 80%, 90% and 80% on the x-, y and z-axes respectively. Population systematic set-up error decreased also in the head and neck cancer patient group from 2.3 to 1.1 mm on the x-axis, from 1.6 to 1.4 mm on the y-axis and from 1.7 to 0.7 mm on the z-axis. The percentage of patients with individual systematic set-up error reduction was 70%, 65% and 85% on the x-, y- and z-axes respectively. Margin reduction achievable with NAL protocol implementation on the x-, y- and z-axes was 6.3, 7.2 and 4.8 mm for breast cancer patients and 3.3, 0.6 and 2.8 mm for head and neck cancer patients.
CONCLUSION: NAL off-line protocol is useful for systematic set-up error correction and PTV margin reduction in conventional breast and head and neck irradiation.

Entities:  

Mesh:

Year:  2011        PMID: 21239353     DOI: 10.1007/s12094-011-0614-0

Source DB:  PubMed          Journal:  Clin Transl Oncol        ISSN: 1699-048X            Impact factor:   3.405


  38 in total

1.  Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability.

Authors:  J C Stroom; H C de Boer; H Huizenga; A G Visser
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-03-01       Impact factor: 7.038

2.  Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report.

Authors:  Joep C Stroom; Ben J M Heijmen
Journal:  Radiother Oncol       Date:  2002-07       Impact factor: 6.280

Review 3.  Clinical use of electronic portal imaging.

Authors:  Michael G Herman
Journal:  Semin Radiat Oncol       Date:  2005-07       Impact factor: 5.934

4.  Reducing xerostomia by IMRT: what may, and may not, be achieved.

Authors:  Avraham Eisbruch
Journal:  J Clin Oncol       Date:  2007-11-01       Impact factor: 44.544

5.  eNAL: an extension of the NAL setup correction protocol for effective use of weekly follow-up measurements.

Authors:  Hans C J de Boer; Ben J M Heijmen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-04-01       Impact factor: 7.038

Review 6.  Balancing risk and reward in target delineation for highly conformal radiotherapy in head and neck cancer.

Authors:  Avraham Eisbruch; Vincent Gregoire
Journal:  Semin Radiat Oncol       Date:  2009-01       Impact factor: 5.934

7.  Generic planning target margin for rectal cancer treatment setup variation.

Authors:  John M Robertson; Jonathon P Campbell; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-01-07       Impact factor: 7.038

8.  Verification and correction of setup deviations in tangential breast irradiation using EPID: gain versus workload.

Authors:  J Pouliot; A Lirette
Journal:  Med Phys       Date:  1996-08       Impact factor: 4.071

Review 9.  Accuracy in tangential breast treatment set-up: a portal imaging study.

Authors:  G van Tienhoven; J H Lanson; D Crabeels; S Heukelom; B J Mijnheer
Journal:  Radiother Oncol       Date:  1991-12       Impact factor: 6.280

10.  Quality assurance using portal imaging: the accuracy of patient positioning in irradiation of breast cancer.

Authors:  C L Creutzberg; V G Althof; H Huizenga; A G Visser; P C Levendag
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-02-15       Impact factor: 7.038

View more
  8 in total

1.  Setup accuracy for prone and supine whole breast irradiation.

Authors:  Thomas Mulliez; Akos Gulyban; Tom Vercauteren; Annick van Greveling; Bruno Speleers; Wilfried De Neve; Liv Veldeman
Journal:  Strahlenther Onkol       Date:  2016-02-10       Impact factor: 3.621

2.  Comparison of set-up errors by breast size on wing board by portal imaging.

Authors:  Waseem Raza; Sushma Agarwal; Koilpillai Joseph Maria Das; Sellepolyam Kaliyaperumal Senthil Kumar; Punita Lal
Journal:  Rep Pract Oncol Radiother       Date:  2016-05-06

3.  A prospective analysis of inter- and intrafractional errors to calculate CTV to PTV margins in head and neck patients.

Authors:  J Cacicedo; J F Perez; R Ortiz de Zarate; O del Hoyo; F Casquero; A Gómez-Iturriaga; A Lasso; E Boveda; P Bilbao
Journal:  Clin Transl Oncol       Date:  2014-07-19       Impact factor: 3.405

4.  Automated algorithm for calculation of setup corrections and planning target volume margins for offline image-guided radiotherapy protocols.

Authors:  Auwal Abubakar; Nada Alia M Zamri; Shazril Imran Shaukat; Hafiz Mohd Zin
Journal:  J Appl Clin Med Phys       Date:  2021-06-09       Impact factor: 2.102

5.  Estimation of daily interfractional larynx residual setup error after isocentric alignment for head and neck radiotherapy: quality assurance implications for target volume and organs-at-risk margination using daily CT on- rails imaging.

Authors:  Charles A Baron; Musaddiq J Awan; Abdallah S R Mohamed; Imad Akel; David I Rosenthal; G Brandon Gunn; Adam S Garden; Brandon A Dyer; Laurence Court; Parag R Sevak; Esengul Kocak-Uzel; Clifton D Fuller
Journal:  J Appl Clin Med Phys       Date:  2014-01-08       Impact factor: 2.102

6.  Efficacy and workload analysis of a fixed vertical couch position technique and a fixed-action-level protocol in whole-breast radiotherapy.

Authors:  Saskia Petillion; Karolien Verhoeven; Caroline Weltens; Frank Van den Heuvel
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

7.  Accuracy of a new paired imaging technique for position correction in whole breast radiotherapy.

Authors:  Saskia Petillion; Karolien Verhoeven; Caroline Weltens; Frank Van den Heuvel
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

8.  Adaptive sequential plan-on-plan optimization during prostate-specific antigen response guided radiotherapy of recurrent prostate cancer.

Authors:  Vilberg Jóhannesson; Elinore Wieslander; Per Nilsson; Eva Brun; Ulrika Bitzén; Göran Ahlgren; Tomas Olsson; Sven Bäck; Elisabeth Kjellén; Adalsteinn Gunnlaugsson
Journal:  Phys Imaging Radiat Oncol       Date:  2021-03-26
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.