Literature DB >> 21227619

Test-retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects.

Marica Cutajar1, Jonathan D Clayden, Christopher A Clark, Isky Gordon.   

Abstract

PURPOSE: This study assessed test-retest reliability and repeatability of diffusion tensor imaging (DTI) in the kidneys.
MATERIALS AND METHODS: Seven healthy volunteers (age range, 19-31 years), were imaged three consecutive times on the same day (short-term reliability) and the same imaging protocol was repeated after a month (long-term reliability). Diffusion-weighted magnetic resonance imaging scans in the coronal-oblique projection of the kidney were acquired on a 1.5 T scanner using a multi-section echo-planar sequence; six contiguous slices each 5 mm thick, diffusion sensitisation along 20 non-collinear directions, TR=730 ms, TE=73 ms and 2 b-values (0 and 400 s mm(-2)). Volunteers were asked to hold their breath throughout each data acquisition (approx. 20 s). The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were obtained from maps generated using dedicated software MIStar (Apollo Medical Imaging, Melbourne, Australia).
RESULTS: Statistical analyses of both short- and long-term repeats were carried out from which the within-subject coefficient of variation (wsCV) was calculated. The wsCV obtained for both the ADC and FA values were less than 10% in all the analyses carried out. In addition, paired (repeated measures) t-test was used to measure the variation between the diffusion parameters collected from the two scanning sessions a month apart. It showed no significant difference and the wsCV obtained after comparing the first and second scans were found to be smaller than 15% for both ADC and FA.
CONCLUSION: Renal DTI produces reliable and repeatable results which make longitudinal investigation of patients viable.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21227619     DOI: 10.1016/j.ejrad.2010.12.018

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  17 in total

1.  Lateralization of temporal lobe epilepsy using a novel uncertainty analysis of MR diffusion in hippocampus, cingulum, and fornix, and hippocampal volume and FLAIR intensity.

Authors:  Mohammad-Reza Nazem-Zadeh; Jason M Schwalb; Kost V Elisevich; Hassan Bagher-Ebadian; Hajar Hamidian; Ali-Reza Akhondi-Asl; Kourosh Jafari-Khouzani; Hamid Soltanian-Zadeh
Journal:  J Neurol Sci       Date:  2014-05-16       Impact factor: 3.181

2.  Assessment of renal allograft function early after transplantation with isotropic resolution diffusion tensor imaging.

Authors:  Wen-jun Fan; Tao Ren; Qiong Li; Pan-li Zuo; Miao-miao Long; Chun-bai Mo; Li-hua Chen; Li-xiang Huang; Wen Shen
Journal:  Eur Radiol       Date:  2015-05-28       Impact factor: 5.315

3.  Test-retest reliability of diffusion tensor imaging of the liver at 3.0 T.

Authors:  Rossano Girometti; Marta Maieron; Giovanni Lissandrello; Massimo Bazzocchi; Chiara Zuiani
Journal:  Radiol Med       Date:  2014-11-25       Impact factor: 3.469

4.  MR elastography in renal transplant patients and correlation with renal allograft biopsy: a feasibility study.

Authors:  Christine U Lee; James F Glockner; Kevin J Glaser; Meng Yin; Jun Chen; Akira Kawashima; Bohyun Kim; Walter K Kremers; Richard L Ehman; James M Gloor
Journal:  Acad Radiol       Date:  2012-04-13       Impact factor: 3.173

5.  Diffusion tensor imaging MRI of sickle cell kidney disease: initial results and comparison with iron deposition.

Authors:  Shannon B Donnola; Connie M Piccone; Lan Lu; Joshua Batesole; Jane Little; Katherine M Dell; Chris A Flask
Journal:  NMR Biomed       Date:  2018-01-19       Impact factor: 4.044

6.  DTI for the assessment of disease stage in patients with glomerulonephritis--correlation with renal histology.

Authors:  Qiang Feng; Zhijun Ma; Jianlin Wu; Wei Fang
Journal:  Eur Radiol       Date:  2014-07-21       Impact factor: 5.315

7.  Uncertainty in assessment of radiation-induced diffusion index changes in individual patients.

Authors:  Mohammad-Reza Nazem-Zadeh; Christopher H Chapman; Theodore S Lawrence; Christina I Tsien; Yue Cao
Journal:  Phys Med Biol       Date:  2013-06-04       Impact factor: 3.609

8.  Diffusion tensor imaging and tractography of the kidneys: assessment of chronic parenchymal diseases.

Authors:  Caterina Gaudiano; Valeria Clementi; Fiorenza Busato; Beniamino Corcioni; Maria Grazia Orrei; Emiliana Ferramosca; Emma Fabbri; Paola Berardi; Antonio Santoro; Rita Golfieri
Journal:  Eur Radiol       Date:  2013-01-09       Impact factor: 5.315

9.  MR scanner systems should be adequately characterized in diffusion-MRI of the breast.

Authors:  Marco Giannelli; Roberto Sghedoni; Chiara Iacconi; Mauro Iori; Antonio Claudio Traino; Maria Guerrisi; Mario Mascalchi; Nicola Toschi; Stefano Diciotti
Journal:  PLoS One       Date:  2014-01-28       Impact factor: 3.240

10.  High-resolution diffusion tensor imaging of the human kidneys using a free-breathing, multi-slice, targeted field of view approach.

Authors:  Rachel W Chan; Constantin Von Deuster; Christian T Stoeck; Jack Harmer; Shonit Punwani; Navin Ramachandran; Sebastian Kozerke; David Atkinson
Journal:  NMR Biomed       Date:  2014-09-15       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.