Preliminary commissioning investigations with the DMOS-RPC optical-CT Scanner.

J Newton1, A Thomas, G Ibbott, M Oldham.   

Abstract

A midsized broad beam Optical-CT scanner is being developed for collaborative research between Duke and the Radiological Physics Center (RPC). The Duke Midsized Optical-CT Scanner (DMOS-RPC) is designed to be compatible with several of the RPC phantoms, including the head and neck, stereotactic SRS, and lung phantoms. Preliminary data investigating the basic performance of the scanner is described. Two 10 cm PRESAGE cylinders were irradiated with simple test plans. Projections of ~80 μm resolution of each dosimeter were collected at 1 degree intervals over a full 360 degrees both before and after irradiation. 3 dimensional reconstructions of attenuation coefficients throughout the dosimeter were computed with 1 mm(3) resolution. Scans were normalized to the calculated dose distribution and a 3D comparison was made with a commissioned treatment planning system. Initial results indicate DMOS-RPC can produce accurate relative dose distributions with high spatial resolution (up to 1 mm(3) in 3D) in less than 30 minutes (acquisition and reconstruction). A maximum dose of ~3.6Gy was delivered in these tests, and observed noise was ~2% for 1 mm(3) reconstructions. Good agreement is observed with the planning system in these simple distributions, indicating promising potential for this scanner.

Entities:  

Year:  2010        PMID: 21218171      PMCID: PMC3015184          DOI: 10.1088/1742-6596/250/1/012078

Source DB:  PubMed          Journal:  J Phys Conf Ser        ISSN: 1742-6588


  7 in total

1.  Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry.

Authors:  Nikola Krstajić; Simon J Doran
Journal:  Phys Med Biol       Date:  2006-04-03       Impact factor: 3.609

2.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.

Authors:  H S Sakhalkar; M Oldham
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

3.  A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system.

Authors:  H S Sakhalkar; J Adamovics; G Ibbott; M Oldham
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

4.  Investigation of the feasibility of relative 3D dosimetry in the Radiologic Physics Center Head and Neck IMRT phantom using presage/optical-CT.

Authors:  Harshad Sakhalkar; David Sterling; John Adamovics; Geoffrey Ibbott; Mark Oldham
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

5.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner.

Authors:  J C Gore; M Ranade; M J Maryañski; R J Schulz
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

6.  CCD imaging for optical tomography of gel radiation dosimeters.

Authors:  J G Wolodzko; C Marsden; A Appleby
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

7.  Fast, large field-of-view, telecentric optical-CT scanning system for 3D radiochromic dosimetry.

Authors:  A Thomas; M Oldham
Journal:  J Phys Conf Ser       Date:  2010-01-01
  7 in total
  7 in total

1.  PRESAGE 3D dosimetry accurately measures Gamma Knife output factors.

Authors:  Slade J Klawikowski; James N Yang; John Adamovics; Geoffrey S Ibbott
Journal:  Phys Med Biol       Date:  2014-11-04       Impact factor: 3.609

2.  On the feasibility of polyurethane based 3D dosimeters with optical CT for dosimetric verification of low energy photon brachytherapy seeds.

Authors:  Justus Adamson; Yun Yang; Titania Juang; Kelsey Chisholm; Leith Rankine; John Adamovics; Fang Fang Yin; Mark Oldham
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

3.  An investigation of PRESAGE® 3D dosimetry for IMRT and VMAT radiation therapy treatment verification.

Authors:  Jake Jackson; Titania Juang; John Adamovics; Mark Oldham
Journal:  Phys Med Biol       Date:  2015-02-16       Impact factor: 3.609

4.  Feasibility of using PRESAGE® for relative 3D dosimetry of small proton fields.

Authors:  Li Zhao; Joseph Newton; Mark Oldham; Indra J Das; Chee-Wai Cheng; John Adamovics
Journal:  Phys Med Biol       Date:  2012-10-26       Impact factor: 3.609

5.  Investigating end-to-end accuracy of image guided radiation treatment delivery using a micro-irradiator.

Authors:  L J Rankine; J Newton; S T Bache; S K Das; J Adamovics; D G Kirsch; M Oldham
Journal:  Phys Med Biol       Date:  2013-10-18       Impact factor: 3.609

6.  Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid.

Authors:  Steven Bache; Javian Malcolm; John Adamovics; Mark Oldham
Journal:  PLoS One       Date:  2016-03-28       Impact factor: 3.240

7.  Comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film with a commercial radiation treatment planning system for breast IMRT: a feasibility study.

Authors:  Khalid Iqbal; Kent A Gifford; Geoffrey Ibbott; Ryan L Grant; Saeed Buzdar
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.