In Vitro Simulation and Validation of the Circulation with Congenital Heart Defects.

Richard S Figliola1, Alessandro Giardini, Tim Conover, Tiffany A Camp, Giovanni Biglino, John Chiulli, Tain-Yen Hsia.   

Abstract

Despite the recent advances in computational modeling, experimental simulation of the circulation with congenital heart defect using mock flow circuits remains an important tool for device testing, and for detailing the probable flow consequences resulting from surgical and interventional corrections. Validated mock circuits can be applied to qualify the results from novel computational models. New mathematical tools, coupled with advanced clinical imaging methods, allow for improved assessment of experimental circuit performance relative to human function, as well as the potential for patient-specific adaptation. In this review, we address the development of three in vitro mock circuits specific for studies of congenital heart defects. Performance of an in vitro right heart circulation circuit through a series of verification and validation exercises is described, including correlations with animal studies, and quantifying the effects of circuit inertiance on test results. We present our experience in the design of mock circuits suitable for investigations of the characteristics of the Fontan circulation. We use one such mock circuit to evaluate the accuracy of Doppler predictions in the presence of aortic coarctation.

Entities:  

Year:  2010        PMID: 21218147      PMCID: PMC3014583          DOI: 10.1016/j.ppedcard.2010.09.009

Source DB:  PubMed          Journal:  Prog Pediatr Cardiol        ISSN: 1058-9813


  23 in total

1.  Single-step stereolithography of complex anatomical models for optical flow measurements.

Authors:  Diane de Zélicourt; Kerem Pekkan; Hiroumi Kitajima; David Frakes; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2005-02       Impact factor: 2.097

2.  Global mathematical modelling of the Norwood circulation: a multiscale approach for the study of the pulmonary and coronary arterial perfusions.

Authors:  Francesco Migliavacca; Katia Laganà; Giancarlo Pennati; Marc R de Leval; Edward L Bove; Gabriele Dubini
Journal:  Cardiol Young       Date:  2004       Impact factor: 1.093

3.  Comparative in vitro study of bileaflet and tilting disk valve behavior in the pulmonary position.

Authors:  Jeffrey Gohean; Richard Figliola; Tiffany Camp; Tim McQuinn
Journal:  J Biomech Eng       Date:  2006-08       Impact factor: 2.097

4.  In vitro study of flow regulation for pulmonary insufficiency.

Authors:  T A Camp; K C Stewart; R S Figliola; T McQuinn
Journal:  J Biomech Eng       Date:  2007-04       Impact factor: 2.097

5.  Percutaneous pulmonary valve implantation based on rapid prototyping of right ventricular outflow tract and pulmonary trunk from MR data.

Authors:  Silvia Schievano; Francesco Migliavacca; Louise Coats; Sachin Khambadkone; Mario Carminati; Neil Wilson; John E Deanfield; Philipp Bonhoeffer; Andrew M Taylor
Journal:  Radiology       Date:  2007-02       Impact factor: 11.105

6.  Turbulent/viscous interactions control Doppler/catheter pressure discrepancies in aortic stenosis. The role of the Reynolds number.

Authors:  E G Cape; M Jones; I Yamada; M D VanAuker; L M Valdes-Cruz
Journal:  Circulation       Date:  1996-12-01       Impact factor: 29.690

7.  Extraction of pulmonary vascular compliance, pulmonary vascular resistance, and right ventricular work from single-pressure and Doppler flow measurements in children with pulmonary hypertension: a new method for evaluating reactivity: in vitro and clinical studies.

Authors:  Craig E Weinberg; Jean R Hertzberg; D Dunbar Ivy; K Scott Kirby; K Chen Chan; Lilliam Valdes-Cruz; Robin Shandas
Journal:  Circulation       Date:  2004-10-18       Impact factor: 29.690

8.  Doppler evaluation of aortic valve area in children with aortic stenosis.

Authors:  A R Bengur; A R Snider; J N Meliones; R P Vermilion
Journal:  J Am Coll Cardiol       Date:  1991-11-15       Impact factor: 24.094

9.  Total cavopulmonary connection: a logical alternative to atriopulmonary connection for complex Fontan operations. Experimental studies and early clinical experience.

Authors:  M R de Leval; P Kilner; M Gewillig; C Bull
Journal:  J Thorac Cardiovasc Surg       Date:  1988-11       Impact factor: 5.209

10.  Multiscale modelling in biofluidynamics: application to reconstructive paediatric cardiac surgery.

Authors:  Francesco Migliavacca; Rossella Balossino; Giancarlo Pennati; Gabriele Dubini; Tain-Yen Hsia; Marc R de Leval; Edward L Bove
Journal:  J Biomech       Date:  2005-04-25       Impact factor: 2.712

View more
  6 in total

1.  Experimental Investigation of the Effect of Non-Newtonian Behavior of Blood Flow in the Fontan Circulation.

Authors:  Andrew L Cheng; Niema M Pahlevan; Derek G Rinderknecht; John C Wood; Morteza Gharib
Journal:  Eur J Mech B Fluids       Date:  2017-12-27       Impact factor: 2.183

2.  Hemodynamic study of TCPC using in vivo and in vitro 4D Flow MRI and numerical simulation.

Authors:  Alejandro Roldán-Alzate; Sylvana García-Rodríguez; Petros V Anagnostopoulos; Shardha Srinivasan; Oliver Wieben; Christopher J François
Journal:  J Biomech       Date:  2015-03-19       Impact factor: 2.712

3.  A novel 3D-Printed preferential posterior mitral annular dilation device delineates regurgitation onset threshold in an ex vivo heart simulator.

Authors:  Annabel M Imbrie-Moore; Cole C Paullin; Michael J Paulsen; Frederick Grady; Hanjay Wang; Camille E Hironaka; Justin M Farry; Haley J Lucian; Y Joseph Woo
Journal:  Med Eng Phys       Date:  2020-01-31       Impact factor: 2.242

4.  Simulating Radial Pressure Waveforms with a Mock Circulatory Flow Loop to Characterize Hemodynamic Monitoring Systems.

Authors:  Anna Packy; Gavin A D'Souza; Masoud Farahmand; Luke Herbertson; Christopher G Scully
Journal:  Cardiovasc Eng Technol       Date:  2021-09-01       Impact factor: 2.305

5.  A Mock Circulatory System Incorporating a Compliant 3D-Printed Anatomical Model to Investigate Pulmonary Hemodynamics.

Authors:  Paul G M Knoops; Giovanni Biglino; Alun D Hughes; Kim H Parker; Linzhang Xu; Silvia Schievano; Ryo Torii
Journal:  Artif Organs       Date:  2016-12-07       Impact factor: 3.094

6.  Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing.

Authors:  Giovanni Biglino; Peter Verschueren; Raf Zegels; Andrew M Taylor; Silvia Schievano
Journal:  J Cardiovasc Magn Reson       Date:  2013-01-16       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.