Literature DB >> 16813455

Comparative in vitro study of bileaflet and tilting disk valve behavior in the pulmonary position.

Jeffrey Gohean1, Richard Figliola, Tiffany Camp, Tim McQuinn.   

Abstract

A study of mechanical heart valve behavior in the pulmonary position as a function of pulmonary vascular resistance is reported for the St. Jude Medical bileaflet (SJMB) valve and the MedicalCV Omnicarbon (OTD) tilting disk valve. Tests were conducted in a pulmonic mock circulatory system and impedance was varied in terms of system pulmonary vascular resistance (PVR). An impedance spectrum was found using instantaneous pulmonary artery pressure and flow rate curves. Both valves fully opened and closed at and above a nominal PVR of 3.0 mmHg/L/min. The SJMB valve was prone to leaflet bounce at closure, but otherwise completely closed, at settings above and below this nominal setting. At PVR values at and below 2.0 mmHg/L/min, the SJMB valve exhibited two types of leaflet aberrant behavior: single leaflet only closure while the other leaflet fluttered, and incomplete closure where both leaflets flutter but neither remain fully closed. The OTD valve fully opened and closed to a PVR value of 1.6 mmHg/L/min. At lower values, the valve did not close. Valves designed for the left heart can show aberrant behavior under normal conditions as pulmonary valves.

Entities:  

Mesh:

Year:  2006        PMID: 16813455     DOI: 10.1115/1.2206204

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  4 in total

1.  In vitro study of flow regulation for pulmonary insufficiency.

Authors:  T A Camp; K C Stewart; R S Figliola; T McQuinn
Journal:  J Biomech Eng       Date:  2007-04       Impact factor: 2.097

2.  Imaging and patient-specific simulations for the Fontan surgery: current methodologies and clinical applications.

Authors:  Diane A de Zélicourt; Alison Marsden; Mark A Fogel; Ajit P Yoganathan
Journal:  Prog Pediatr Cardiol       Date:  2010-12-01

3.  In Vitro Simulation and Validation of the Circulation with Congenital Heart Defects.

Authors:  Richard S Figliola; Alessandro Giardini; Tim Conover; Tiffany A Camp; Giovanni Biglino; John Chiulli; Tain-Yen Hsia
Journal:  Prog Pediatr Cardiol       Date:  2010-12-01

4.  A Mock Circulatory System Incorporating a Compliant 3D-Printed Anatomical Model to Investigate Pulmonary Hemodynamics.

Authors:  Paul G M Knoops; Giovanni Biglino; Alun D Hughes; Kim H Parker; Linzhang Xu; Silvia Schievano; Ryo Torii
Journal:  Artif Organs       Date:  2016-12-07       Impact factor: 3.094

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.