In vitro study of flow regulation for pulmonary insufficiency.

T A Camp1, K C Stewart, R S Figliola, T McQuinn.   

Abstract

Given the tolerance of the right heart circulation to mild regurgitation and gradient, we study the potential of using motionless devices to regulate the pulmonary circulation. In addition, we document the flow performance of two mechanical valves. A motionless diode, a nozzle, a mechanical bileaflet valve, and a tilting disk valve were tested in a pulmonary mock circulatory system over the normal human range of pulmonary vascular resistance (PVR). For the mechanical valves, regurgitant fractions (RFs) and transvalvular pressure gradients were found to be weak functions of PVR. On the low end of normal PVR, the bileaflet and tilting disk valves fluttered and would not fully close. Despite this anomaly, the regurgitant fraction of either valve did not change significantly. The values for RF and transvalvular gradient measured varied from 4 to 7% and 4 to 7 mm Hg, respectively, at 5 lpm for all tests. The diode valve was able to regulate flow with mild regurgitant fraction and trivial gradient but with values higher than either mechanical valve tested. Regurgitant fraction ranged from 2 to 17% in tests extending from PVR values of 1 to 4.5 mm Hg/lpm at 5 lpm and with concomitant increases in gradient up to 17 mm Hg. The regurgitant fraction for the nozzle increased from 2 to 23% over the range of PVR with gradients increasing to 18 mm Hg. The significant findings were: (1) the mechanical valves controlled regurgitation at normal physiological cardiac output and PVR even though they failed to close at some normal values of PVR and showed leaflet flutter; and (2) it may be possible to regulate the pulmonary circulation to tolerable levels using a motionless pulmonary valve device.

Entities:  

Mesh:

Year:  2007        PMID: 17408334      PMCID: PMC2140231          DOI: 10.1115/1.2540892

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  14 in total

1.  Factors associated with impaired clinical status in long-term survivors of tetralogy of Fallot repair evaluated by magnetic resonance imaging.

Authors:  Tal Geva; Bryan M Sandweiss; Kimberlee Gauvreau; James E Lock; Andrew J Powell
Journal:  J Am Coll Cardiol       Date:  2004-03-17       Impact factor: 24.094

2.  In vitro closing behavior of the St. Jude Medical heart valve in the pulmonary position. Valve incompetence originating in the prosthesis itself.

Authors:  Y Kiyota; T Shiroyama; T Akamatsu; Y Yokota; T Ban
Journal:  J Thorac Cardiovasc Surg       Date:  1992-09       Impact factor: 5.209

3.  Comparative in vitro study of bileaflet and tilting disk valve behavior in the pulmonary position.

Authors:  Jeffrey Gohean; Richard Figliola; Tiffany Camp; Tim McQuinn
Journal:  J Biomech Eng       Date:  2006-08       Impact factor: 2.097

4.  Mechanical valves in the pulmonary position: a reappraisal.

Authors:  L Rosti; B Murzi; A M Colli; P Festa; S Redaelli; L Havelova; L Menicanti; A Frigiola
Journal:  J Thorac Cardiovasc Surg       Date:  1998-05       Impact factor: 5.209

5.  Pulsatile flow past St. Jude Medical bileaflet valve. An in vitro study.

Authors:  K B Chandran
Journal:  J Thorac Cardiovasc Surg       Date:  1985-05       Impact factor: 5.209

6.  In-vitro pulsatile flow visualization studies in a pulmonary artery model.

Authors:  E Philpot; A P Yoganathan; H W Sung; Y R Woo; R H Franch; D J Sahn; L Valdez-Cruz
Journal:  J Biomech Eng       Date:  1985-11       Impact factor: 2.097

7.  Experience with St. Jude Medical valve prosthesis in children. A word of caution regarding right-sided placement.

Authors:  M N Ilbawi; C G Lockhart; F S Idriss; S Y DeLeon; A J Muster; C E Duffy; M H Paul
Journal:  J Thorac Cardiovasc Surg       Date:  1987-01       Impact factor: 5.209

8.  Right ventricular dysfunction and pulmonary valve replacement after correction of tetralogy of Fallot.

Authors:  Frank T H de Ruijter; Ineke Weenink; Francois J Hitchcock; Erik J Meijboom; Ger B W E Bennink
Journal:  Ann Thorac Surg       Date:  2002-06       Impact factor: 4.330

9.  Valve replacement in children: guidelines for selection of prosthesis and timing of surgical intervention.

Authors:  M N Ilbawi; F S Idriss; S Y DeLeon; A J Muster; C E Duffy; S S Gidding; M H Paul
Journal:  Ann Thorac Surg       Date:  1987-10       Impact factor: 4.330

10.  Comparative study between St. Jude Medical and bioprosthetic valves in the right side of the heart.

Authors:  Y Kawachi; M Masuda; R Tominaga; K Tokunaga
Journal:  Jpn Circ J       Date:  1991-06
View more
  2 in total

1.  Imaging and patient-specific simulations for the Fontan surgery: current methodologies and clinical applications.

Authors:  Diane A de Zélicourt; Alison Marsden; Mark A Fogel; Ajit P Yoganathan
Journal:  Prog Pediatr Cardiol       Date:  2010-12-01

2.  In Vitro Simulation and Validation of the Circulation with Congenital Heart Defects.

Authors:  Richard S Figliola; Alessandro Giardini; Tim Conover; Tiffany A Camp; Giovanni Biglino; John Chiulli; Tain-Yen Hsia
Journal:  Prog Pediatr Cardiol       Date:  2010-12-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.