Literature DB >> 21210093

Use of 320-detector computed tomographic angiography for infants and young children with congenital heart disease.

Faris Al-Mousily1, Roger Y Shifrin, Frederick J Fricker, Nicholas Feranec, Nancy S Quinn, Arun Chandran.   

Abstract

Pediatric patients with complex congenital heart disease (CHD) face a lifetime of treatment with interventional therapeutic and palliative procedures. Echocardiography remains the mainstay for noninvasive imaging of congenital heart lesions. This often is supplemented with diagnostic cardiac catheterization for additional anatomic and physiologic characterization. However, recent technological improvements in computed tomography (CT) and magnetic resonance imaging (MRI) have led to an increased focus on the use of these techniques given their better safety profile. This study aimed to review the authors' experience with a 320-slice multidetector CT scanner in the evaluation of CHD in children. This retrospective case study investigated 22 infants and young children with a provisional diagnosis of CHD. Their anatomic evaluation was performed using a 320-slice Aquilon ONE CT scanner. Of these 22 patients, 14 were examined without cardiac gating. This was subsequently modified to a prospective gated, targeted protocol to decrease the radiation dose. The images were interpreted by an experienced radiologist and a pediatric cardiologist. Continuous variables were expressed as mean and standard deviation or range, and the two imaging protocols were compared. A comparison of exposure rates with those from other pediatric studies that had used the 64-slice CT angiography also was performed. For the first group of patients, with nongated CT examinations, the mean effective whole-body radiation dose was 1.8 ± 0.71 millisieverts (mSv) (range, 0.96-3.2 mSv). For the second group, the mean was 0.8 ± 0.39 mSv (range, 0.4-1.5 mSv). Although the radiation dose was reduced dramatically, clinicians must be vigilant about the cumulative risk of radiation exposure.

Entities:  

Mesh:

Year:  2011        PMID: 21210093     DOI: 10.1007/s00246-010-9873-8

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  16 in total

1.  Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Ravi S Kamath; Elkan F Halpern; Sanjay Saini
Journal:  Radiology       Date:  2004-08       Impact factor: 11.105

2.  CT angiography in children: it is accurate, but is it safe?

Authors:  Lawrence M Boxt
Journal:  JACC Cardiovasc Imaging       Date:  2008-05

3.  Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation.

Authors:  Christopher Herzog; Denise M Mulvihill; Shaun A Nguyen; Giancarlo Savino; Bernhard Schmidt; Philip Costello; Thomas J Vogl; U Joseph Schoepf
Journal:  AJR Am J Roentgenol       Date:  2008-05       Impact factor: 3.959

4.  Patient radiation doses from adult and pediatric CT.

Authors:  Walter Huda; Awais Vance
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

5.  Detection of urinary tract stones at low-radiation-dose CT with z-axis automatic tube current modulation: phantom and clinical studies.

Authors:  Mannudeep K Kalra; Michael M Maher; Roy V D'Souza; Stefania Rizzo; Elkan F Halpern; Michael A Blake; Sanjay Saini
Journal:  Radiology       Date:  2005-03-15       Impact factor: 11.105

6.  An institutional review of the value of computed tomographic angiography in the diagnosis of congenital cardiac malformations.

Authors:  Arun Chandran; F Jay Fricker; Kenneth O Schowengerdt; William A Cumming; Arwa Saidi; Carolyn T Spencer; Joseph Paolillo; Margaret M Samyn
Journal:  Cardiol Young       Date:  2005-02       Impact factor: 1.093

7.  Strategies for dose-optimized imaging in pediatric cardiac dual source CT.

Authors:  A Kuettner; B Gehann; J Spolnik; A Koch; S Achenbach; M Weyand; S Dittrich; M Uder; G Staatz
Journal:  Rofo       Date:  2009-03-16

8.  Low-dose coronary artery computed tomography angiogram of an infant with tetralogy of fallot using a 256-slice multidetector computed tomography scanner.

Authors:  Dianna M E Bardo; Jane Asamato; Charles S Mackay; Mary Minette
Journal:  Pediatr Cardiol       Date:  2009-02-12       Impact factor: 1.655

9.  Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease.

Authors:  Lamia Ait-Ali; Maria Grazia Andreassi; Ilenia Foffa; Isabella Spadoni; Eliseo Vano; Eugenio Picano
Journal:  Heart       Date:  2009-08-16       Impact factor: 5.994

Review 10.  Conventional and CT angiography in children: dosimetry and dose comparisons.

Authors:  Donald P Frush; Terry Yoshizumi
Journal:  Pediatr Radiol       Date:  2006-09
View more
  20 in total

1.  Detection of pulmonary arterial morphology in tetralogy of Fallot with pulmonary atresia by computed tomography: 12 years of experience.

Authors:  Ming-Tai Lin; Jou-Kou Wang; Yih-Sharng Chen; Wen-Jeng Lee; Hsin-Hui Chiu; Chun-An Chen; Shuenn-Nan Chiu; En-Ting Wu; Chun-Wei Lu; Shu-Chien Huang; Shyh-Jye Chen; Ing-Sh Chiu; Chung-I Chang; Mei-Hwan Wu
Journal:  Eur J Pediatr       Date:  2011-11-15       Impact factor: 3.183

2.  Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.

Authors:  Oliver Rompel; Martin Glöckler; Rolf Janka; Sven Dittrich; Robert Cesnjevar; Michael M Lell; Michael Uder; Matthias Hammon
Journal:  Pediatr Radiol       Date:  2016-01-06

3.  Assessments of Coronary Artery Visibility and Radiation Dose in Infants with Congenital Heart Disease on Cardiac 128-slice CT and on Cardiac 64-slice CT.

Authors:  Y Cui; M Huang; J Zheng; J Li; H Liu; C Liang
Journal:  Pediatr Cardiol       Date:  2015-08-14       Impact factor: 1.655

4.  Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease.

Authors:  Pei Nie; Ximing Wang; Zhaoping Cheng; Xiaopeng Ji; Yanhua Duan; Jiuhong Chen
Journal:  Eur Radiol       Date:  2012-05-18       Impact factor: 5.315

5.  Radiation dose reduction in pediatric cardiac computed tomography: experience from a tertiary medical center.

Authors:  Brian B Ghoshhajra; Ashley M Lee; Leif-Christopher Engel; Csilla Celeng; Mannudeep K Kalra; Thomas J Brady; Udo Hoffmann; Sjirk J Westra; Suhny Abbara
Journal:  Pediatr Cardiol       Date:  2013-07-20       Impact factor: 1.655

6.  Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT.

Authors:  Jennifer H Johnston; Daniel J Podberesky; Terry T Yoshizumi; Erin Angel; Greta Toncheva; David B Larson; John C Egelhoff; Colin Anderson-Evans; Giao B Nguyen; Alessandra Barelli; Christopher Alsip; Shelia R Salisbury; Donald P Frush
Journal:  Pediatr Radiol       Date:  2013-05-01

7.  Initial experience on the application of 320-row CT angiography with low-dose prospective ECG-triggered in children with congenital heart disease.

Authors:  Tong Zhang; Wei Wang; Zhuren Luo; Dan Wang; Jinquan Bai; Dong Han; Baozhong Shen
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-28       Impact factor: 2.357

8.  Comparison of image quality between synthetic and patients' electrocardiogram-gated 320-row pediatric cardiac computed tomography.

Authors:  Eriko Maeda; Go Shirota; Eisuke Shibata; Shuhei Komatsu; Kenji Ino; Rumiko Torigoe; Osamu Abe
Journal:  Pediatr Radiol       Date:  2019-12-19

9.  Application of low-dose dual-source computed tomography angiography in children with complex congenital heart disease.

Authors:  Xian-Feng Chen; Fan Jiang; Lin Li; Yan Chen; Xin Chen; Yan-Yan Jiang; Li Xiang; Xiao-Jing Ma
Journal:  Exp Ther Med       Date:  2017-06-13       Impact factor: 2.447

10.  Assessment of coronary artery by prospective ECG-triggered 256 multi-slice CT on children with congenital heart disease.

Authors:  Li-Ping Yao; Li Zhang; Hui-Ming Li; Ming Ding; Ling-Wei Yu; Xin Yang; Xiao-Ming Li; Kun Sun
Journal:  Int J Cardiovasc Imaging       Date:  2017-05-18       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.