Literature DB >> 21188958

Intrasubject repeatability of internal aberrometry obtained with a new integrated aberrometer.

David P Piñero1, Javier Tomás Juan, Jorge L Alió.   

Abstract

PURPOSE: To evaluate the intrasubject repeatability of the internal aberrometry obtained with a new integrated aberrometer in a sample of normal eyes to assess its clinical usefulness.
METHODS: Twenty-six healthy eyes of 26 participants, aged 20 to 50 years, were included in the study. All eyes achieved corrected distance visual acuity of 1.0 (Snellen decimal notation) and did not undergo previous ocular surgeries. Three consecutive measurements of internal aberrations were obtained with the KR-1W system (Topcon Corp) by an experienced examiner. Intrasubject repeatability for 4- and 6-mm pupils was evaluated by the within-subject standard deviation (S(w)) and intraclass correlation coefficient (ICC).
RESULTS: Low values of S(w) and values of ICC close to 1 were found for the 4-mm pupil astigmatism and for several aberrometric coefficients: primary spherical aberration and higher order, third order, and trefoil root-mean-square (RMS). Significant correlations of the S(w) for the 4-mm pupil higher order aberrations RMS with the magnitude of different aberrometric coefficients were found (r≥0.611, P<.01). In addition, tetrafoil RMS for 4-mm pupils correlated significantly with the S(w) for some higher order errors (r≥0.675, P<.01). Significantly larger values of S(w) for 6-mm pupils were found for trefoil (P<.01) and secondary astigmatism RMS (P=.02).
CONCLUSIONS: The KR-1W provided repeatable measurements of internal astigmatism and some higher order aberrations, although consistency of such measurements appears to be limited by the level of aberration. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Year:  2010        PMID: 21188958     DOI: 10.3928/1081597X-20101214-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  11 in total

1.  Comparison of two types of visual quality analyzer for the measurement of high order aberrations.

Authors:  Jing Hao; Lin Li; Fang Tian; Hong Zhang
Journal:  Int J Ophthalmol       Date:  2016-02-18       Impact factor: 1.779

2.  The relationship between higher-order aberrations and amblyopia treatment in hyperopic anisometropic amblyopia.

Authors:  Soo Han Lee; Ji Woong Chang
Journal:  Korean J Ophthalmol       Date:  2014-01-21

3.  Precision (Repeatability and Reproducibility) and Agreement of Corneal Power Measurements Obtained by Topcon KR-1W and iTrace.

Authors:  Yanjun Hua; Zequan Xu; Wei Qiu; Qiang Wu
Journal:  PLoS One       Date:  2016-01-11       Impact factor: 3.240

4.  Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes.

Authors:  David P Piñero; Inmaculada Cabezos; Alberto López-Navarro; Dolores de Fez; María T Caballero; Vicente J Camps
Journal:  BMC Ophthalmol       Date:  2017-10-18       Impact factor: 2.209

5.  Changes in meibomian gland morphology and ocular higher-order aberrations in eyes with chalazion.

Authors:  Shima Fukuoka; Reiko Arita; Rika Shirakawa; Naoyuki Morishige
Journal:  Clin Ophthalmol       Date:  2017-05-30

6.  Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability.

Authors:  David P Piñero; Alberto López-Navarro; Inmaculada Cabezos; Dolores de Fez; María T Caballero; Vicent J Camps
Journal:  J Ophthalmol       Date:  2017-01-04       Impact factor: 1.909

7.  Intrasession repeatability of refractive and ocular aberrometric measurements obtained using a multidiagnostic device in healthy eyes.

Authors:  David P Piñero; Alberto López-Navarro; Inmaculada Cabezos; Dolores de Fez; María T Caballero; Vicent J Camps
Journal:  Clin Optom (Auckl)       Date:  2017-05-04

8.  Clinical outcomes with a new microincisional diffractive multifocal IOL.

Authors:  Jorge L Alió; Alfredo Vega-Estrada; Ana B Plaza-Puche
Journal:  Eye Vis (Lond)       Date:  2015-01-31

9.  Precision and agreement of higher order aberrations measured with ray tracing and Hartmann-Shack aberrometers.

Authors:  Zequan Xu; Yanjun Hua; Wei Qiu; Guoqiang Li; Qiang Wu
Journal:  BMC Ophthalmol       Date:  2018-01-27       Impact factor: 2.209

10.  Ocular residual and corneal astigmatism in a clinical population of high school students.

Authors:  Zhao Chen; Luoru Liu; Chenglin Pan; Xiaoning Li; Lun Pan; Weizhong Lan; Zhikuan Yang
Journal:  PLoS One       Date:  2018-04-09       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.