Number of biopsies in diagnosing pulmonary nodules.

M Wehrschuetz1, E Wehrschuetz, H R Portugaller.   

Abstract

PURPOSE: To determine the number of specimens to be obtained from pulmonary lesions to get the highest possible accuracy in histological work-up.
MATERIALS AND METHODS: A retrospective evaluation (January 1999 to April 2004) covered 260 patients with thoracic lesions who underwent computer tomography (CT)-guided core-cut biopsy in coaxial technique. All biopsies were performed utilizing a 19 gauge introducer needle and a 20 gauge core-cut biopsy needle. In all, 669 usable biopsies were taken (from 1-5 biopsies in each setting). The specimens were marked sequentially and each biopsy was worked up histologicaly. The biopsy results were correlated to histology after surgery, clinical follow-up or autopsy. The number of biopsies was determined that is necessary to achieve the highest possible accuracy in diagnosing pulmonary lesions.
RESULTS: In 591 of 669 biopsies (88.3%), there were correct positive results. The overall accuracy was 87.4%. In 193 of 260 (74.2%) patients, a suspected malignancy was confirmed. In 50 of 260 (19.2%) patients, a benign lesion was correctly diagnosed. Seventeen (6.5%) patients were lost to follow-up. The first, second and third biopsies had cumulative accuracies of 63.6%, 89.2% and 91.5%, respectively (P < 0.02). More biopsies did not show any higher impact on accuracy.
CONCLUSION: For the highest possible accuracy in diagnosing pulmonary lesions by CT-guided core-cut biopsy, at least three usable specimens are recommended to be taken.

Entities:  

Keywords:  CT; lung biopsy; number of biopsies; thoracic lesions

Year:  2010        PMID: 21157523      PMCID: PMC2998930          DOI: 10.4137/ccrpm.s4816

Source DB:  PubMed          Journal:  Clin Med Insights Circ Respir Pulm Med        ISSN: 1179-5484


Introduction

Computed tomography (CT) scan-guided biopsy of thoracic lesions is a widely accepted diagnostic technique.1 Previously, CT scan-guided biopsies were usually performed with fine-needle aspiration and cytological examination to differentiate malignant from benign lesions.2,3 A further development is tissue core biopsy using a cutting needle; this allows histopathological evaluation of the specimen.4 An automated spring-driven cutting needle for tissuecore biopsy has made it easier to obtain satisfactory specimens for histological analysis.5–7 Percutaneous transthoracic biopsy is now more widely performed with helical CT-scanning;2 however, there are other modalities employed for this imaging guided procedure such as fluoroscopy and conventional CT-scanning.1–3 We are unaware of reports in the literature dealing with the number of biopsies in pulmonary lesions required for an accurate histological work up. Therefore, the purpose of our study was to analyse, whether the number of biopsy specimen taken has an impact on diagnostic accuracy at histologic examination.

Materials and Methods

Subjects

From January 1999 to April 2004, 260 patients (mean age of the patients was 64.3 years (range 35–82 years; 158 men and 102 women)) with pulmonary lesions underwent CT-guided core-cut biopsy at our institution. Overall, 669 biopsies were obtained, 1–5 biopsies from each patient at the radiologists’s discretion. None of the patients had severe chronic obstructive disease (COPD), severe emphysema or a coagulopathy. All patients gave written informed consent.

Biopsy Needle

Core-cut biopsy in coaxial technique was performed with a 20-gauge needle (Manan® biopsy needle, Gainsville Florida). The Auto Surecut system (Pro Mag 2.2 Manan®) consists of an outer cutting cannula with a coring point and a trocar with a sharp tip. A closed microsyringe is attached to the outer cutting cannula inside the body of the cutting needle device. The outer cutting cannula is automatically extended to a length of 2.2 cm. At the same time, a vacuum is established in the biopsy canal; the tissue biopsy is obtained by negative pressure at the tip of the outer cannula.

Biopsy Procedure

Before undergoing biopsy all patients had diagnostic helical CT scans (Lightspeed GE, Wisconsin, USA) of the chest with 5 mm slice thickness. These preliminary images were reviewed to plan the level of the needle entry site, patient’s position and the most direct approach for successful biopsy. Patients assumed a supine, prone or lateral position. Experienced interventional radiologists performed all biopsies. An 19 gauge outer guiding cannula was always used to prevent the flexible 20-gauge needle from deviating into the soft tissue. Core-cut biopsies were taken with the Auto Surecut system as described previously. Informed consent was obtained from each patient at least 24 hours before the interventional procedure.

Statistics

All statistical analyses were performed with the statistical software package SPSS version 10.0. The chi square test was applied to analyse dichotomous variables. Statistical significance was considered as P < 0.05.

Results

In 591 of 669 biopsies (88.3%), there were positive results that correlated with and ultimately were confirmed by subsequent surgery, clinical follow-up or autopsy. The accuracy was 87.4%. In 193 of 260 (74.2%) patients, a suspected malignancy was confirmed by surgery. The diagnosis of 13 patients of the surgical group was confirmed additionally by autopsy. In 50 of 260 (19.2%) patients, a benign lesion was correctly diagnosed. They had a follow up period of one year. At the end of one year a CT scan was performed. Seventeen (6.5%) patients were lost to follow-up. The first, second and third biopsies had cumulative accuracies of 63.6%, 89.2% and 91.5%, respectively (P < 0.02) (Fig. 1). In Figures 2 and 3 the number of patients and the number of biopsies that were performed are listed.
Figure 1.

Correlation between number of biopsies and histopathological accuracy of pulmonary nodular lesions. (P < 0.02).

Figure 2.

Number of patients with a histopathological malignancy diagnosed with 1–5 biopsies (first bar) and correct diagnosis after 1–5 biopsies (second bar).

Figure 3.

Number of patients with a histopathological benign diagnosed with 1–5 biopsies (first bar) and correct diagnosis after 1–5 biopsies (second bar).

All histological results are summarized in Figure 3. The median size of pulmonary nodules was 2.8 cm ± 14.9 (range 0.9–6.3 cm). The median lesion depth was 1.2 cm ± 1.4 (range 0–6 cm). Pneumothorax was the most frequent complication: 87 of 260 patients (33.4%) developed a pneumothorax but only 10 (3.8%) patients required a transthoracal chest tube to evacuate the pneumothorax. The second most frequent complication was haemoptysis in 12 (4.6%) patients, none of whom required any further interventional or surgical treatment (Table 1). Otherwise, there were no serious adverse events.
Table 1.

Histological diagnosis of 260 patients with pulmonary lesions. Specimens obtained by CT-guided core-cut biopsy.

Histology
Benign50 (19.2%)
  Harmatoma7
  Wegener’s disease2
  Sarckoidosis2
  Amyloidosis1
  Non-specific*38
Lost to follow-up0 (0%)
Malignant193 (74.2%)
  Adenocarcinoma85
  Non-small cell23
  Squamous33
  Metastasis29
  Undifferentiated carcinoma17
  BAC5
  Lymphoma1
Lost to follow-up17 (6.5%)

In the non-specific group no precise diagnosis was obtained by biopsy, but the benign nature of the lesion was confirmed during follow-up period.

Discussion

Percutaneous biopsy of thoracic lesions has become established as an effective and safe procedure. Successful percutaneous needle biopsy of lung lesions has been applied with excellent results and few complications.8–10 The key to these procedures is the imaging guidance, which allows for the safe passage of a needle into the region of interest in the lung. In most settings, percutaneous biopsy is the first approach to diagnosis. There is little literature dealing with the question of the optimal number of biopsies that should be obtained for the highest possible accuracy, unless a pathologist is on site. In 669 biopsies, we found that the highest possible accuracy was obtained with three suitable specimens. More biopsies did not have any further impact on diagnostic accuracy. We find it of consequence to obtain three specimens in one setting because the operator uses the same approach via the previously positioned outer cannula. More biopsies do not improve the accuracy in the histopathological work-up. A strong reason for this retrospective result cannot be addressed. One fact we stress is the prefabricated way for the multiple biopsies by the outer cannula. Furthermore we state, that there are different numbers of patients in the different biopsy groups which makes the data less comparable. Statistically, we found a strong indication, that at least three biopsies show the best result in terms of accuracy. In our cohort, we observed a complication rate in terms of pneumothorax of 33.4%. Twelve patients needed further treatment with a transthoracal chest tube to evacuate the pneumothorax. Our results correlate quite well with the literature, in which the reported frequency of pneumothorax for CT-guided procedures varies from 8% to 64% (Fig. 2).11–15 The median size of our pulmonary nodules was 2.8 cm ± 14.9 (range 0.9–6.3 cm) and the median lesion depth was 1.2 cm ± 1.4 (range 0–6 cm). A lesion size ≤ 2 cm, a lesion depth of 0.1 to 2 cm and less experienced radiologists are given as the strongest parameters predictive of pneumothorax. The highest bleeding risk correlates with a lesion size ≤ 2 cm, a lesion depth of > 2.1 cm and the absence of pleural effusion.16 Finally, for the power of this study it is important to mention the multi—operative specimens obtaining. The histological results of our cohort also correlate well with those in the literature.17 There is an important advantage to be mentioned in terms of patient’s risks. Obtaining three specimens instead of four or five reduces the risk of bleeding and pneumothorax. The limits of this study are not only the small patient number. The fact, that there a different numbers of patients in the different study groups makes a reliable statement on the absolute necessary number of core cut biopsies in lung lesions difficult. Therefore we stress the fact to design a lager prospective study with better comparable numbers of patients in the different study groups. Nevertheless, we find that CT-guided core-cut biopsy of pulmonary nodules is an effective diagnostic tool for diagnosing pulmonary lesions. On the basis of our data a total number of at least three specimens for every CT-guided core-cut biopsy could be recommended on the condition that each core shows a well preserved barrel for histopathological work up. However, further prospective studies with a greater number of patients and a better distribution of the patients between the different biopsy groups will be helpful for the confirmation of this study data.
Table 2.

Synopsis of complication rate in 260 patients undergoing CT-guided core-cut biopsy.

Complication
Overall99 (38.1%)
Pneumothorax87 (33.4%)
  Transthoracal chest tube10 (3.8%)
Haemoptysis12 (4.6%)
  15 in total

1.  Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules.

Authors:  H Tsukada; T Satou; A Iwashima; T Souma
Journal:  AJR Am J Roentgenol       Date:  2000-07       Impact factor: 3.959

Review 2.  Percutaneous transthoracic needle biopsy.

Authors:  J L Westcott
Journal:  Radiology       Date:  1988-12       Impact factor: 11.105

3.  Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle.

Authors:  O Lucidarme; N Howarth; J F Finet; P A Grenier
Journal:  Radiology       Date:  1998-06       Impact factor: 11.105

4.  Lung lesions: cytologic diagnosis by fine-needle biopsy.

Authors:  J H Stanley; G D Fish; J G Andriole; R P Gobien; W L Betsill; S A Laden; S I Schabel
Journal:  Radiology       Date:  1987-02       Impact factor: 11.105

5.  Direct percutaneous needle aspiration of localized pulmonary lesions: result in 422 patients.

Authors:  J L Westcott
Journal:  Radiology       Date:  1980-10       Impact factor: 11.105

6.  Difficult thoracic lesions: CT-guided biopsy experience in 150 cases.

Authors:  E vanSonnenberg; G Casola; M Ho; C C Neff; R R Varney; G R Wittich; R Christensen; P J Friedman
Journal:  Radiology       Date:  1988-05       Impact factor: 11.105

7.  CT-guided cutting-needle biopsies of selected chest lesions.

Authors:  C H Goralnik; D M O'Connell; S J el Yousef; J R Haaga
Journal:  AJR Am J Roentgenol       Date:  1988-11       Impact factor: 3.959

8.  Coaxial transthoracic fine-needle biopsy in patients with a history of malignant lymphoma.

Authors:  G R Wittich; K W Nowels; R L Korn; R M Walter; D E Lucas; M D Dake; R B Jeffrey
Journal:  Radiology       Date:  1992-04       Impact factor: 11.105

9.  Supplementary tissue-core histology from fine-needle transthoracic aspiration biopsy.

Authors:  R Greene; W M Szyfelbein; R J Isler; P Stark; H Janstsch
Journal:  AJR Am J Roentgenol       Date:  1985-04       Impact factor: 3.959

10.  Percutaneous transthoracic needle aspiration biopsy: a comprehensive review of its current role in the diagnosis and treatment of lung tumors.

Authors:  R C Larscheid; P E Thorpe; W J Scott
Journal:  Chest       Date:  1998-09       Impact factor: 9.410

View more
  4 in total

1.  Diagnostic accuracy and complication rates of percutaneous CT-guided coaxial needle biopsy of pulmonary lesions.

Authors:  Vesna Sarajlic; Sanela Vesnic; Dalma Udovicic-Gagula; Haris Kuric; Okan Akhan
Journal:  Diagn Interv Radiol       Date:  2021-07       Impact factor: 2.630

2.  CT-guided fine-needle ago-biopsy of pulmonary nodules: predictive factors for diagnosis and pneumothorax occurrence.

Authors:  Marco Chiappetta; Francesco Rosella; Valentina Dall'armi; Leda Marina Pomes; Leonardo Petracca Ciavarella; Dania Nachira; Tommaso Pirronti; Stefano Margaritora; Pierluigi Granone
Journal:  Radiol Med       Date:  2016-04-30       Impact factor: 3.469

3.  CT-guided coaxial biopsy of malignant lung lesions: are cores from 20-gauge needle adequate for histologic diagnosis and molecular analysis?

Authors:  Kyongmin S Beck; Tae-Jung Kim; Kyo Young Lee; Young Kyoon Kim; Jin Hyoung Kang; Dae Hee Han
Journal:  J Thorac Dis       Date:  2019-03       Impact factor: 2.895

4.  Coaxial technique-promoted diagnostic accuracy of CT-guided percutaneous cutting needle biopsy for small and deep lung lesions.

Authors:  Lu Zhang; Lei Shi; Zhiping Xiao; Hong Qiu; Ping Peng; Mingsheng Zhang
Journal:  PLoS One       Date:  2018-02-15       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.