Literature DB >> 3357956

Difficult thoracic lesions: CT-guided biopsy experience in 150 cases.

E vanSonnenberg1, G Casola, M Ho, C C Neff, R R Varney, G R Wittich, R Christensen, P J Friedman.   

Abstract

Computed tomography (CT) was used to guide percutaneous fine-needle biopsy in 150 cases of difficult thoracic lesions; in 76 cases, nondiagnostic bronchoscopy (n = 62) and fluoroscopic biopsy (n = 14) had previously been performed. CT was indicated for guidance when the pulmonary or pleural lesions were small (0.3-2.5 cm); in a juxta-vascular location, either hilar or mediastinal; not seen or poorly visualized on conventional radiographs; or considered inaccessible. A diagnosis was made in 124 of 150 cases (82.7%) (107 of 124 malignant and 17 of 26 benign lesions), including 86 of 107 lung nodules (80.4%), 28 of 31 mediastinal lesions (90.3%), and ten of 12 pleural masses (83.3%). Complications included pneumothorax (n = 64), hemoptysis (n = 5), hemothorax (n = 2), and pericarditis (n = 1). The high rate of pneumothorax, its treatment, and advantages of its immediate radiologic management are discussed. Use of CT guidance considerably expands the scope of thoracic lesions amenable to percutaneous biopsy.

Entities:  

Mesh:

Year:  1988        PMID: 3357956     DOI: 10.1148/radiology.167.2.3357956

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  57 in total

1.  Atrial fibrillation and pneumothorax after transthoracic needle lung biopsy.

Authors:  Alexander Liu; Iain Southern; Edward Nicol
Journal:  BMJ Case Rep       Date:  2012-01-18

2.  Neuromuscular blockade with acute respiratory failure in a patient receiving cibenzoline.

Authors:  T Similowski; C Straus; V Attali; F Girard; F Philippe; G Deray; D Thomas; J P Derenne
Journal:  Thorax       Date:  1997-06       Impact factor: 9.139

3.  Delayed pneumothorax after CT-guided percutaneous fine needle aspiration lung biopsy.

Authors:  Z C Traill; F V Gleeson
Journal:  Thorax       Date:  1997-06       Impact factor: 9.139

4.  Guidelines for radiologically guided lung biopsy.

Authors:  A Manhire; M Charig; C Clelland; F Gleeson; R Miller; H Moss; K Pointon; C Richardson; E Sawicka
Journal:  Thorax       Date:  2003-11       Impact factor: 9.139

5.  Transthoracic needle biopsy.

Authors:  Katherine R Birchard
Journal:  Semin Intervent Radiol       Date:  2011-03       Impact factor: 1.513

Review 6.  CT-guided transthoracic needle biopsy.

Authors:  D Gardner; E vanSonnenberg; H B D'Agostino; G Casola; S Taggart; S May
Journal:  Cardiovasc Intervent Radiol       Date:  1991 Jan-Feb       Impact factor: 2.740

7.  Percutaneous biopsy of mediastinal tumours under sonographic guidance.

Authors:  K Wernecke
Journal:  Thorax       Date:  1991-03       Impact factor: 9.139

8.  Single pass aspiration biopsy for repeat sampling--evaluation in 726 cases: technical note.

Authors:  K C Klose; A Böcking
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Mar-Apr       Impact factor: 2.740

9.  Newly developed application system for CT-guided puncture based on multidetector row CT without CT fluoroscopy.

Authors:  Toshiyuki Irie; Masashi Kuramochi
Journal:  Radiat Med       Date:  2007-10-26

10.  Diagnostic performance of percutaneous lung biopsy using automated biopsy needles under CT-fluoroscopic guidance for ground-glass opacity lesions.

Authors:  T Yamagami; R Yoshimatsu; H Miura; K Yamada; A Takahata; T Matsumoto; T Hasebe
Journal:  Br J Radiol       Date:  2013-02       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.