Literature DB >> 3797651

Lung lesions: cytologic diagnosis by fine-needle biopsy.

J H Stanley, G D Fish, J G Andriole, R P Gobien, W L Betsill, S A Laden, S I Schabel.   

Abstract

Small-bore (22- or 23-gauge) needles were used to aspirate 458 lung masses. Sensitivity for the detection of malignancy by this method was 96.6% (312 of 323 patients); accuracy was 98.7%. Surgical confirmation was available for comparison in over half of patients with malignancy. Histologic reclassification of malignancy occurred in only 6.1% of patients, with significant misclassification (misdiagnosis of small cell carcinoma) occurring in only two instances. One hundred thirteen of 117 nonmalignant conditions were properly categorized, with an overall specificity of 96.6%. No major complication occurred. While several recent studies have stressed the advantage of using larger needles, to overcome the limitation of smaller aspiration needles that provide only cytologic material, small-needle aspiration appears to be a safe, reliable, and accurate means for diagnosing lung lesions.

Entities:  

Mesh:

Year:  1987        PMID: 3797651     DOI: 10.1148/radiology.162.2.3797651

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  25 in total

1.  Neuromuscular blockade with acute respiratory failure in a patient receiving cibenzoline.

Authors:  T Similowski; C Straus; V Attali; F Girard; F Philippe; G Deray; D Thomas; J P Derenne
Journal:  Thorax       Date:  1997-06       Impact factor: 9.139

2.  Delayed pneumothorax after CT-guided percutaneous fine needle aspiration lung biopsy.

Authors:  Z C Traill; F V Gleeson
Journal:  Thorax       Date:  1997-06       Impact factor: 9.139

3.  Guidelines for radiologically guided lung biopsy.

Authors:  A Manhire; M Charig; C Clelland; F Gleeson; R Miller; H Moss; K Pointon; C Richardson; E Sawicka
Journal:  Thorax       Date:  2003-11       Impact factor: 9.139

4.  Single pass aspiration biopsy for repeat sampling--evaluation in 726 cases: technical note.

Authors:  K C Klose; A Böcking
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Mar-Apr       Impact factor: 2.740

5.  Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules.

Authors:  Massimo De Filippo; Luca Saba; Giorgio Concari; Rita Nizzoli; Lilia Ferrari; Marcello Tiseo; Andrea Ardizzoni; Nicola Sverzellati; Ilaria Paladini; Chiara Ganazzoli; Luca Maria Sconfienza; Giampaolo Carrafiello; Luca Brunese; Eugenio Annibale Genovese; Luca Ampollini; Paolo Carbognani; Michele Rusca; Maurizio Zompatori; Cristina Rossi
Journal:  Radiol Med       Date:  2013-07-25       Impact factor: 3.469

Review 6.  The Society for Translational Medicine: indications and methods of percutaneous transthoracic needle biopsy for diagnosis of lung cancer.

Authors:  Qinghua Zhou; Jingsi Dong; Jie He; Deruo Liu; David H Tian; Shugeng Gao; Shanqing Li; Lunxu Liu; Jianxing He; Yunchao Huang; Shidong Xu; Weimin Mao; Qunyou Tan; Chun Chen; Xiaofei Li; Zhu Zhang; Gening Jiang; Lin Xu; Lanjun Zhang; Jianhua Fu; Hui Li; Qun Wang; Lijie Tan; Danqing Li; Qinghua Zhou; Xiangning Fu; Zhongmin Jiang; Haiquan Chen; Wentao Fang; Xun Zhang; Yin Li; Ti Tong; Zhentao Yu; Yongyu Liu; Xiuyi Zhi; Tiansheng Yan; Xingyi Zhang; Roberto F Casal; Eugenio Pompeo; Angelo Carretta; Marc Riquet; Ottavio Rena; Pierre-Emmanuel Falcoz; Hisashi Saji; Ali Zamir Khan; Jose Luis Danguilan; Diego Gonzalez-Rivas; Nicolas Guibert; Chengchu Zhu; Jianfei Shen
Journal:  J Thorac Dis       Date:  2018-09       Impact factor: 2.895

Review 7.  Ultrathin needle (25 G) aspiration lung biopsy: diagnostic accuracy and complication rates.

Authors:  Anastasia Oikonomou; Frederick R Matzinger; Jean M Seely; Carole J Dennie; Peter J Macleod
Journal:  Eur Radiol       Date:  2003-10-09       Impact factor: 5.315

8.  Number of biopsies in diagnosing pulmonary nodules.

Authors:  M Wehrschuetz; E Wehrschuetz; H R Portugaller
Journal:  Clin Med Insights Circ Respir Pulm Med       Date:  2010-07-08

9.  Predictive success factors for CT-guided fine needle aspiration biopsy of pulmonary lesions.

Authors:  Marcos Duarte Guimarães; Rubens Chojniak; Jefferson L Gross; Almir G V Bitencourt
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

10.  Tumor-like pulmonary sarcoidosis diagnosed by CT-guided transthoracic lung biopsy.

Authors:  N Sidiropoulou; P Filippousis; S Apostolopoulou; I Tsangaridou; L Thanos
Journal:  Cases J       Date:  2009-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.