Literature DB >> 33769291

Diagnostic accuracy and complication rates of percutaneous CT-guided coaxial needle biopsy of pulmonary lesions.

Vesna Sarajlic1, Sanela Vesnic1, Dalma Udovicic-Gagula2, Haris Kuric1, Okan Akhan3.   

Abstract

PURPOSE: The aim of this retrospective study was to evaluate and compare diagnostic accuracy and complication rates of percutaneous computed tomography (CT)-guided biopsies of pulmonary lesions 10-35 mm, 35-50 mm, and >50 mm, using the coaxial biopsy technique.
METHODS: Over a 4-year period, 235 lung biopsies were performed using the coaxial biopsy technique with 18G semi-automated true-cut needle. There were 163 (69.4%) male and 72 (30.6%) female patients, with a mean age of 64.01±9.18 years (18-85 years). The mean lesion size was 59.6±29.3 mm. The lesions were stratified into three groups according to size: lesions <35 mm (n=42, 17.9%), lesions 35-50 mm (n=53, 22.5%), and lesions >50 mm (n=140, 59.6%). Diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for all biopsies, and for each group separately, as well as the incidence of complications.
RESULTS: The overall diagnostic accuracy was 95.4%, with 95.52% sensitivity, 100% specificity, 100% PPV, and 47.37% NPV. For lesions <35 mm, diagnostic accuracy, sensitivity, and PPV were 100%. The lowest diagnostic accuracy was 93.9% in lesions >50 mm, with 93.65% sensitivity, 100% specificity, 100% PPV, and 42.86% NPV. An adequate sample was obtained in 219 core biopsies (93.2%), while 16 biopsies (6.8%) were nondiagnostic due to necrosis (4.25%) and insufficient biopsy material (2.55%). The most frequent complication was minor pneumothorax, which was seen at a rate of 19.1%; pneumothorax requiring chest tube placement occurred in 3 patients (1.3%).
CONCLUSION: Diagnostic accuracy decreased with increasing lesion size. On the other hand, complication rates were higher in smaller lesions, more distanced from the pleura.

Entities:  

Year:  2021        PMID: 33769291      PMCID: PMC8289424          DOI: 10.5152/dir.2021.20844

Source DB:  PubMed          Journal:  Diagn Interv Radiol        ISSN: 1305-3825            Impact factor:   2.630


  21 in total

1.  Quality improvement guidelines for percutaneous needle biopsy.

Authors:  Sanjay Gupta; Michael J Wallace; John F Cardella; Sanjoy Kundu; Donald L Miller; Steven C Rose
Journal:  J Vasc Interv Radiol       Date:  2010-03-20       Impact factor: 3.464

2.  Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses.

Authors:  Siri Lagethon Heck; Peter Blom; Audun Berstad
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

3.  Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors.

Authors:  F Laurent; P Michel; V Latrabe; M Tunon de Lara; R Marthan
Journal:  AJR Am J Roentgenol       Date:  1999-04       Impact factor: 3.959

4.  The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy.

Authors:  Joshua D Kuban; Alda L Tam; Steven Y Huang; Joe E Ensor; Asher S Philip; Geraldine J Chen; Judy Ahrar; Ravi Murthy; Rony Avritscher; David C Madoff; Armeen Mahvash; Kamran Ahrar; Michael J Wallace; Arun C Nachiappan; Sanjay Gupta
Journal:  Cardiovasc Intervent Radiol       Date:  2015-04-30       Impact factor: 2.740

5.  Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors.

Authors:  Anna Moreland; Eitan Novogrodsky; Lynn Brody; Jeremy Durack; Joseph Erinjeri; George Getrajdman; Stephen Solomon; Hooman Yarmohammadi; Majid Maybody
Journal:  Eur Radiol       Date:  2016-01-19       Impact factor: 5.315

6.  Number of biopsies in diagnosing pulmonary nodules.

Authors:  M Wehrschuetz; E Wehrschuetz; H R Portugaller
Journal:  Clin Med Insights Circ Respir Pulm Med       Date:  2010-07-08

7.  Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures.

Authors:  Kee-Min Yeow; Pei-Kwei Tsay; Yun-Chung Cheung; Kar-Wai Lui; Kuang-Tse Pan; Andy Shau-Bin Chou
Journal:  J Vasc Interv Radiol       Date:  2003-05       Impact factor: 3.464

8.  Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy.

Authors:  Serif Beslic; Fuad Zukic; Selma Milisic
Journal:  Radiol Oncol       Date:  2012-01-02       Impact factor: 2.991

9.  Diagnostic Accuracy of CT-Guided Transthoracic Needle Biopsy for Solitary Pulmonary Nodules.

Authors:  Wen Yang; Wenkui Sun; Qian Li; Yanwen Yao; Tangfeng Lv; Junli Zeng; Wenjun Liang; Xiaojun Zhou; Yong Song
Journal:  PLoS One       Date:  2015-06-25       Impact factor: 3.240

10.  Computed tomography-guided percutaneous cutting needle biopsy for small (≤ 20 mm) lung nodules.

Authors:  Guang-Chao Li; Yu-Fei Fu; Wei Cao; Yi-Bing Shi; Tao Wang
Journal:  Medicine (Baltimore)       Date:  2017-11       Impact factor: 1.889

View more
  1 in total

1.  Comparison of CT-Guided Core Needle Biopsy in Pulmonary Ground-Glass and Solid Nodules Based on Propensity Score Matching Analysis.

Authors:  Wenting An; Hanfei Zhang; Binchen Wang; Feiyang Zhong; Shan Wang; Meiyan Liao
Journal:  Technol Cancer Res Treat       Date:  2022 Jan-Dec
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.